Preparation of Ag/NaA zeolite modified carbon paste electrode as a DNA biosensor

被引:31
作者
Azizi, Seyed Naser [1 ]
Ranjbar, Sara [1 ]
Raoof, Jahan Bakhsh [2 ]
Hamidi-Asl, Ezat [2 ]
机构
[1] Univ Mazandaran, Fac Chem, Analyt Div, Babol Sar, Iran
[2] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Eletroanalyt Chem Res Lab, Babol Sar, Iran
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2013年 / 181卷
关键词
Methylene blue; DNA hybridization; Ag/NaA zeolite; Modified carbon paste electrode; DNA biosensor; ASSEMBLED ALKANETHIOL MONOLAYER; PEPTIDE NUCLEIC-ACID; METHYLENE-BLUE; ELECTROCHEMICAL DETECTION; OLIGONUCLEOTIDE; GENE; INDICATOR; BEHAVIOR; ASSAY;
D O I
10.1016/j.snb.2013.02.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, we reported a method for synthesis of NaA zeolite. NaA zeolite has been successfully prepared within 30 min by microwave heating without using any conventional hydrothermal treatment and due to the exchange process the silver-loaded NaA microsized zeolites was produced. The synthesized zeolite was characterized using X-ray diffraction, scanning electronic microscopy and FT-IR techniques. The modified carbon paste electrode was prepared by incorporation of Ag(I) zeolite in the carbon paste matrix. Differential pulse voltammetry (DPV) was employed for development of electrochemical DNA hybridization biosensors based on Ag/NaA zeolite modified carbon paste electrode (Ag/ZMCPE) and methylene blue (MB) as electroactive label was used. The sensors rely on immobilization of a 15-mer single stranded oligonucleotide probe for detection of target DNA, as a model. The hybridization event was evaluated by DPV. Moreover, Ag/ZMCPE showed better advantages than NaA zeolite modified carbon paste electrode (ZMCPE). Under optimized experimental conditions, limit of detection was calculated 4.00 x 10(-12) M. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 35 条
  • [1] Synthesis of zeolites NaA and analcime using rice husk ash as silica source without using organic template
    Azizi, Seyed Naser
    Yousefpour, Maryam
    [J]. JOURNAL OF MATERIALS SCIENCE, 2010, 45 (20) : 5692 - 5697
  • [2] Electrochemical detection of miRNA-222 by use of a magnetic bead-based bioassay
    Bettazzi, Francesca
    Hamid-Asl, Ezat
    Esposito, Carla Lucia
    Quintavalle, Cristina
    Formisano, Nello
    Laschi, Serena
    Catuogno, Silvia
    Iaboni, Margherita
    Marrazza, Giovanna
    Mascini, Marco
    Cerchia, Laura
    De Franciscis, Vittorio
    Condorelli, Gerolama
    Palchetti, Ilaria
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (2-3) : 1025 - 1034
  • [3] Guerra SV, 1998, ELECTROANAL, V10, P462, DOI 10.1002/(SICI)1521-4109(199806)10:7<462::AID-ELAN462>3.0.CO
  • [4] 2-F
  • [5] Hamidi-Asl E., 2012, SENS MICROSYST, V109, P37, DOI DOI 10.1007/978-1-4614-0935-9_7
  • [6] Immobilization and voltammetric detection of human interleukine-2 gene on the pencil graphite electrode
    Hejazi, M. S.
    Alipour, E.
    Pournaghi-Azar, M. H.
    [J]. TALANTA, 2007, 71 (04) : 1734 - 1740
  • [7] Electrochemical detection of short sequences of hepatitis C 3a virus using a peptide nucleic acid-assembled gold electrode
    Hejazi, M. S.
    Pournaghi-Azar, M. H.
    Ahour, F.
    [J]. ANALYTICAL BIOCHEMISTRY, 2010, 399 (01) : 118 - 124
  • [8] Brilliant cresyl blue as electroactive indicator in electrochemical DNA oligonucleotide sensors
    Hejazi, Mohammad Saeid
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Golabi, Seyd Mehdi
    Asl, Ezat Hamidi
    [J]. BIOELECTROCHEMISTRY, 2010, 78 (02) : 141 - 146
  • [9] Jiang YX, 1999, ELECTROANAL, V11, P254, DOI 10.1002/(SICI)1521-4109(199904)11:4<254::AID-ELAN254>3.3.CO
  • [10] 2-F