Multiplex bead array assays: Performance evaluation and comparison of sensitivity to ELISA

被引:425
作者
Elshal, MF [1 ]
McCoy, JP [1 ]
机构
[1] NHLBI, NIH, Bethesda, MD 20892 USA
关键词
cytokine; lumnex; X-map; multiplex; ELISA;
D O I
10.1016/j.ymeth.2005.11.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of soluble cytokines and other analytes in serum and plasma is becoming increasingly important in the study and management of many diseases. As a result, there is a growing demand for rapid, precise, and cost-effective measurement of such analytes in both clinical and research laboratories. Multiplex bead array assays provide quantitative measurement of large numbers of analytes using an automated 96-well plate format. Enzyme-linked immunosorbent assay (ELISAs) have long been the standard for quantitative analysis of cytokines and other biomarkers, but are not well suited for high throughput multiplex analyses. However, prior to replacement of ELISA assays with multiplex bead array assays, there is a need to know how comparable these two methods are for quantitative analyses. A number of published studies have compared these two methods and it is apparent that certain elements of these assays, such as the clones of monoclonal antibodies used for detection and reporting, are pivotal in obtaining similar results front both assays. By careful consideration of these variables, it should be possible to utilize multiplex bead array assays in lieu of ELISAs for studies requiring high throughput analysis of numerous analytes. Crown copyright (c) 2006 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 27 条
  • [11] Hildesheim A, 2002, CANCER EPIDEM BIOMAR, V11, P1477
  • [12] Rapid simultaneous measurement of multiple cytokines using 100 μl sample volumes -: association with neonatal sepsis
    Hodge, G
    Hodge, S
    Haslam, R
    McPhee, A
    Sepulveda, H
    Morgan, E
    Nicholson, I
    Zola, H
    [J]. CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 2004, 137 (02) : 402 - 407
  • [13] QUANTITATIVE SINGLE CELL ANALYSIS AND SORTING
    HORAN, PK
    WHEELESS, LL
    [J]. SCIENCE, 1977, 198 (4313) : 149 - 157
  • [14] Multiplexed microsphere-based flow cytometric immunoassays for human cytokines
    Kellar, KL
    Douglass, JP
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 279 (1-2) : 277 - 285
  • [15] Kettman JR, 1998, CYTOMETRY, V33, P234, DOI 10.1002/(SICI)1097-0320(19981001)33:2<234::AID-CYTO19>3.0.CO
  • [16] 2-V
  • [17] Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturers
    Khan, SS
    Smith, MS
    Reda, D
    Suffredini, AF
    McCoy, JP
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2004, 61B (01) : 35 - 39
  • [18] Circulating angiogenic growth factor levels in mice bearing human tumors using Luminex Multiplex technology
    Kristan, KA
    Mann, L
    Cox, K
    Treadway, P
    Iversen, P
    Chen, YF
    Teicher, BA
    [J]. CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2003, 51 (04) : 321 - 327
  • [19] LARSEN SA, 1990, MANUAL TESTS SYPHILI, P191
  • [20] Multiplexed analysis of biomarkers related to obesity and the metabolic syndrome in human plasma, using the luminex-100 system
    Liu, MY
    Xydakis, AM
    Hoogeveen, RC
    Jones, PH
    Smith, EOB
    Nelson, KW
    Ballantyne, CM
    [J]. CLINICAL CHEMISTRY, 2005, 51 (07) : 1102 - 1109