Detection and Prediction of Bioprosthetic Aortic Valve Degeneration

被引:116
|
作者
Cartlidge, Timothy R. G. [1 ]
Doris, Mhairi K. [1 ]
Sellers, Stephanie L. [2 ]
Pawade, Tania A. [1 ]
White, Audrey C. [1 ]
Pessotto, Renzo [1 ]
Kwiecinski, Jacek [1 ]
Fletcher, Alison [3 ]
Alcaide, Carlos [1 ]
Lucatelli, Christophe [3 ]
Densem, Cameron [4 ]
Rudd, James H. F. [5 ]
van Beek, Edwin J. R. [3 ]
Tavares, Adriana [1 ]
Virmani, Renu [6 ]
Berman, Daniel [7 ]
Leipsic, Jonathon A. [2 ]
Newby, David E. [1 ]
Dweck, Marc R. [1 ]
机构
[1] Univ Edinburgh, British Heart Fdn, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Queens Med Res Inst, Edinburgh Imaging Facil, Edinburgh, Midlothian, Scotland
[3] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC, Canada
[4] Papworth Hosp NHS Fdn Trust, Dept Cardiol, Cambridge, England
[5] Univ Cambridge, Div Cardiovasc Med, Cambridge, England
[6] CVPath Inst, Gaithersburg, MD USA
[7] Cedars Sinai Heart Inst, Los Angeles, CA USA
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
aortic valve replacement; bioprosthetic valve degeneration; calcification; histology; positron emission tomography; SUBCLINICAL LEAFLET THROMBOSIS; PROSTHETIC HEART-VALVES; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; FLUORIDE UPTAKE; TRANSCATHETER; ECHOCARDIOGRAPHY; RECOMMENDATIONS; CALCIFICATION; REPLACEMENT;
D O I
10.1016/j.jacc.2018.12.056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences. OBJECTIVES The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction. METHODS Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up. RESULTS All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: -0.05 to 0.16] ms(-1)/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e. g., change in peak velocity, r <1/4> 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (targetto- background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction. CONCLUSIONS 18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276) (J Am Coll Cardiol 2019; 73: 1107-19) (c) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons. org/licenses/by/4.0/).
引用
收藏
页码:1107 / 1119
页数:13
相关论文
共 50 条
  • [21] Subclinical bioprosthetic aortic valve thrombosis: clinical and translational implications
    Yanagawa, Bobby
    Mazine, Amine
    Bhatt, Deepak L.
    Clavel, Marie-Annick
    Cote, Nancy
    Cheema, Asim N.
    Pibarot, Philippe
    Verma, Subodh
    CURRENT OPINION IN CARDIOLOGY, 2017, 32 (02) : 137 - 146
  • [22] Large Bioprosthetic Aortic Valve Thrombi on DOACs
    Bamford, Paul
    Rogers, James
    Bassin, Levi
    Kull, Anthony
    HEART LUNG AND CIRCULATION, 2019, 28 (10) : E139 - E142
  • [23] Risk Prediction in Aortic Valve Replacement: Incremental Value of the Preoperative Echocardiogram
    Tan, Timothy C.
    Flynn, Aidan W.
    Chen-Tournoux, Annabel
    Rudski, Lawrence G.
    Mehrotra, Praveen
    Nunes, Maria C.
    Rincon, Luis M.
    Shahian, David M.
    Picard, Michael H.
    Afilalo, Jonathan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2015, 4 (10):
  • [24] Performance of Echocardiographic Algorithms for Assessment of High Aortic Bioprosthetic Valve Gradients
    Bin Roslan, Aslannif
    Naser, Jwan A.
    Nkomo, Vuyisile T.
    Padang, Ratnasari
    Lin, Grace
    Pislaru, Cristina
    Greason, Kevin L.
    Pellikka, Patricia A.
    Eleid, Mackram F.
    Thaden, Jeremy J.
    Miller, Fletcher A.
    Pislaru, Sorin, V
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2022, 35 (07) : 682 - +
  • [25] Core Laboratory Versus Center-Reported Echocardiographic Assessment of the Native and Bioprosthetic Aortic Valve
    Velders, Bart J. J.
    Vriesendorp, Michiel D.
    Weissman, Neil J.
    Sabik, Joseph F.
    Reardon, Michael J.
    Dagenais, Francois
    Moront, Michael G.
    Rao, Vivek
    Fukuhara, Shinichi
    Guenzinger, Ralf
    van Leeuwen, Wouter J.
    Brown, W. Morris
    Groenwold, Rolf H. H.
    Klautz, Robert J. M.
    Asch, Federico M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2024, 41 (12):
  • [26] Early Hemodynamic Performance of the Trifecta Bioprosthetic Valve in Patients With Aortic Valve Disease - Initial Single-Center Experience in Japan -
    Maruyama, Masaki
    Daimon, Masao
    Kawata, Takayuki
    Kasai, Takatoshi
    Ichikawa, Ryoko
    Miyazaki, Sakiko
    Ohmura, Hirotoshi
    Yamamoto, Taira
    Amano, Atsushi
    Daida, Hiroyuki
    CIRCULATION JOURNAL, 2014, 78 (06) : 1372 - 1378
  • [27] Transcatheter Aortic Valve Implantation for Bioprosthetic Valve Failure: Placement of Aortic Transcatheter Valves 3 Aortic Valve-in-Valve Study
    Malaisrie, S. Chris
    Zajarias, Alan
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    Hahn, Rebecca T.
    Brown, David
    Wong, S. Chiu
    Oldemeyer, J. Bradley
    Shang, Kan
    Leipsic, Jonathon
    Blanke, Philipp
    Guerrero, Mayra
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2022, 6 (06):
  • [28] Subclinical Structural Valve Degeneration in Young Patients With Bioprosthetic Aortic Valves
    Percy, Edward D.
    Harloff, Morgan
    Hirji, Sameer
    Malarczyk, Alexandra
    Cherkasky, Olena
    Yazdchi, Farhang
    McGurk, Siobhan
    Shekar, Prem
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2021, 111 (05) : 1486 - 1493
  • [29] Thrombosis of Bioprosthetic Aortic Valve: Is the Entire Arsenal Deployed?
    Loardi, Claudia Maria
    Zanobini, Marco
    Vermes, Emmanuelle
    Mancini, Maria Elisabetta
    Bernard, Anne
    Tribouilloy, Christophe
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (07)
  • [30] Understanding the driving mechanisms of bioprosthetic valve degeneration
    Wachtell, Kristian
    HEART, 2024, 110 (04) : 223 - 224