A preliminary evaluation of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias

被引:11
|
作者
Wan, Jun-Hui [1 ]
Tian, Pei-Ling [2 ]
Yin, Hao [3 ]
Han, Yun [3 ]
Wei, Xiang-Cai [2 ]
Pan, Tao [3 ]
机构
[1] Prenatal Diag Ctr, Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
[2] Family Planning Res Inst Guangdong, Guangzhou 510515, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Higher Educ Inst, Key Lab Optoelect Informat & Sensing Technol, Guangzhou 510632, Guangdong, Peoples R China
关键词
ATR-FTIR; Hemoglobin; Mean corpuscular volume; Mean corpuscular hemoglobin; Thalassemia; BETA-THALASSEMIA; IN-SITU; DIAGNOSIS; ALPHA; IDENTIFICATION; TOOL;
D O I
10.1016/j.clinbiochem.2012.10.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The effectiveness of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias was evaluated. Design and methods: The correlations of hemoglobin, mean corpuscular volume and mean corpuscular hemoglobin between routine method and attenuated total reflection Fourier transform infrared spectroscopy were analyzed using linear regression analysis. Appropriate cut-off values of predicted mean corpuscular volume and predicted mean corpuscular hemoglobin in screening of thalassemias were derived from the receiver operator characteristic curve conducted on 103 subjects. Results: Obvious positive correlations of hemoglobin (beta = 0.876, R-2=0.791, P<0.001), mean corpuscular volume (beta = 0.658, R-2=0.516, P<0.001) and mean corpuscular hemoglobin (beta = 0.674, R-2=0.583, P<0.001) were observed between routine method and attenuated total reflection Fourier transform infrared spectroscopy. Based on the receiver operator characteristic curve analysis, the best cut off value of predicted mean corpuscular volume for the phenotype-positive subjects was found to be 79.9 fl with & sensitivity of 100.0% and-a specificity of 97.8%, and the proposed cut off value of predicted mean corpuscular hemoglobin was 27.3 pg with a sensitivity of 100.0% and a specificity of 96.8%. The area under curve was 0.996 for predicted mean corpuscular volume and 0.992 for predicted mean corpuscular hemoglobin, respectively. Conclusions: The established method could be an additional potentially promising tool for the preliminary screening of thalassemias in population prevention and control program. The main advantage of this method is no unwanted chemical regents compared with conventional method. Strategy for the development of this method could be of use for the other important parameters of thalassemias. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [21] Fast Determination of Induction Period of Motor Gasoline Using Fourier Transform Attenuated Total Reflection Infrared Spectroscopy
    Liu Ya-fei
    Yuan Hong-fu
    Song Chun-feng
    Xie Jin-chun
    Li Xiao-yu
    Yan De-lin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (11) : 2929 - 2933
  • [22] Identification of fatal hypothermia via attenuated total reflection Fourier transform infrared spectroscopy of rabbit vitreous humour
    Zhang, Zhong
    Lin, Hancheng
    Li, Zhengdong
    Luo, Yiwen
    Wang, Lei
    Chen, Liqin
    Huang, Ping
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2021, 53 (01) : 27 - 39
  • [23] Discerning Some Tylenol Brands Using Attenuated Total Reflection Fourier Transform Infrared Data and Multivariate Analysis Techniques
    Msimanga, Huggins Z.
    Ollis, Robert J., Jr.
    APPLIED SPECTROSCOPY, 2010, 64 (06) : 657 - 668
  • [24] Differentiation of Cosmetic Foundation Creams Using Attenuated Total Reflection Fourier-Transform Infrared Spectroscopy: A Rapid and NonDestructive Approach in Trace Evidence Analysis
    Sharma, Sweety
    Chophi, Rito
    Kaur, Harkamalpreet
    Singh, Rajinder
    JOURNAL OF FORENSIC SCIENCES, 2020, 65 (03) : 751 - 761
  • [25] Attenuated Total Reflection-Fourier Transform Infrared Spectroscopic Study of Dried Shark Fin Products
    Han Wan-qing
    Luo Hai-ying
    Xian Yan-ping
    Luo Dong-hui
    Mu Tong-na
    Guo Xin-dong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (02) : 379 - 383
  • [26] Detection of lung cancer tissue by attenuated total reflection-Fourier transform infrared spectroscopy-a pilot study of 60 samples
    Sun, Xiaoliang
    Xu, Yizhuang
    Wu, Jinguang
    Zhang, Yuanfu
    Sun, Kelin
    JOURNAL OF SURGICAL RESEARCH, 2013, 179 (01) : 33 - 38
  • [27] Attenuated Total Reflection Fourier Transform Infrared Spectroscopy for Forensic Screening of Long-Term Alcohol Consumption from Human Nails
    Mitu, Bilkis
    Cerda, Migdalia
    Hrib, Radovan
    Trojan, Vaiclav
    Halaimkovai, Lenka
    ACS OMEGA, 2023, 8 (24): : 22203 - 22210
  • [28] Attenuated total reflection-Fourier transform infrared spectroscopy: a universal analytical technique with promising applications in forensic analyses
    Alkhuder, Khaled
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2022, 136 (06) : 1717 - 1736
  • [29] Attenuated total reflection-Fourier transform infrared spectroscopy: a universal analytical technique with promising applications in forensic analyses
    Khaled Alkhuder
    International Journal of Legal Medicine, 2022, 136 : 1717 - 1736
  • [30] Attenuated total reflection-Fourier transform infrared spectroscopy: a tool to characterize antimicrobial cyclic peptide–membrane interactions
    Bárbara Claro
    Erik Goormaghtigh
    Margarida Bastos
    European Biophysics Journal, 2021, 50 : 629 - 639