A preliminary evaluation of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias

被引:11
作者
Wan, Jun-Hui [1 ]
Tian, Pei-Ling [2 ]
Yin, Hao [3 ]
Han, Yun [3 ]
Wei, Xiang-Cai [2 ]
Pan, Tao [3 ]
机构
[1] Prenatal Diag Ctr, Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
[2] Family Planning Res Inst Guangdong, Guangzhou 510515, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Higher Educ Inst, Key Lab Optoelect Informat & Sensing Technol, Guangzhou 510632, Guangdong, Peoples R China
关键词
ATR-FTIR; Hemoglobin; Mean corpuscular volume; Mean corpuscular hemoglobin; Thalassemia; BETA-THALASSEMIA; IN-SITU; DIAGNOSIS; ALPHA; IDENTIFICATION; TOOL;
D O I
10.1016/j.clinbiochem.2012.10.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The effectiveness of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias was evaluated. Design and methods: The correlations of hemoglobin, mean corpuscular volume and mean corpuscular hemoglobin between routine method and attenuated total reflection Fourier transform infrared spectroscopy were analyzed using linear regression analysis. Appropriate cut-off values of predicted mean corpuscular volume and predicted mean corpuscular hemoglobin in screening of thalassemias were derived from the receiver operator characteristic curve conducted on 103 subjects. Results: Obvious positive correlations of hemoglobin (beta = 0.876, R-2=0.791, P<0.001), mean corpuscular volume (beta = 0.658, R-2=0.516, P<0.001) and mean corpuscular hemoglobin (beta = 0.674, R-2=0.583, P<0.001) were observed between routine method and attenuated total reflection Fourier transform infrared spectroscopy. Based on the receiver operator characteristic curve analysis, the best cut off value of predicted mean corpuscular volume for the phenotype-positive subjects was found to be 79.9 fl with & sensitivity of 100.0% and-a specificity of 97.8%, and the proposed cut off value of predicted mean corpuscular hemoglobin was 27.3 pg with a sensitivity of 100.0% and a specificity of 96.8%. The area under curve was 0.996 for predicted mean corpuscular volume and 0.992 for predicted mean corpuscular hemoglobin, respectively. Conclusions: The established method could be an additional potentially promising tool for the preliminary screening of thalassemias in population prevention and control program. The main advantage of this method is no unwanted chemical regents compared with conventional method. Strategy for the development of this method could be of use for the other important parameters of thalassemias. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 26 条
[1]   Prenatal diagnosis in beta-thalassemia: An Indian experience [J].
Agarwal, S ;
Gupta, A ;
Gupta, UR ;
Sarwai, S ;
Phadke, S ;
Agarwal, SS .
FETAL DIAGNOSIS AND THERAPY, 2003, 18 (05) :328-332
[2]   Bone Marrow Mesenchymal Stem Cells in Patients with Beta Thalassemia Major: Molecular Analysis with Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy Study as a Novel Method [J].
Aksoy, Ceren ;
Guliyev, Ali ;
Kilic, Emine ;
Uckan, Duygu ;
Severcan, Feride .
STEM CELLS AND DEVELOPMENT, 2012, 21 (11) :2000-2011
[3]   USE OF INTERNAL REFLECTANCE INFRARED-SPECTROSCOPY FOR THE IN-SITU STUDY OF SUPPORTED LIPID MONOLAYERS [J].
AXELSEN, PH ;
BRADDOCK, WD ;
BROCKMAN, HL ;
JONES, CM ;
DLUHY, RA ;
KAUFMAN, BK ;
PUGA, FJ .
APPLIED SPECTROSCOPY, 1995, 49 (04) :526-531
[4]   Prenatal diagnosis and screening of the haemoglobinopathies [J].
Cao, A ;
Galanello, R ;
Rosatelli, MC .
BAILLIERES CLINICAL HAEMATOLOGY, 1998, 11 (01) :215-238
[5]   Improving real-time measurement of H/D exchange using a FTIR biospectroscopic probe [J].
Carmona, Pedro ;
Rodriguez-Casado, Arantxa ;
Molina, Marina .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (04) :1289-1295
[6]  
Chong SS, 2000, BLOOD, V95, P360
[7]   Infrared spectroscopic studies of nanoscale iron oxide deposits isolated from human thalassemic tissues [J].
Chua-anusorn, W ;
Webb, J .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :303-309
[8]   Validation of dHPLC for molecular diagnosis of β-thalassemia in Southern Italy [J].
Colosimo, A ;
Guida, V ;
Scolari, A ;
De Luca, A ;
Palka, G ;
Rigoli, L ;
Meo, A ;
Salpietro, DC ;
Dallapiccola, B .
GENETIC TESTING, 2003, 7 (03) :269-275
[9]   Infrared ATR spectroscopy of substrates in aqueous solution using cryoenrichment and its application in enzyme-activity assays [J].
Fujii, T ;
Miyahara, Y .
APPLIED SPECTROSCOPY, 1998, 52 (01) :128-133
[10]   Haemoglobinopathy analyses in the Netherlands:: a report of an in vitro globin chain biosynthesis survey using a rapid, modified method [J].
Giordano, PC ;
Van Delft, P ;
Batelaan, D ;
Harteveld, CL ;
Bernini, LF .
CLINICAL AND LABORATORY HAEMATOLOGY, 1999, 21 (04) :247-255