Magnetic Resonace-Based Attenuation Correction for Micro-Single-Photon Emission Computed Tomography

被引:7
|
作者
Keereman, Vincent
Fierens, Yves
Vanhove, Christian
Lahoutte, Tony
Vandenberghe, Stefaan
机构
[1] Ghent Univ IBBT IBiTech, Dept Elect & Informat Syst, MEDISIP, Ghent, Belgium
[2] UZ Brussel, In Vivo Cellular & Mol Imaging Ctr, Radiol BEFY, Brussels, Belgium
[3] UZ Brussel, Dept Nucl Med, Brussels, Belgium
来源
MOLECULAR IMAGING | 2012年 / 11卷 / 02期
关键词
SUBSETS EXPECTATION MAXIMIZATION; PINHOLE SPECT; CT; PET/MRI; PHANTOM; QUANTIFICATION; RECONSTRUCTION; COEFFICIENTS; ACCURACY; IMAGES;
D O I
10.2310/7290.2011.00036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Attenuation correction is necessary for quantification in micro-single-photon emission computed tomography (micro-SPECT). In general, this is done based on micro-computed tomographic (micro-CT) images. Derivation of the attenuation map from magnetic resonance (MR) images is difficult because bone and lung are invisible in conventional MR images and hence indistinguishable from air. An ultrashort echo time (UTE) sequence yields signal in bone and lungs. Micro-SPECT, micro-CT, and MR images of 18 rats were acquired. Different tracers were used: hexamethylpropyleneamine oxime (brain), dimercaptosuccinic acid (kidney), colloids (liver and spleen), and macroaggregated albumin (lung). The micro-SPECT images were reconstructed without attenuation correction, with micro-CT-based attenuation maps, and with three MR-based attenuation maps: uniform, non-UTE-MR based (air, soft tissue), and UTE-MR based (air, lung, soft tissue, bone). The average difference with the micro-CT-based reconstruction was calculated. The UTE-MR-based attenuation correction performed best, with average errors <= 8% in the brain scans and <= 3% in the body scans. It yields nonsignificant differences for the body scans. The uniform map yields errors of <= 6% in the body scans. No attenuation correction yields errors >= 15% in the brain scans and >= 25% in the body scans. Attenuation correction should always be performed for quantification. The feasibility of MR-based attenuation correction was shown. When accurate quantification is necessary, a UTE-MR-based attenuation correction should be used.
引用
收藏
页码:155 / 165
页数:11
相关论文
共 50 条
  • [31] The Influence Of Attenution Correction On The Image Quality In Single Photon Emission Computed Tomography
    Rep, S.
    Frelih, N.
    Lezaic, L.
    Zibert, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S871 - S872
  • [32] SCATTER CORRECTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT)
    BETTINARDI, V
    GILARDI, MC
    MILANESI, L
    GERUNDINI, P
    FAZIO, F
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1987, 31 (01): : 25 - 25
  • [33] AN ANALYTICAL APPROACH TO SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY WITH THE ATTENUATION EFFECT
    SOUSSALINE, FP
    CAO, A
    LECOQ, G
    RAYNAUD, C
    KELLERSHOHN, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1982, 7 (11): : 487 - 493
  • [34] Single-photon emission computed tomography/computed tomography in endocrinology
    Krausz, Yodphat
    Israel, Ora
    SEMINARS IN NUCLEAR MEDICINE, 2006, 36 (04) : 267 - 274
  • [35] Is Single-Photon Emission Computed Tomography/Computed Tomography Superior to Single-Photon Emission Computed Tomography in Assessing Unilateral Condylar Hyperplasia?
    Liu, Pingan
    Shi, Jun
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (06) : 1279.e1 - 1279.e7
  • [36] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Marvin Grossmann
    Andreas A. Giannopoulos
    Fabiola A. Bechtiger
    Michael Messerli
    Moritz Schwyzer
    Dominik C. Benz
    Ken Kudura
    Catherine Gebhard
    Christoph Gräni
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    Journal of Nuclear Cardiology, 2020, 27 : 228 - 237
  • [37] Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
    Grossmann, Marvin
    Giannopoulos, Andreas A.
    Bechtiger, Fabiola A.
    Messerli, Michael
    Schwyzer, Moritz
    Benz, Dominik C.
    Kudura, Ken
    Gebhard, Catherine
    Graeni, Christoph
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (01) : 228 - 237
  • [38] Magnetic resonance imaging, positron emission tomography, and single-photon-emission computed tomography in epilepsy
    Chong, BW
    Shelton, DK
    WESTERN JOURNAL OF MEDICINE, 1996, 165 (1-2): : 53 - 54
  • [39] Positron emission computed tomography/single photon emission computed tomography in Parkinson disease
    Yao Nian-Ting
    Zheng Qian
    Xu Zi-Qian
    Yin Jian-Hong
    Lu Lin-Guang
    Zuo Qi
    Yang Su
    Zhang Chun-Lin
    Jiao Ling
    中华医学杂志英文版, 2020, 133 (12) : 1448 - 1455
  • [40] Positron emission computed tomography/single photon emission computed tomography in Parkinson disease
    Yao, Nian-Ting
    Zheng, Qian
    Xu, Zi-Qian
    Yin, Jian-Hong
    Lu, Lin-Guang
    Zuo, Qi
    Yang, Su
    Zhang, Chun-Lin
    Jiao, Ling
    CHINESE MEDICAL JOURNAL, 2020, 133 (12) : 1448 - 1455