Detection and Prediction of Bioprosthetic Aortic Valve Degeneration

被引:116
|
作者
Cartlidge, Timothy R. G. [1 ]
Doris, Mhairi K. [1 ]
Sellers, Stephanie L. [2 ]
Pawade, Tania A. [1 ]
White, Audrey C. [1 ]
Pessotto, Renzo [1 ]
Kwiecinski, Jacek [1 ]
Fletcher, Alison [3 ]
Alcaide, Carlos [1 ]
Lucatelli, Christophe [3 ]
Densem, Cameron [4 ]
Rudd, James H. F. [5 ]
van Beek, Edwin J. R. [3 ]
Tavares, Adriana [1 ]
Virmani, Renu [6 ]
Berman, Daniel [7 ]
Leipsic, Jonathon A. [2 ]
Newby, David E. [1 ]
Dweck, Marc R. [1 ]
机构
[1] Univ Edinburgh, British Heart Fdn, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Queens Med Res Inst, Edinburgh Imaging Facil, Edinburgh, Midlothian, Scotland
[3] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC, Canada
[4] Papworth Hosp NHS Fdn Trust, Dept Cardiol, Cambridge, England
[5] Univ Cambridge, Div Cardiovasc Med, Cambridge, England
[6] CVPath Inst, Gaithersburg, MD USA
[7] Cedars Sinai Heart Inst, Los Angeles, CA USA
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
aortic valve replacement; bioprosthetic valve degeneration; calcification; histology; positron emission tomography; SUBCLINICAL LEAFLET THROMBOSIS; PROSTHETIC HEART-VALVES; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; FLUORIDE UPTAKE; TRANSCATHETER; ECHOCARDIOGRAPHY; RECOMMENDATIONS; CALCIFICATION; REPLACEMENT;
D O I
10.1016/j.jacc.2018.12.056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences. OBJECTIVES The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction. METHODS Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up. RESULTS All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: -0.05 to 0.16] ms(-1)/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e. g., change in peak velocity, r <1/4> 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (targetto- background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction. CONCLUSIONS 18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276) (J Am Coll Cardiol 2019; 73: 1107-19) (c) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons. org/licenses/by/4.0/).
引用
收藏
页码:1107 / 1119
页数:13
相关论文
共 50 条
  • [41] Bioprosthetic Aortic Valve Thrombosis and Literature Review
    Radovanovic, Milan
    Nordstrom, Charles W.
    Hanna, Richard D.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (08)
  • [42] Very late bioprosthetic aortic valve thrombosis
    Balakrishnan, Kuhendra
    Herman, Brian
    Koshy, George
    BMJ CASE REPORTS, 2019, 12 (05)
  • [43] Acute Modification of Hemodynamic Forces in Patients with Severe Aortic Stenosis after Transcatheter Aortic Valve Implantation
    Vairo, Alessandro
    Zaccaro, Lorenzo
    Ballatore, Andrea
    Airale, Lorenzo
    D'Ascenzo, Fabrizio
    Alunni, Gianluca
    Conrotto, Federico
    Scudeler, Luca
    Mascaretti, Daniela
    Miccoli, Davide
    Torre, Michele La
    Rinaldi, Mauro
    Pedrizzetti, Gianni
    Salizzoni, Stefano
    De Ferrari, Gaetano Maria
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [44] Immobile Leaflets at Time of Bioprosthetic Valve Implantation: A Novel Risk Factor for Early Bioprosthetic Failure
    Naser, Jwan A.
    Crestanello, Juan A.
    Nkomo, Vuyisile T.
    Luis, Sushil A.
    Thaden, Jeremy J.
    Geske, Jeffrey B.
    Anderson, Jason H.
    Sinak, Lawrence J.
    Michelena, Hector, I
    Pislaru, Sorin, V
    Padang, Ratnasari
    HEART LUNG AND CIRCULATION, 2022, 31 (08) : 1166 - 1175
  • [45] Does Metabolic Syndrome Influence Bioprosthetic Mitral Valve Degeneration and Reoperation Rate?
    Meyer, Steven R.
    Suri, Rakesh M.
    Wright, R. Scott
    Dearani, Joseph A.
