Vaginal Hemorrhage From Transobturator Sling Controlled With QuikClot Combat Gauze

被引:9
作者
Patel, Samit A. [1 ]
Martin, Matthew [1 ]
Chamales, Ingrid [1 ]
机构
[1] Madigan Army Med Ctr, Tacoma, WA 98431 USA
关键词
D O I
10.7205/MILMED-D-11-00429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 42-year-old woman underwent an outside-in transobturator sling procedure, with subsequent venous hemorrhage. Two rolls of Combat Gauze were placed intravaginally and taken out on postoperative day 2 with good hemostasis. Despite careful technique, hemorrhage is a known complication of midurethral slings. Advanced hemostatic dressings may provide hemorrhage control and avoid the need for surgical intervention. After an extensive literature review, we present the first case of QuikClot Combat Gauze used as a hemostatic agent due to vaginal hemorrhage.
引用
收藏
页码:997 / 998
页数:2
相关论文
共 9 条
  • [1] Haemorrhage and nerve damage as complications of TVT-O procedure: case report and literature review
    Atassi, Ziad
    Reich, Andreas
    Rudge, Alexandra
    Kreienberg, Rolf
    Flock, Felix
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2008, 277 (02) : 161 - 164
  • [2] Transobturator tape compared with tension-free vaginal tape for the treatment of stress urinary incontinence
    Barber, Matthew D.
    Kleeman, Steven
    Karram, Mickey M.
    Paraiso, Marie Fidela R.
    Walters, Mark D.
    Fasavada, Sandip
    Ellerkmann, Mark
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 111 (03) : 611 - 621
  • [3] Complications associated with transobturator sling procedures
    Boyles, Sarah Hamilton
    Edwards, Renee
    Gregory, William
    Clark, Amanda
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 (01) : 19 - 22
  • [4] Military applications of novel hemostatic devices
    Gordy, Stephanie D.
    Rhee, Peter
    Schreiber, Martin A.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2011, 8 (01) : 41 - 47
  • [5] Retropubic compared with transobturator tape placement in treatment of urinary incontinence - A randomized controlled trial
    Laurikainen, Eija
    Valpas, Antti
    Kivela, Aarre
    Kalliola, Tuomo
    Rinne, Kirsi
    Takala, Teuvo
    Nilsson, Carl Gustaf
    [J]. OBSTETRICS AND GYNECOLOGY, 2007, 109 (01) : 4 - 11
  • [6] TVT and TVT-Obturator: Comparison of two operative procedures
    Neuman, Menahem
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2007, 131 (01): : 89 - 92
  • [7] Ottem Derek, 2007, Can J Urol, V14, P3678
  • [8] Comparison of retropubic vs transobturator approach to midurethral slings: a systematic review and meta-analysis
    Sung, Vivian W.
    Schleinitz, Mark D.
    Rardin, Charles R.
    Ward, Renee M.
    Myers, Deborah L.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (01) : 3 - 11
  • [9] Anatomy of the obturator region: relations to a trans-obturator sling
    Whiteside, JL
    Walters, MD
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2004, 15 (04) : 223 - 226