Ex vivo determination of glucose permeability and optical attenuation coefficient in normal and adenomatous human colon tissues using spectral domain optical coherence tomography

被引:20
|
作者
Zhao, Qingliang [1 ]
Zhou, Chuanqing [1 ]
Wei, Huajiang [2 ,3 ]
He, Yonghong [4 ]
Chai, Xinyu [1 ]
Ren, Qiushi [5 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200240, Peoples R China
[2] S China Normal Univ, MOE Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
[3] S China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
[4] Tsinghua Univ, Lab Opt Imaging & Sensing, Grad Sch Shenzhen, Shenzhen 518055, Peoples R China
[5] Peking Univ, Coll Engn, Dept Biomed Engn, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
permeability coefficient; glucose; attenuation coefficient; colon adenocarcinoma; spectral domain optical coherence tomography; SCATTERING MEDIA; DIFFUSION; QUANTIFICATION; COLLAGEN; AGENTS;
D O I
10.1117/1.JBO.17.10.105004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent reports have suggested that spectral domain optical coherence tomography (SD-OCT) is a useful tool for quantifying the permeability of hyperosmotic agents in various tissues. We report our preliminary results on quantification of glucose diffusion and assessment of the optical attenuation change due to the diffusion of glucose in normal and adenomatous human colon tissues in vitro by using a SD-OCT and then calculated the permeability coefficients (PC) and optical attenuation coefficients (AC). The PC of a 30% aqueous solution of glucose was 3.37 +/- 0.23 x 10(-6) cm/s in normal tissue and 5.65 +/- 0.16 x 10(-6) cm/s in cancerous colon tissue. Optical AC in a normal colon ranged from 3.48 +/- 0.37 to 2.68 +/- 0.82 mm(-1) and was significantly lower than those seen in the cancerous tissue (8.48 +/- 0.95 to 3.16 +/- 0.69 mm(-1), p < 0.05). The results suggest that quantitative measurements of using PC and AC from OCT images could be a potentially powerful method for colon cancer detection. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.10.105004]
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Blood glucose monitoring in human subjects using optical coherence tomography
    Jitendra Solanki
    Pratima Sen
    Joseph Thomas Andrews
    Kamal Kishore Thareja
    Journal of Optics, 2012, 41 (3) : 127 - 133
  • [32] Determination of optical properties of oxidative bleaching human dental tissue samples using optical coherence tomography
    Ni, Y. R.
    Guo, Z. Y.
    Shu, S. Y.
    Zeng, C. C.
    Zhong, H. Q.
    Chen, B. L.
    Liu, Z. M.
    Bao, Y.
    LASER PHYSICS, 2012, 22 (01) : 294 - 299
  • [33] Ex-vivo analysis of demineralisation on irradiated teeth using optical coherence tomography
    Saberi, Fatin Najwa Mohamad
    Liew, Yih Miin
    Sukumaran, Prema
    Ung, Ngie Min
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 43
  • [34] Peripapillary choroidal thickness assessed by spectral-domain optical coherence tomography in normal Japanese
    Shibata, Hitomi
    Sawada, Yu
    Ishikawa, Makoto
    Yoshitomi, Takeshi
    Iwase, Takeshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (05) : 666 - 671
  • [35] Evaluation of Moisture-Related Attenuation Coefficient and Water Diffusion Velocity in Human Skin Using Optical Coherence Tomography
    Lee, Cheng-Kuang
    Tsai, Meng-Tsan
    Chang, Feng-Yu
    Yang, Chih-Hsun
    Shen, Su-Chin
    Yuan, Ouyang
    Yang, Chih-He
    SENSORS, 2013, 13 (04): : 4041 - 4050
  • [36] Peripapillary choroidal thickness assessed by spectral-domain optical coherence tomography in normal Japanese
    Hitomi Shibata
    Yu Sawada
    Makoto Ishikawa
    Takeshi Yoshitomi
    Takeshi Iwase
    Japanese Journal of Ophthalmology, 2021, 65 : 666 - 671
  • [37] Myocardial imaging using ultrahigh-resolution spectral domain optical coherence tomography
    Yao, Xinwen
    Gan, Yu
    Marboe, Charles C.
    Hendon, Christine P.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [38] Longitudinal Analysis of Progression in Glaucoma Using Spectral-Domain Optical Coherence Tomography
    Wessel, Julia M.
    Horn, Folkert K.
    Tornow, Ralf P.
    Schmid, Matthias
    Mardin, Christian Y.
    Kruse, Friedrich E.
    Juenemann, Anselm G.
    Laemmer, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3613 - 3620
  • [39] Detection of mild papilloedema in posterior uveitis using spectral domain optical coherence tomography
    Philiponnet, A.
    Vardanian, C.
    Malcles, A.
    Pochat, C.
    Sallit, R.
    Kodjikian, L.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 401 - 405
  • [40] A Hierarchical Cluster Analysis of Normal-Tension Glaucoma Using Spectral-Domain Optical Coherence Tomography Parameters
    Bae, Hyoung Won
    Ji, Yongwoo
    Lee, Hye Sun
    Lee, Naeun
    Hong, Samin
    Seong, Gong Je
    Sung, Kyung Rim
    Kim, Chan Yun
    JOURNAL OF GLAUCOMA, 2015, 24 (04) : 328 - 333