Intraocular Pressure after Implantation of the Visian Implantable Col lamer Lens With CentraFLOW Without Iridotomy

被引:77
作者
Higueras-Esteban, Alejandro [1 ]
Ortiz-Gomariz, Amanda [1 ]
Gutierrez-Ortega, Ramon [1 ]
Villa-Collar, Cesar [2 ]
Abad-Montes, Juan P. [1 ]
Fernandes, Paulo [3 ]
Gonzalez-Meijome, Jose M. [3 ]
机构
[1] Univ Europea Madrid, Dept Opt & Optometry, Madrid, Spain
[2] Novovis Clin Dr Gutierrez, Murcia, Spain
[3] Univ Minho, Ctr Phys, Clin & Expt Optometry Res Lab, P-4710057 Braga, Portugal
关键词
ADMINISTRATION CLINICAL-TRIAL; ANTERIOR-CHAMBER DEPTH; COLLAMER LENS; HIGH MYOPIA; CONTACT-LENS; LASER IRIDOTOMY; MODERATE; SURGERY; COMPLICATIONS; LASIK;
D O I
10.1016/j.ajo.2013.05.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the intraocular pressure (TOP) values during a 3-month period after implantation of the new Visian Implantable Col lamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN: Retrospective cohort study. METHODS: This study included 17 eyes implanted with the ICL V4b model and 18 eyes implanted with the ICL V4c model. The mean preoperative spherical equivalent refractions were -7.48 +/- 5.00 diopters and -8.66 +/- 4.2 diopters, respectively. We compared the best-corrected distance visual acuity before surgery with the uncorrected distance visual acuity after surgery. The intraocular pressure (TOP) was measured 1 week, 1 month, and 3 months after surgery. The central vault at 3 months was measured using optical coherence tomography. RESULTS: Three months after surgery, the mean uncorrected distance visual acuities were -0.09 +/- 0.12 logarithm of the minimal angle of resolution units with the V4b and -0.07 +/- 0.11 logarithm of the minimal angle of resolution units with the V4c. The mean distances between the ICL and the anterior crystalline lens surface were 557 +/- 224 mu m and 528 +/- 268 mu m for the V4b and V4c, respectively (P = .73). After 1 week and 1 month, the mean IOPs were 13.7 and 13.3 mm Hg and 14.7 and 15.1 mm Hg, respectively. There were no significant differences in TOP within or between groups during the follow-up period (P > .05, for all comparisons). CONCLUSIONS: The new ICL with the CentraFLOW design seems to provide similar results as its predecessors for the correction of moderate to high myopia and maintenance of safe TOP levels without iridotomy. ((C) 2013 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:800 / 805
页数:6
相关论文
共 27 条
  • [1] Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Lisa, Carlos
    Fernandes, Paulo
    Jorge, Jorge
    Montes Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) : 46 - 53
  • [2] Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
    Alfonso, Jose F.
    Lisa, Carlos
    Palacios, Ana
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 978 - 983
  • [3] Phakic anterior chamber lenses for the correction of myopia -: A 7-year cumulative analysis in complications in 283 cases
    Alió, JL
    de la Hoz, F
    Pérez-Santonja, JJ
    Ruiz-Moreno, JM
    Quesada, JA
    [J]. OPHTHALMOLOGY, 1999, 106 (03) : 458 - 466
  • [4] Collamer intraocular contact lens to correct high myopia
    Assetto, V
    Benedetti, S
    Pesando, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (05) : 551 - 556
  • [6] Phakic posterior chamber intraocular lens pupillary block
    Bylsma, SS
    Zalta, AH
    Foley, E
    Osher, RH
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) : 2222 - 2228
  • [7] Randomised trial of sequential pretreatment for Nd:YAG laser iridotomy in dark irides
    de Silva, D. Julian
    Day, Alexander C.
    Bunce, Catey
    Gazzard, Gus
    Foster, Paul J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (02) : 263 - 266
  • [8] Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Madrid-Costa, David
    Ferrer-Blasco, Teresa
    Jorge, Jorge
    Montes-Mico, Robert
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) : 765 - 776
  • [9] Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation
    Gonvers, M
    Bornet, C
    Othenin-Girard, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) : 918 - 924
  • [10] Cataract development associated with collagen copolymer posterior chamber phakic intraocular lenses: Clinicopathological correlation
    Khalifa, Yousuf M.
    Moshirfar, Majid
    Mifflin, Mark D.
    Kamae, Kandon
    Mamalis, Nick
    Werner, Liliana
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10) : 1768 - 1774