Confirmation of quasi-static approximation in SAR evaluation for a wireless power transfer system

被引:82
作者
Hirata, Akimasa [1 ]
Ito, Fumihiro [1 ]
Laakso, Ilkka [1 ]
机构
[1] Nagoya Inst Technol, Dept Comp Sci & Engn, Showa Ku, Nagoya, Aichi 4668555, Japan
关键词
MAGNETIC-FIELDS; ELECTRIC-FIELD; HUMAN-BODY; MODEL; EXPOSURE;
D O I
10.1088/0031-9155/58/17/N241
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present study discusses the applicability of the magneto-quasi-static approximation to the calculation of the specific absorption rate (SAR) in a cylindrical model for a wireless power transfer system. Resonant coils with different parameters were considered in the 10 MHz band. A two-step quasi-static method that is comprised of the method of moments and the scalar-potential finite-difference methods is applied, which can consider the effects of electric and magnetic fields on the induced SAR separately. From our computational results, the SARs obtained from our quasi-static method are found to be in good agreement with full-wave analysis for different positions of the cylindrical model relative to the wireless power transfer system, confirming the applicability of the quasi-static approximation in the 10 MHz band. The SAR induced by the external electric field is found to be marginal as compared to that induced by the magnetic field. Thus, the dosimetry for the external magnetic field, which may be marginally perturbed by the presence of biological tissue, is confirmed to be essential for SAR compliance in the 10 MHz band or lower. This confirmation also suggests that the current in the coil rather than the transferred power is essential for SAR compliance.
引用
收藏
页码:N241 / N249
页数:9
相关论文
共 21 条
  • [1] Ahlbom A, 1998, HEALTH PHYS, V74, P494
  • [2] Amano T H H, 2011, P IEICE SOC C, pB
  • [3] [Anonymous], 2019, IEEEC951
  • [4] A Huygens subgridding for the FDTD method
    Berenger, Jean-Pierre
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2006, 54 (12) : 3797 - 3804
  • [5] Evaluation of Wireless Resonant Power Transfer Systems With Human Electromagnetic Exposure Limits
    Christ, Andreas
    Douglas, Mark G.
    Roman, John M.
    Cooper, Emily B.
    Sample, Alanson P.
    Waters, Benjamin H.
    Smith, Joshua R.
    Kuster, Niels
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (02) : 265 - 274
  • [6] Assessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
    Christ, Andreas
    Douglas, Mark
    Nadakuduti, Jagadish
    Kuster, Niels
    [J]. PROCEEDINGS OF THE IEEE, 2013, 101 (06) : 1482 - 1493
  • [7] FEKO Stellenbosch South Africa, 2011, EL SOFTW SYST EMSS
  • [8] Intercomparison of induced fields in Japanese male model for ELF magnetic field exposures: effect of different computational methods and codes
    Hirata, Akimasa
    Yamazaki, Kenichi
    Hamada, Shoji
    Kamimura, Yoshitsugu
    Tarao, Hiroo
    Wake, Kanako
    Suzuki, Yukihisa
    Hayashi, Noriyuki
    Fujiwara, Osamu
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 138 (03) : 237 - 244
  • [9] Estimation of Whole-Body Average SAR in Human Models Due to Plane-Wave Exposure at Resonance Frequency
    Hirata, Akimasa
    Fujiwara, Osamu
    Nagaoka, Tomoaki
    Watanabe, Soichi
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2010, 52 (01) : 41 - 48
  • [10] A consideration of electro-magnetic-resonant coupling mode in wireless power transmission
    Hirayama, Hiroshi
    Ozawa, Toshiyuki
    Hiraiwa, Yosuke
    Kikuma, Nobuyoshi
    Sakakibara, Kunio
    [J]. IEICE ELECTRONICS EXPRESS, 2009, 6 (19): : 1421 - 1425