Experimental and numerical investigation on exposed RCFST column-base Joint

被引:5
作者
Mou, Ben [2 ]
Yan, Xingchen [1 ]
Qiao, Qiyun [3 ]
Zhou, Wanqiu [1 ]
机构
[1] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
[2] Hubei Univ Technol, Sch Civil Engn Architecture & Environm, Wuhan, Peoples R China
[3] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100124, Peoples R China
关键词
axial force ratio; column base joint; finite element analysis; parametric analysis; ultrahigh-strength steel bar; CFST COLUMN; SEISMIC PERFORMANCE; PLATE CONNECTIONS; SHEAR BEHAVIOR; STEEL; DESIGN;
D O I
10.12989/scs.2022.45.5.749
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the seismic performance of exposed RCFST column--base joints, in which the high--strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width--thickness ratio (D/t), axial force ratio (n), shear--span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column--base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column--base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.
引用
收藏
页码:749 / 766
页数:18
相关论文
共 37 条
  • [1] Performance of new CFST square column-to-foundation connections for cyclic loads
    Abbas, Husain
    Siddiqui, Nadeem A.
    Khateeb, Baha M.
    Almusallam, Tarek H.
    Al-Salloum, Yousef A.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185
  • [2] Anchored blind bolted composite connection to a concrete filled steel tubular column
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Mirza, Olivia
    [J]. STEEL AND COMPOSITE STRUCTURES, 2017, 23 (01) : 115 - 130
  • [3] [Anonymous], 2002, GB50010 MIN HOUS URB
  • [4] [Anonymous], 2014, STANDARD USERS MANUA
  • [5] [Anonymous], 2010, DESIGN RECOMMENDATIO
  • [6] [Anonymous], 2008, Recommendations for design and construction of concrete filled steel tubular structures
  • [7] Rotational behavior of exposed column bases with different base plate thickness
    Cui, Yao
    Wang, Fengzhi
    Li, Hao
    Yamada, Satoshi
    [J]. STEEL AND COMPOSITE STRUCTURES, 2019, 32 (04) : 497 - 507
  • [8] Shear behavior of exposed column base connections
    Cui, Yao
    [J]. STEEL AND COMPOSITE STRUCTURES, 2016, 21 (02) : 357 - 371
  • [9] Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns
    Ding, Fa-xing
    Pan, Zhi-cheng
    Liu, Peng
    Huang, Shi-jian
    Luo, Liang
    Zhang, Tao
    [J]. STEEL AND COMPOSITE STRUCTURES, 2020, 36 (04) : 447 - 462
  • [10] Capacity of exposed column base connections subjected to uniaxial and biaxial bending moments
    Fasaee, Mohammad Ali Khaksar
    Banan, Mohammad Reza
    Ghazizadeh, Sina
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 361 - 370