Microsecond-scale X-ray imaging with Controlled-Drift Detectors

被引:0
|
作者
Castoldi, A
Galimberti, A
Guazzoni, C
Rehak, P
Strüder, L
机构
[1] Politecn Milan, Dip Ingn Nucl CeSNEF, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[3] Politecn Milan, Dipartimento Elettron & Informat, I-20133 Milan, Italy
[4] Brookhaven Natl Lab, Upton, NY 11973 USA
[5] MPI Halbleiterlabor, D-81739 Munich, Germany
关键词
D O I
10.1016/j.nuclphysbps.2004.06.005
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The Controlled-Drift Detector is a fully-depleted silicon detector that allows 2-D position sensing and energy spectroscopy of X-rays in the range 0.5-20keV with excellent time resolution (few tens of mu s) and limited readout channels. In this paper we review the Controlled-Drift Detector operating principle and we present the X-ray imaging and spectroscopic capabilities of Controlled Drift Detectors in microsecond-scale experiments and the more relevant applications fields.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 50 条
  • [41] X-ray polarimeters based on silicon PIN diodes and drift detectors
    Kotthaus, R
    Buschhorn, G
    Pugachev, D
    Shooshtari, H
    They, J
    ULTRAVIOLET AND X-RAY DETECTION, SPECTROSCOPY, AND POLARIMETRY III, 1999, 3764 : 49 - 60
  • [42] Fast X-Ray Spectroscopy Using Si-Drift Detectors
    Hansen, Karsten
    Reckleben, Christian
    Diehl, Inge
    Klaer, Helmut
    Welter, Edmund
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1666 - 1670
  • [43] Silicon drift detectors with on-chip electronics for X-ray spectroscopy
    Politecnico di Milano, Milano, Italy
    J X Ray Sci Technol, 2 (117-129):
  • [44] A comparison of x-ray detectors for mouse CT imaging
    Goertzen, AL
    Nagarkar, V
    Street, RA
    Paulus, MJ
    Boone, JM
    Cherry, SR
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5251 - 5265
  • [45] Diamond Detectors for UV and X-Ray Source Imaging
    Girolami, Marco
    Allegrini, Paolo
    Conte, Gennaro
    Trucchi, Daniele M.
    Ralchenko, Viktor G.
    Salvatori, Stefano
    IEEE ELECTRON DEVICE LETTERS, 2012, 33 (02) : 224 - 226
  • [46] Hybrid Pixel Detectors for gamma/X-ray imaging
    Hatzistratis, D.
    Theodoratos, G.
    Zografos, V.
    Kazas, I.
    Loukas, D.
    Lambropoulos, C. P.
    INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015), 2015, 637
  • [47] X-ray imaging detectors advance plasma research
    Reinke, Matthew
    PHYSICS TODAY, 2013, 66 (07) : 11 - 11
  • [48] PSF measurement of imaging detectors with an x-ray microbeam
    Takano, H
    Suzuki, Y
    Uesugi, K
    Takeuchi, A
    Yagi, N
    X-RAY MICRO- AND NANO-FOCUSING: APPLICATIONS AND TECHNIQUES II, 2001, 4499 : 126 - 133
  • [49] X-ray fluorescence tomography using imaging detectors
    Meng, Ling-Jian
    Fu, Geng
    Li, Nan
    Newville, Matt
    Eng, Peter
    La Riviere, Patrick
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [50] Review of medical imaging with emphasis on X-ray detectors
    Hoheisel, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 215 - 224