Experimentally validated Raman Monte Carlo simulation for a cuboid object to obtain Raman spectroscopic signatures for hidden material

被引:16
|
作者
Periyasamy, Vijitha [1 ]
Sil, Sanchita [2 ,3 ]
Dhal, Gagan [2 ]
Ariese, Freek [2 ]
Umapathy, Siva [2 ]
Pramanik, Manojit [4 ]
机构
[1] Indian Inst Sci, Dept Elect Engn, Bangalore 560012, Karnataka, India
[2] Indian Inst Sci, Dept Inorgan Phys Chem, Laser Spect Grp, Bangalore 560012, Karnataka, India
[3] Deputat High Energy Mat Res Lab, Pune, Maharashtra, India
[4] Nanyang Technol Univ, Sch Chem & Biomed Engn, Biomed Imaging Lab, Singapore 637459, Singapore
关键词
Monte Carlo simulation; Raman spectroscopy; photon migration; multiple scattering; explosive detection; IN-VIVO; SCATTERING; TOMOGRAPHY; MICROSPECTROSCOPY; LIGHT;
D O I
10.1002/jrs.4709
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In conventional Raman spectroscopic measurements of liquids or surfaces the preferred geometry for detection of the Raman signal is the backscattering (or reflection) mode. For non-transparent layered materials, sub-surface Raman signals have been retrieved using spatially offset Raman spectroscopy (SORS), usually with light collection in the same plane as the point of excitation. However, as a result of multiple scattering in a turbid medium, Raman photons will be emitted in all directions. In this study, Monte Carlo simulations for a three-dimensional layered sample with finite geometry have been performed to confirm the detectability of Raman signals at all angles and at all sides of the object. We considered a non-transparent cuboid container (high density polyethylene) with explosive material (ammonium nitrate) inside. The simulation results were validated with experimental Raman intensities. Monte Carlo simulation results reveal that the ratio of sub-surface to surface signals improves at geometries other than backscattering. In addition, we demonstrate through simulations the effects of the absorption and scattering coefficients of the layers, and that of the diameter of the excitation beam. The advantage of collecting light from all possible 4 angles, over other collection modes, is that this technique is not geometry specific and molecular identification of layers underneath non-transparent surfaces can be obtained with minimal interference from the surface layer. To what extent all sides of the object will contribute to the total signal will depend on the absorption and scattering coefficients and the physical dimensions. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:669 / 676
页数:8
相关论文
共 12 条
  • [1] Experimental validation of a spectroscopic Monte Carlo light transport simulation technique and Raman scattering depth sensing analysis in biological tissue
    Akbarzadeh, Alireza
    Edjlali, Ehsan
    Sheehy, Guillaume
    Selb, Juliette
    Agarwal, Rajeev
    Weber, Jessie
    Leblond, Frederic
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (10)
  • [2] Raman Monte Carlo Simulation for light propagation for tissue with embedded objects
    Periyasamy, Vijitha
    Jaafar, Humaira Bte
    Pramanik, Manojit
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXIX, 2018, 10492
  • [3] Monte Carlo simulation of Raman confocal spectroscopy of beta-carotene solution
    Krasnikov, I.
    Seteikin, A.
    Roth, B.
    Meinhardt-Wollweber, M.
    ASIA-PACIFIC CONFERENCE ON FUNDAMENTAL PROBLEMS OF OPTO- AND MICROELECTRONICS, 2017, 10176
  • [4] Chemical Identification from Raman Peak Classification Using Fuzzy Logic and Monte Carlo Simulation
    Angelini, Federico
    Santoro, Simone
    Colao, Francesco
    CHEMOSENSORS, 2022, 10 (08)
  • [5] Experimentally validated Monte Carlo simulation of an XtRa-NaI(Tl) Compton Suppression System response
    Savva, Marilia
    Anagnostakis, Marios
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 555 - 557
  • [6] Additive simulation of Raman light scattering from skin cancer using the Monte Carlo method
    Matveeva, Irina A.
    Myakinin, Oleg O.
    Khristoforova, Yulia A.
    Bratchenko, Ivan A.
    Moryatov, Alexander A.
    Kozlov, Sergey, V
    Zakharov, Valery P.
    TISSUE OPTICS AND PHOTONICS, 2020, 11363
  • [7] Monte Carlo simulation of the influence of internal optical absorption on the external Raman signal for biological samples
    Krasnikov, Ilya
    Suhr, Christian
    Seteikin, Alexey
    Meinhardt-Wollweber, Merve
    Roth, Bernhard
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (05) : 877 - 882
  • [8] Monte Carlo simulation of in vivo Raman spectral measurements of human skin with a multi-layered tissue optical model
    Wang, Shuang
    Zhao, Jianhua
    Lui, Harvey
    He, Qingli
    Bai, Jintao
    Zeng, Haishan
    JOURNAL OF BIOPHOTONICS, 2014, 7 (09) : 703 - 712
  • [9] Optimizing number of Raman spectra using an artificial neural network guided Monte Carlo simulation approach to analyze human cortical bone
    Unal, Safa
    Mayda, Murat
    Nyman, Jeffry S.
    Unal, Mustafa
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 325
  • [10] Solubility study of binary systems containing sulfur dioxide and water: A combination of Raman spectroscopy and Monte Carlo molecular simulation
    Saadallah, Khouloud
    Lachet, Veronique
    Creton, Benoit
    Caumon, Marie-Camille
    Randi, Aurelien
    Sterpenich, Jerome
    FLUID PHASE EQUILIBRIA, 2023, 574