    Orszulak, Thomas A.
    Daly, Richard C.
    Burkhart, Harold M.
    Park, Soon J.
    Schaff, Hartzell V.
    JOURNAL OF CARDIAC SURGERY, 2012, 27 (02) : 146 - 151
  • [46] Analysis of Bioprosthetic Aortic Valve Thrombosis-Implications and Management Strategies
    Nunez-Gil, Ivan J.
    Alkhouli, Mohamad
    Centola, Marcos
    Feltes, Gisela
    Villablanca, Pedro
    Ramakrishna, Harish
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (10) : 2853 - 2860
  • [47] Long-Term Functional and Structural Durability of Bioprosthetic Valves Placed in the Aortic Valve Position via Percutaneous Rout in Israel
    Orvin, Katia
    Ben Zekry, Sagit
    Morelli, Olga
    Barabash, Israel M.
    Segev, Amit
    Danenberg, Haim
    Assali, Abid
    Guetta, Victor
    Assa, Hana Vaknin
    Zeniou, Vicki
    Lotan, Chaim
    Sagie, Alexander
    Gilon, Dan
    Feinberg, Micha S.
    Shapira, Yaron
    Ran, Kornowski
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (11) : 1748 - 1756
  • [48] Bioprosthetic Aortic Valve Thrombosis: Definitions, Clinical Impact, and Management: A State-of-the-Art Review
    Chitturi, Kalyan R.
    Aladin, Amer I.
    Braun, Ryan
    Al-Qaraghuli, Abdullah K.
    Banerjee, Avantika
    Reddy, Pavan
    Merdler, Ilan
    Chaturvedi, Abhishek
    Abusnina, Waiel
    Haberman, Dan
    Lupu, Lior
    Rodriguez-Weisson, Fernando J.
    Case, Brian C.
    Wermers, Jason P.
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    Rogers, Toby
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (07) : e014143
  • [49] Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves
    Bleiziffer, Sabine
    Simonato, Matheus
    Webb, John G.
    Rodes-Cabau, Josep
    Pibarot, Philippe
    Kornowski, Ran
    Windecker, Stephan
    Erlebach, Magdalena
    Duncan, Alison
    Seiffert, Moritz
    Unbehaun, Axel
    Frerker, Christian
    Conzelmann, Lars
    Wijeysundera, Harindra
    Kim, Won-Keun
    Montorfano, Matteo
    Latib, Azeem
    Tchetche, Didier
    Allali, Abdelhakim
    Abdel-Wahab, Mohamed
    Orvin, Katia
    Stortecky, Stefan
    Nissen, Henrik
    Holzamer, Andreas
    Urena, Marina
    Testa, Luca
    Agrifoglio, Marco
    Whisenant, Brian
    Sathananthan, Janarthanan
    Napodano, Massimo
    Landi, Antonio
    Fiorina, Claudia
    Zittermann, Armin
    Veulemans, Verena
    Sinning, Jan-Malte
    Saia, Francesco
    Brecker, Stephen
    Presbitero, Patrizia
    De Backer, Ole
    Sondergaard, Lars
    Bruschi, Giuseppe
    Franco, Luis Nombela
    Petronio, Anna Sonia
    Barbanti, Marco
    Cerillo, Alfredo
    Spargias, Konstantinos
    Schofer, Joachim
    Cohen, Mauricio
    Munoz-Garcia, Antonio
    Finkelstein, Ariel
    EUROPEAN HEART JOURNAL, 2020, 41 (29) : 2731 - 2742
  • [50] Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves
    Makkar, R. R.
    Fontana, G.
    Jilaihawi, H.
    Chakravarty, T.
    Kofoed, K. F.
    de Backer, O.
    Asch, F. M.
    Ruiz, C. E.
    Olsen, N. T.
    Trento, A.
    Friedman, J.
    Berman, D.
    Cheng, W.
    Kashif, M.
    Jelnin, V.
    Kliger, C. A.
    Guo, H.
    Pichard, A. D.
    Weissman, N. J.
    Kapadia, S.
    Manasse, E.
    Bhatt, D. L.
    Leon, M. B.
    Sondergaard, L.
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (21) : 2015 - 2024