United States energy and CO2 savings potential from deployment of near-infrared electrochromic window glazings

被引:127
作者
DeForest, Nicholas [1 ]
Shehabi, Arman [1 ]
O'Donnell, James [1 ,2 ]
Garcia, Guillermo [3 ]
Greenblatt, Jeffery [1 ]
Lee, Eleanor S. [1 ]
Selkowitz, Stephen [1 ]
Milliron, Delia J. [4 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Environm Energy Technol Div, Berkeley, CA 94720 USA
[2] Univ Coll Dublin, Sch Mech & Mat Engn, Elect Res Ctr, Dublin 4, Ireland
[3] Heliotrope Technol, Berkeley, CA 94705 USA
[4] Univ Texas Austin, McKetta Dept Chem Engn, Austin, TX 78712 USA
关键词
Dynamic windows; Electrochromic glazings; NIR-Switching; National energy reduction; Solar heat gain; PERFORMANCE;
D O I
10.1016/j.buildenv.2015.02.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a simulation study of the energy and CO2 benefits of a transparent, near-infrared switching electrochromic (NEC) glazing for building applications. NEC glazings are an emerging dynamic window technology that can modulate the transmission of NIR heat without affecting transmission of visible light. In this study, a hypothetical NEC glazing is simulated on clear and tinted glass in six building type models in 16 U.S. climate regions using Energy Plus 7.1. The total annual energy consumption for lighting, heating, cooling, and ventilation for the NEC glazings are compared with high performance static windows and conventional tungsten-oxide EC glazings. Using regional CO2 intensities and building stock totals, the results from individual building model simulations are scaled up to national totals. The U.S. national savings from NEC deployment is found to be 167 TWh/yr (600 PJ/yr) compared to the existing building stock, but only 8 TWh/yr (29 PJ/yr) or 1.56 million tonnes of CO2 per year when compared to high performance static glazings with lighting controls installed. NEC performance varied significantly by building type and location. This analysis reveals that 50% of the total energy savings can be realized by deploying NEC glazings in only 18% of the total window stock, and 75% of the savings in only 39% of the stock. The best performing locations include medium offices and midrise residential buildings in northern climates, where energy savings per unit window area range from 50 to 200 kWh/m(2)-yr. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:107 / 117
页数:11
相关论文
共 31 条
[1]  
[Anonymous], ENERGYPLUS TEST VAL
[2]  
[Anonymous], 2011, U.S. Department of Energy commercial reference building models of the national building stock
[3]  
[Anonymous], COMM BUILD EN CONS S
[4]  
[Anonymous], 2012, ANN ENERGY OUTLOOK 2
[5]  
[Anonymous], 2012, ENERGYPLUS 7 1 BUILD
[6]  
[Anonymous], EGRID2012 VERS 1 0
[7]  
Apte J., 2003, ASHRAE Transactions, V109, P871
[8]  
Arasteh D., 2006, ZERO ENERGY WINDOWS
[9]  
Belzer DB, 2010, PNNL19637
[10]   EnergyPlus: creating a new-generation building energy simulation program [J].
Crawley, DB ;
Lawrie, LK ;
Winkelmann, FC ;
Buhl, WF ;
Huang, YJ ;
Pedersen, CO ;
Strand, RK ;
Liesen, RJ ;
Fisher, DE ;
Witte, MJ ;
Glazer, J .
ENERGY AND BUILDINGS, 2001, 33 (04) :319-331