Assessment of Fluid Status in Peritoneal Dialysis

被引:0
|
作者
Woodrow, Graham [1 ,2 ]
Ronco, Claudio [3 ]
机构
[1] St James Univ Hosp, Renal Unit, Leeds LS9 7TF, W Yorkshire, England
[2] Univ Leeds, Leeds, W Yorkshire, England
[3] San Bortolo Hosp, Dept Nephrol, Int Renal Res Inst, Vicenza, Italy
关键词
BODY-COMPOSITION; VOLUME; HYDRATION;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Fluid management is recognized as a basic component of management of patients on dialysis. Fluid overload is an important adverse factor in patient outcomes, and the negative effects of fluid depletion, including on residual renal function, are also increasingly being recognized. The complexities of fluid distribution in renal failure need to be understood to inform assessment of hydration. Clinical assessment of hydration is insensitive to abnormalities in hydration. BIA is the most promising technique for objective assessment of fluid status, but it is essential that the underlying principles and limitations are understood, and that results from BIA are utilized in conjunction with clinical assessment rather than in isolation. Copyright (C) 2012 S. Karger AG, Basel
引用
收藏
页码:164 / 168
页数:5
相关论文
共 50 条
  • [41] Cocaine Detection in Peritoneal Dialysis Fluid
    Gumber, Ramnika
    Shaw, Leslie M.
    Hogan, Jonathan J.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2017, 69 (01) : 161 - 161
  • [42] Peritoneal Angiogenesis in Response to Dialysis Fluid
    Rippe, Bengt
    PERITONEAL DIALYSIS - FROM BASIC CONCEPTS TO CLINICAL EXCELLENCE, 2009, 163 : 60 - 66
  • [43] FLUID TRANSPORT IN PERITONEAL-DIALYSIS
    LINDHOLM, B
    WERYNSKI, A
    BERGSTROM, J
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (06): : 352 - 358
  • [44] Fluid Transport and Homeostasis in Peritoneal Dialysis
    Teixido Planas, Josep
    PERITONEAL DIALYSIS - STATE-OF-THE-ART 2012, 2012, 178 : 169 - 173
  • [45] Fluid Overload in Peritoneal Dialysis Patients
    Kim, Yong-Lim
    Van Biesen, Wim
    SEMINARS IN NEPHROLOGY, 2017, 37 (01) : 43 - 53
  • [46] HAZARD OF PERITONEAL DIALYSIS - CONTAMINATED FLUID
    STEWART, WK
    ANDERSON, DC
    WILSON, MI
    BRITISH MEDICAL JOURNAL, 1967, 1 (5540): : 606 - &
  • [47] Is there such a thing as biocompatible peritoneal dialysis fluid?
    Claus Peter Schmitt
    Christoph Aufricht
    Pediatric Nephrology, 2017, 32 : 1835 - 1843
  • [48] Icodextrin: an alternative peritoneal dialysis fluid
    Chhabra, Darshika
    Nash, Kevin
    EXPERT OPINION ON DRUG METABOLISM & TOXICOLOGY, 2008, 4 (11) : 1455 - 1464
  • [49] ASSESSMENT OF BODY FLUID VOLUME USING THE BIOIMPEDANCE METHOD IN PERITONEAL DIALYSIS PATIENTS
    Moriishi, Misaki
    Kawanishi, Hideki
    Shintaku, Sadanori
    Tsuchiya, Shinichiro
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1520 - 1520
  • [50] The status of continuous ambulatory peritoneal dialysis
    Nolph, K.D.
    International Journal of Artificial Organs, 1980, 3 (04): : 235 - 236