共 27 条
Intraocular Pressure after Implantation of the Visian Implantable Col lamer Lens With CentraFLOW Without Iridotomy
被引:77
作者:
Higueras-Esteban, Alejandro
[1
]
Ortiz-Gomariz, Amanda
[1
]
Gutierrez-Ortega, Ramon
[1
]
Villa-Collar, Cesar
[2
]
Abad-Montes, Juan P.
[1
]
Fernandes, Paulo
[3
]
Gonzalez-Meijome, Jose M.
[3
]
机构:
[1] Univ Europea Madrid, Dept Opt & Optometry, Madrid, Spain
[2] Novovis Clin Dr Gutierrez, Murcia, Spain
[3] Univ Minho, Ctr Phys, Clin & Expt Optometry Res Lab, P-4710057 Braga, Portugal
关键词:
ADMINISTRATION CLINICAL-TRIAL;
ANTERIOR-CHAMBER DEPTH;
COLLAMER LENS;
HIGH MYOPIA;
CONTACT-LENS;
LASER IRIDOTOMY;
MODERATE;
SURGERY;
COMPLICATIONS;
LASIK;
D O I:
10.1016/j.ajo.2013.05.018
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE: To compare the intraocular pressure (TOP) values during a 3-month period after implantation of the new Visian Implantable Col lamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN: Retrospective cohort study. METHODS: This study included 17 eyes implanted with the ICL V4b model and 18 eyes implanted with the ICL V4c model. The mean preoperative spherical equivalent refractions were -7.48 +/- 5.00 diopters and -8.66 +/- 4.2 diopters, respectively. We compared the best-corrected distance visual acuity before surgery with the uncorrected distance visual acuity after surgery. The intraocular pressure (TOP) was measured 1 week, 1 month, and 3 months after surgery. The central vault at 3 months was measured using optical coherence tomography. RESULTS: Three months after surgery, the mean uncorrected distance visual acuities were -0.09 +/- 0.12 logarithm of the minimal angle of resolution units with the V4b and -0.07 +/- 0.11 logarithm of the minimal angle of resolution units with the V4c. The mean distances between the ICL and the anterior crystalline lens surface were 557 +/- 224 mu m and 528 +/- 268 mu m for the V4b and V4c, respectively (P = .73). After 1 week and 1 month, the mean IOPs were 13.7 and 13.3 mm Hg and 14.7 and 15.1 mm Hg, respectively. There were no significant differences in TOP within or between groups during the follow-up period (P > .05, for all comparisons). CONCLUSIONS: The new ICL with the CentraFLOW design seems to provide similar results as its predecessors for the correction of moderate to high myopia and maintenance of safe TOP levels without iridotomy. ((C) 2013 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:800 / 805