Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study

被引:0
作者
Meng, Yang [1 ]
Shaw, Chris C. [1 ]
Liu, Xinming [1 ]
Altunbas, Mustafa C. [1 ]
Wang, Tianpeng [1 ]
Chen, Lingyun [1 ]
Tu, Shu-Ju [1 ]
Kappadath, S. Cheenu [1 ]
Lai, Chao-Jen [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Digital Imaging Res Lab, Houston, TX 77030 USA
来源
MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2006年 / 6142卷
关键词
cone beam CT; CCD; flat panel; small animal imaging;
D O I
10.1117/12.656690
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To compare two detector systems - one based on the charge-coupled device (CCD) and image amplifier, the other based on a-Si/CsI flat panel, for cone beam computed-tomography (CT) imaging of small animals. A high resolution, high framing rate detector system for the cone beam CT imaging of small animals was developed. The system consists of a 2048x3072x12 bit CCD optically coupled to an image amplifier and an x-ray phosphor screen. The CCD has an intrinsic pixel size of 12 gin but the effective pixel size can be adjusted through the magnification adjustment of the optical coupling systems. The system is used in conjunction with an x-ray source and a rotating stage for holding and rotating the scanned object in the cone beam CT imaging experiments. The advantages of the system include but are not limited to the ability to adjust the effective pixel size and to achieve extremely high spatial resolution and temporal resolution. However, the need to use optical coupling compromises the detective quanta efficiency (DQE) of the system. In this paper, the imaging characteristics of the system were presented and compared with those of an aSi/CsI flat-panel detector system.
引用
收藏
页数:6
相关论文
共 22 条
  • [1] Calibration procedures for charge-coupled device x-ray detectors
    Barna, SL
    Tate, MW
    Gruner, SM
    Eikenberry, EF
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07) : 2927 - 2934
  • [2] Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography
    Båth, M
    Sund, P
    Månsson, LG
    [J]. MEDICAL PHYSICS, 2002, 29 (10) : 2286 - 2297
  • [3] Task-based lens design with application to digital mammography
    Chen, LY
    Barrett, HH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (01) : 148 - 167
  • [4] A comparison of the imaging properties of CCD-based devices used for small field digital mammography
    Evans, DS
    Workman, A
    Payne, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) : 117 - 135
  • [5] A comparison of x-ray detectors for mouse CT imaging
    Goertzen, AL
    Nagarkar, V
    Street, RA
    Paulus, MJ
    Boone, JM
    Cherry, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23) : 5251 - 5265
  • [6] Charge-coupled device area x-ray detectors
    Gruner, SM
    Tate, MW
    Eikenberry, EF
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) : 2815 - 2842
  • [7] An evaluation of the signal and noise characteristics of four CCD-based film digitizers
    Hangiandreou, NJ
    O'Connor, TJ
    Felmlee, JP
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2020 - 2026
  • [8] System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography
    Hejazi, S
    Trauernicht, DP
    [J]. MEDICAL PHYSICS, 1997, 24 (02) : 287 - 297
  • [9] Diagnosis of gastric cancers: Comparison of conventional radiography and digital radiography with a 4 million-pixel charge-coupled device
    Iinuma, G
    Ushio, K
    Ishikawa, T
    Nawano, S
    Sekiguchi, R
    Satake, M
    [J]. RADIOLOGY, 2000, 214 (02) : 497 - 502
  • [10] Visibility of simulated microcalcifications - A hardcopy-based comparison of three mammographic systems
    Lai, CJ
    Shaw, CC
    Whitman, GJ
    Johnston, DA
    Yang, WT
    Selinko, V
    Arribas, E
    Dogan, B
    Kappadath, SC
    [J]. MEDICAL PHYSICS, 2005, 32 (01) : 182 - 194