Total internal reflection photoacoustic spectroscopy for the detection of β-hematin

被引:10
作者
Goldschmidt, Benjamin S. [1 ]
Sudduth, Amanda S. M. [1 ]
Samson, Edward B. [1 ]
Whiteside, Paul J. D. [1 ]
Bhattacharyya, Kiran D. [1 ]
Viator, John A. [1 ]
机构
[1] Univ Missouri, Christopher S Bond Life Sci Ctr, Columbia, MO 65211 USA
关键词
photoacoustic spectroscopy; refractive index; absorption; medicine; engineering; BIOSENSORS; SPECTROMETRY; INTERFACE; TIME; PATH;
D O I
10.1117/1.JBO.17.6.061212
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Evanescent field sensing methods are currently used to detect many different types of disease markers and biologically important chemicals such as the HER2 breast cancer receptor. Hinoue et al. used Total Internal Reflection Photoacoustic Spectroscopy (TIRPAS) as a method of using the evanescent field to detect an optically opaque dye at a sample interface. Although their methods were successful at detecting dyes, the results at that time did not show a very practical spectroscopic technique, which was due to the less than typical sensitivity of TIRPAS as a spectroscopy modality given the low power (similar to 1 to 2 W) lasers being used. Contrarily, we have used an Nd:YAG laser with a five nanosecond pulse that gives peak power of 1 MW coupled with the TIRPAS system to increase the sensitivity of this technique for biological material sensing. All efforts were focused on the eventual detection of the optically absorbing material, hemozoin, which is created as a byproduct of a malarial infection in blood. We used an optically analogous material, beta-hematin, to determine the potential for detection in the TIRPAS system. In addition, four properties which control the sensitivity were investigated to increase understanding about the sensor's function as a biosensing method. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.6.061212]
引用
收藏
页数:8
相关论文
共 23 条
[1]   Acoustic-based measurements of material absorption coefficients: Relationship between laser pulse duration and stress confinement time [J].
Choi, B ;
Jansen, ED ;
Welch, AJ .
JOURNAL OF APPLIED PHYSICS, 2003, 94 (12) :7826-7831
[2]   LONG PATH FIBER-OPTIC SENSOR FOR EVANESCENT FIELD ABSORBANCE MEASUREMENTS [J].
DEGRANDPRE, MD ;
BURGESS, LW .
ANALYTICAL CHEMISTRY, 1988, 60 (23) :2582-2586
[3]   The mechanism of β-hematin formation in acetate solution, parallels between hemozoin formation and biomineralization processes [J].
Egan, TJ ;
Mavuso, WW ;
Ncokazi, KK .
BIOCHEMISTRY, 2001, 40 (01) :204-213
[4]  
Florens L., 2002, ASMS 50th Anniversary Volume, P59, DOI DOI 10.1002/CFG.207
[5]   Detection of HER2 breast cancer biomarker using the opto-fluidic ring resonator biosensor [J].
Gohring, John T. ;
Dale, Paul S. ;
Fan, Xudong .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :226-230
[6]  
Harrick N.J., 1987, INTERNAL REFLECTION
[7]   MEASUREMENT OF CONCENTRATION PROFILE OF DYE AT GLASS-SOLUTION INTERFACE BY PHOTOACOUSTIC SPECTROMETRY COUPLED WITH TOTAL INTERNAL-REFLECTION TECHNIQUE [J].
HINOUE, T ;
KAWABE, M ;
YOKOYAMA, Y .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1987, 60 (10) :3811-3813
[8]  
HINOUE T, 1984, BUNSEKI KAGAKU, V33, pE459
[9]   PHOTO-ACOUSTIC OBSERVATION OF SOLID-LIQUID INTERFACE BY MEANS OF TOTAL INTERNAL-REFLECTION TECHNIQUE [J].
HINOUE, T ;
SHIMAHARA, Y ;
YOKOYAMA, Y .
CHEMISTRY LETTERS, 1983, (02) :225-228
[10]  
Hinoue T, 1986, ANAL SCI, V2, P401