Bond strength between corroded steel reinforcement and recycled aggregate concrete

被引:61
作者
Alhawat, Musab [1 ]
Ashour, Ashraf [1 ]
机构
[1] Univ Bradford, Sch Engn & Informat, Bradford BD7 1DP, W Yorkshire, England
关键词
Recycled coarse aggregat; Corrosion; Bond strength; Embadment length; Steel bar size; Pull-out test; MECHANICAL-PROPERTIES; COMPRESSIVE STRENGTH; COARSE AGGREGATE; CORROSION; BEHAVIOR; BARS; CONSTRUCTION; WASTE;
D O I
10.1016/j.istruc.2019.02.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the bond performance of recycled coarse aggregate (RCA) concrete with un-corroded/ corroded reinforcing steel bars, with the main parameters being RCA content, corrosion level, bar diameter and embedment length. For this purpose, 60 pull-out specimens containing different percentages of RCA (i.e. 0%, 25%, 50% and 100%) and steel bars of two diameters (12 and 20 mm) and different embedment lengths were tested. In order to establish various levels of corrosion, specimens were exposed to an electrochemical corrosion for 2, 5, 10 and 15 days. The bond strength between RAC concrete and un-corroded/corroded steel are compared to current codes and equations proposed by other researchers. Experimental results showed that larger corrosion rate of steel bars was observed with the increase of the replacement level of RCA due to its high porosity and water absorption. The use of RCA had a slight influence on bond strength for un-corroded specimens compared to that obtained from conventional concrete. Furthermore, the bond strength of RCA concrete was strongly affected by corrosion products; bond strength slightly enhanced for up to about 2% corrosion rate, and then significantly decreased as the corrosion time further increased, similar to that of conventional concrete. However, the rate of bond degradation between RCA concrete and corroded steel bars was much faster than that observed in corroded conventional concrete.
引用
收藏
页码:369 / 385
页数:17
相关论文
共 69 条
[61]  
Wassouf M, 2015, BOND DUCTILITY CONCR
[62]   Bond behaviour between recycled aggregate concrete and steel rebars [J].
Xiao, Jianzhuang ;
Falkner, H. .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (02) :395-401
[63]   An overview of study on recycled aggregate concrete in China (1996-2011) [J].
Xiao, Jianzhuang ;
Li, Wengui ;
Fan, Yuhui ;
Huang, Xiao .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 31 :364-383
[64]  
Yang K-H., 2008, INFLUENCE TYPE REPLA
[65]  
Yuan YS, 2007, ACI STRUCT J, V104, P344
[66]   Bond behaviour of normal/recycled concrete and corroded steel bars [J].
Zhao, Yuxi ;
Lin, Hongwei ;
Wu, Kang ;
Jin, Weiliang .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 :348-359
[67]   Influence of fine recycled concrete aggregates on the properties of mortars [J].
Zhao, Zengfeng ;
Remond, Sebastien ;
Damidot, Denis ;
Xu, Weiya .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 81 :179-186
[68]  
Zuo J, 1998, BOND STRENGTH HIGH R
[69]  
Zuo J., 2000, Splice strength of conventional and high relative rib area bars in normal and high-strength concrete