Body composition assessment in adults with cystic fibrosis: comparison of dual-energy X-ray absorptiometry with skinfolds and bioelectrical impedance analysis

被引:36
|
作者
King, S
Wilson, J
Kotsimbos, T
Bailey, M
Nyulasi, I
机构
[1] Monash Univ, Alfred Hosp, Dept Med, Melbourne, Vic 3004, Australia
[2] Alfred Hosp, Dept Nutr, Melbourne, Vic, Australia
[3] Alfred Hosp, Dept Allergy Immunol & Resp Med, Melbourne, Vic, Australia
[4] Monash Univ, Dept Epidemiol & Prevent Med, Melbourne, Vic 3004, Australia
[5] Monash Univ, Med Ctr, Dept Med, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
cystic fibrosis; nutritional assessment; body composition; dual-energy X-ray absorptiometry; bioelectrical impedance analysis;
D O I
10.1016/j.nut.2005.04.005
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: We compared body composition measurement in adults with cystic fibrosis (CF) by using non-invasive methods (skinfold thicknesses and bioelectrical impedance analysis [BIA]) with dual-energy X-ray absorptiometry (DXA). Methods: Seventy-six adults with CF (mean age 29.9 +/- 7.9 y, mean body mass index 21.5 +/- 2.5 kg/m(2)) were studied. Body composition was measured to calculate fat-free mass (FFM) using DXA, the sum of four skinfold thicknesses, and BIA (predictive equations of Lukaski and of Segal). Results: Mean FFM values +/- standard deviation measured using DXA were 54.8 +/- 7.3 kg in men and 41.2 +/- 3.9 kg in women. Mean FFM values measured using BIA/Lukaski were 51.5 +/- 7.8 kg in men and 40.4 +/- 4.9 kg in women (P < 0.0005 for men, not significant for women for comparison with DXA). Mean FFM values measured using BIA/Segal were 54.2 +/- 7.5 kg for men and 44.1 +/- 5.9 kg for women (not significant for men, P < 0.0005 for women for comparison with DXA). Mean FFM values measured using skinfolds were significantly higher than those for FFM with DXA (57.2 +/- 7.2 kg in men, 43.3 +/- 4.3 kg in women, P < 0.0005 for comparison with DXA). The 95% limits of agreement with FFM using DXA were, for men and women, respectively, -8.3 to 1.7 kg and -6.4 to 4.8 kg for BIA/Lukaski, -4.8 to 3.6 kg and -3.1 to 8.9 kg for BIA/Segal, and -2.8 to 7.3 kg and -1.5 to 5.7 kg for skinfolds. Conclusion: This study suggests that skinfold thickness measurements and BIA will incorrectly estimate FFM in many adults with CF compared with DXA measurements of FFM. These methods have limited application in the assessment of body composition in individual adult patients with CF. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [41] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [42] New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry
    Kyle, UG
    Pichard, C
    Rochat, T
    Slosman, DO
    Fitting, JW
    Thiebaud, D
    EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (04) : 960 - 966
  • [43] A Comparative Study of High-Frequency Bioelectrical Impedance Analysis and Dual-Energy X-ray Absorptiometry for Estimating Body Composition
    Yi, Youngseok
    Baek, Ji Yeon
    Lee, Eunju
    Jung, Hee-Won
    Jang, Il-Young
    LIFE-BASEL, 2022, 12 (07):
  • [44] Changes in body composition during weight loss in obese subjects in the NUGENOB study: Comparison of bioelectrical impedance vs. dual-energy X-ray absorptiometry
    Verdich, C.
    Barbe, P.
    Petersen, M.
    Grau, K.
    Ward, L.
    Macdonald, I.
    Sorensen, T. I. A.
    Oppert, J. -M.
    DIABETES & METABOLISM, 2011, 37 (03) : 222 - 229
  • [45] Evaluation of body composition using dual-energy x-ray absorptiometry, skinfold thickness and bioelectrical impedance analysis in Japanese female college students
    Kitano, T
    Kitano, N
    Inomoto, T
    Futatsuka, M
    JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 2001, 47 (02) : 122 - 125
  • [46] Different calculations of fat-free mass by bioelectrical impedance analysis: Comparison with Dual-Energy X-Ray Absorptiometry
    Varlet-Marie, E.
    Grubka, E.
    Karafiat, M.
    Fedou, C.
    de Mauverger, E. Raynaud
    Brun, J. -F.
    SCIENCE & SPORTS, 2009, 24 (3-4) : 202 - 206
  • [47] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Maura Helba
    Larry A. Binkovitz
    Pediatric Radiology, 2009, 39 : 647 - 656
  • [48] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Helba, Maura
    Binkovitz, Larry A.
    PEDIATRIC RADIOLOGY, 2009, 39 (07) : 647 - 656
  • [49] MEASUREMENT OF BODY-FAT IN ELDERLY SUBJECTS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY, BIOELECTRICAL IMPEDANCE, AND ANTHROPOMETRY
    SVENDSEN, OL
    HAARBO, J
    HEITMANN, BL
    GOTFREDSEN, A
    CHRISTIANSEN, C
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (05): : 1117 - 1123
  • [50] DETERMINATION OF BODY-COMPOSITION - A COMPARISON OF DUAL-ENERGY X-RAY ABSORPTIOMETRY AND HYDRODENSITOMETRY
    JOHANSSON, AG
    FORSLUND, A
    SJODIN, A
    MALLMIN, H
    HAMBRAEUS, L
    LJUNGHALL, S
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (03): : 323 - 326