Hierarchical energy management system with multiple operation modes for hybrid DC microgrid

被引:20
|
作者
Kaysal, Ahmet [1 ]
Koroglu, Selim [2 ]
Oguz, Yuksel [3 ]
机构
[1] Afyon Kocatepe Univ, Dept Elect Engn, TR-03200 Afyon, Turkey
[2] Pamukkale Univ, Dept Elect & Elect Engn, TR-20160 Denizli, Turkey
[3] Afyon Kocatepe Univ, Dept Elect & Elect Engn, TR-03200 Afyon, Turkey
关键词
Hierarchical energy management system; Multiple operation modes; Hybrid DC microgrid; Equivalent consumption minimization strategy; Optimization algorithms; ECONOMIC-DISPATCH; OPTIMIZATION; STRATEGY; MPPT;
D O I
10.1016/j.ijepes.2022.108149
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a developed energy management system (EMS) with a hierarchical three-level distributed control approach proposed for a photovoltaic/wind turbine/diesel generator with energy storage in an islanded hybrid DC microgrid (MG). In the hierarchical three-level control structure, the power to be transferred by the distributed energy sources (DER) is provided by controlling the converters in the primary control layer. The secondary control layer is used to achieve DC bus voltage restoration and increase current-sharing accuracy simultaneously. In the tertiary control layer, it is aimed to minimize the production cost by performing optimum load-sharing. For the operation of this control structure, a strategy is proposed to optimally manage the energy demand of the hybrid system autonomously under variable load conditions. The EMS with three different operating modes (Mode-I, Mode-II, Mode-III) is proposed to share power between DC MG sources optimally. In Mode-I, renewable energy sources (RES) are enabled to operate with MPPT operation. Energy consumption minimization strategy (ECMS)-based linear programming (LP), genetic algorithm (GA) and pattern search (PS) algorithms are used to minimize the fuel consumption and carbon emissions of the diesel generator (DG) in Mode-II operating Mode. In Mode-III operating mode, DG is not needed, and the power flow between DERs is optimized by using the fuzzy logic controller (FLC) and state machine control strategy (SMCS). The amount of fuel consumed, the cost of fuel consumption and ESS's SOC level are used as the EMS's performance criteria for the MG. The minimum fuel consumption of the DG is calculated as 2.328 L for the operation of LP-based ECMS, and the fuel cost, in this case, is found to be $3.26. Considering the charging of the ESS, the highest SOC level is achieved with 64.87% for the PS-based ECMS-SMCS combination. By considering fuel minimization and SOC level together, it can be seen that the best result is achieved with the LP-based ECMS-SMCS combination.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] A dual mode wind turbine operation with hybrid energy storage system for electricity generation at constant voltage in an islanded microgrid
    Dhar, Pinaki
    Chakraborty, Niladri
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (13) : 18885 - 18902
  • [42] Hierarchical Management Control Based on Equivalent Fitting Circle and Equivalent Energy Consumption Method for Multiple Fuel Cells Hybrid Power System
    Yan, Yu
    Li, Qi
    Chen, Weirong
    Huang, Wenqiang
    Liu, Jiawei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (04) : 2786 - 2797
  • [43] Energy Management for Hybrid AC/DC Distribution System With Microgrid Clusters Using Non-Cooperative Game Theory and Robust Optimization
    Fu, Yang
    Zhang, Zhiquan
    Li, Zhenkun
    Mi, Yang
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (02) : 1510 - 1525
  • [44] Temporally Coordinated Energy Management for AC/DC Hybrid Microgrid Considering Dynamic Conversion Efficiency of Bidirectional AC/DC Converter
    Wei, Bin
    Han, Xiaoqing
    Wang, Peng
    Yu, Hao
    Li, Wen
    Guo, Lingjuan
    IEEE ACCESS, 2020, 8 : 70878 - 70889
  • [45] Optimization of CCHP integrated with multiple load, replenished energy, and hybrid storage in different operation modes
    Dai, Yiru
    Zeng, Yipu
    ENERGY, 2022, 260
  • [46] An Energy Management System for Residential Autonomous DC Microgrid Using Optimized Fuzzy Logic Controller Considering Economic Dispatch
    Al-Sakkaf, Shehab
    Kassas, Mahmoud
    Khalid, Muhammad
    Abido, Mohammad A.
    ENERGIES, 2019, 12 (08)
  • [47] Design and Implementation of an Energy-Management System for a Grid-Connected Residential DC Microgrid
    Padilla-Medina, Alfredo
    Perez-Pinal, Francisco
    Jimenez-Garibay, Alonso
    Vazquez-Lopez, Antonio
    Martinez-Nolasco, Juan
    ENERGIES, 2020, 13 (16)
  • [48] Rule-based energy management system for autonomous voltage stabilization in standalone DC microgrid
    Safder, Muhammad Umair
    Hossain, Md Alamgir
    Sanjari, Mohammad J.
    Lu, Junwei
    ENERGY SCIENCE & ENGINEERING, 2024, 12 (10) : 4278 - 4296
  • [49] Energy management strategy for standalone DC microgrid system with photovoltaic/fuel cell/battery storage
    Gugulothu, Ramesh
    Nagu, Bhookya
    Pullaguram, Deepak
    JOURNAL OF ENERGY STORAGE, 2023, 57
  • [50] Microgrid Energy Management during High-Stress Operation
    Price, Thomas
    Parker, Gordon
    Vaucher, Gail
    Jane, Robert
    Berman, Morris
    ENERGIES, 2022, 15 (18)