COMPARISON OF MAGNETIC TRACKING AND OPTICAL TRACKING BY SIMULTANEOUS USE OF TWO INDEPENDENT FRAMELESS STEREOTACTIC SYSTEMS

被引:45
作者
Mascott, Christopher R. [1 ]
机构
[1] Beaumont Hosp, Dept Neurosurg, Royal Coll Surg Ireland, Dublin 9, Ireland
关键词
Application accuracy; Electromagnetic referencing; Frameless; Image guidance; Optical referencing;
D O I
10.1227/01.NEU.0000176411.55324.1E
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The goal of this study was to compare the calculated accuracy and the true surgical accuracy of a magnetic and an optical tracking system at surgical registration and during surgery. METHODS: Two Food and Drug Administration-approved, commercially available frameless stereotactic systems were used simultaneously in 70 surgical cases. The Compass Cygnus-PFS system (Compass International, Rochester MN) uses magnetic field referencing and tracking. The StealthStation (Medtronic SNT, Louisville, CO) uses optical referencing and tracking. Registration was performed for each of the systems using adhesive fiducial markers, cranial-implanted markers, anatomic landmarks, or a combination thereof. Preoperative imaging consisted of volumetric computed tomography, magnetic resonance imaging, or both. Calculated accuracy was given by each of the systems as the root mean square after registration. Surgical accuracy was assessed by comparing the anatomic accuracy of each system with a number of recognizable intraoperative anatomic landmarks RESULTS: Calculated accuracy (root mean square) was 1.4 +/- 0.6 mm using the magnetic system and 1.4 +/- 0.8 mm using the optical tracking system. In the 42 patients with implanted cranial fiducials, the calculated accuracies were 1.0 +/- 0.5 mm (magnetic) and 0.9 +/- 0.4 mm (optical). True surgical accuracy was considered good (3 mm or less) in both systems in 60 of 70 patients. In two patients, neither system was accurate. In eight patients, one of the two systems was considered inaccurate. Of these, the magnetic system was considered inaccurate three times and the optical system five times. CONCLUSION: Magnetic referencing and tracking was found to be comparable with optical tracking both with regard to calculated and true surgical accuracy. Interference from metal objects in the magnetic field was seen rarely.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 27 条
[1]   INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
JOURNAL OF NEUROSURGERY, 1993, 78 (03) :510-514
[2]   Comparison of frameless stereotactic systems: Accuracy, precision, and applications [J].
Benardete, EA ;
Leonard, MA ;
Weiner, HL .
NEUROSURGERY, 2001, 49 (06) :1409-1415
[3]   Postimaging brain distortion: magnitude, correlates, and impact on neuronavigation [J].
Dorward, NL ;
Alberti, O ;
Velani, B ;
Gerritsen, FA ;
Harkness, WFJ ;
Kitchen, ND ;
Thomas, DGT .
JOURNAL OF NEUROSURGERY, 1998, 88 (04) :656-662
[4]  
Doshi PK, 1995, ADV STER F, V11, P49
[5]   Clinical use of the optical digitizer for intracranial neuronavigation [J].
Germane, IM ;
Villalobos, H ;
Silvers, A ;
Post, KD .
NEUROSURGERY, 1999, 45 (02) :261-269
[6]   Stereotactic biopsies guided by an optical navigation system:: Technique and clinical experience [J].
Grunert, P ;
Espinosa, J ;
Busert, C ;
Günthner, M ;
Filippi, R ;
Farag, S ;
Hopf, N .
MINIMALLY INVASIVE NEUROSURGERY, 2002, 45 (01) :11-15
[7]   BrainLab VectorVision neuronavigation system: Technology and clinical experiences in 131 cases [J].
Gumprecht, HK ;
Widenka, DC ;
Lumenta, CB .
NEUROSURGERY, 1999, 44 (01) :97-104
[8]   Measurement of intraoperative brain surface deformation under a craniotomy [J].
Hill, DLG ;
Maurer, CR ;
Maciunas, RJ ;
Barwise, JA ;
Fitzpatrick, JM ;
Wang, MY .
NEUROSURGERY, 1998, 43 (03) :514-526
[9]   A FRAMELESS, ARMLESS NAVIGATIONAL SYSTEM FOR COMPUTER-ASSISTED NEUROSURGERY [J].
KATO, A ;
YOSHIMINE, T ;
HAYAKAWA, T ;
TOMITA, Y ;
IKEDA, T ;
MITOMO, M ;
HARADA, K ;
MOGAMI, H .
JOURNAL OF NEUROSURGERY, 1991, 74 (05) :845-849
[10]  
Kleinpeter G, 2003, MINIM INVAS NEUROSUR, V46, P257