Purpose: Development, application and evaluation of a CT-guided implantation technique and a fully CT-based treatment planning procedure for brachytherapy. Methods and Materials: A brachytherapy procedure based on CT-guided implantation technique and CT-based treatment planning has been developed and clinical evaluated. For this purpose a software system (PROMETHEUS) for the 3D reconstruction of brachytherapy catheters and patient anatomy using only CT scans has been developed. An interface for the Nucletron PLATO BPS treatment planning system for optimization and calculation of dose distribution has been devised. The planning target volume(s) are defined as sets of points using contouring tools and are used for optimization of the 3D dose distribution. Dose-volume histogram based analysis of the dose distribution (COIN analysis) enables a clinically realistic evaluation of the brachytherapy application to be made. The CT-guided implantation of catheters and the CT-based treatment planning procedure has been performed for interstitial brachytherapy and for different tumor sites in 197 patients between 1996 and 1997. Results: The accuracy of the CT reconstruction was tested using first a quality assurance phantom and second, a simulated interstitial implant of 12 needles. These were compared with the results of reconstruction using radiographs. Both methods gave comparable results with regard to accuracy, but the CT based reconstruction was faster. Clinical feasibility was proved in pre-irradiated recurrences of brain tumors, in pretreated recurrences or metastatic disease, and in breast carcinomas. The tumor volumes treated were in the range 5.1 to 2,741 cm(3). Analysis of implant quality showed a slightly significant lower COIN value for the bone implants, but no differences with respect to the planning target volume. Conclusions: The Offenbach system, incorporating the PROMETHEUS software for interstitial HDR brachytherapy has proved to be extremely valuable in routine clinical practice for many tumor sites. Our CT-guided implantation technique together with a fully CT-based planning system has enabled conformal brachytherapy treatment to become routine.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 50 条
  • [31] Contour-Based Deformable Image Registration and Dose Accumulation in CT-based Hybrid HDR Brachytherapy for Cervical Cancer
    Shen, X.
    Velten, C.
    Hsu, S. H.
    Basavatia, A.
    Mehta, K. J.
    Tome, W. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E339 - E340
  • [32] single application CT-based interstitial high-dose-rate brachytherapy for cervical cancer
    Yap, E.
    Bacorro, W.
    Ortin, T. Sy
    Jainar, C.
    Dumago, M.
    Bojador, M.
    Cabrera, S.
    Jacomina, L.
    Gonzalez, G.
    Mariano, J.
    Antonio, L.
    Bautista, A.
    Genson, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1937 - S1938
  • [33] Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer
    Kim, Y
    Hsu, I
    Pouliot, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1957 - 1957
  • [34] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levin, D.
    Menchel, J.
    Symon, Z.
    Pfeffer, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S323 - S323
  • [35] Comparison of orthogonal radiography and 3D CT-based treatment planning in HDR brachytherapy of cervix cancer
    Alezra, D.
    Rabin, T.
    Levine, D.
    Menhel, J.
    Symon, Z.
    Pfeffer, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S407 - S408
  • [36] CT-based treatment planning in mammosite brachytherapy
    Cattani, F
    Ciocca, M
    Lazzari, R
    Vavassori, A
    Canino, P
    Ballardini, B
    Piazzi, V
    Gennari, R
    Costa, A
    Orecchia, R
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S69 - S69
  • [37] Inter-fractional balloon variation in Mammosite HDR brachytherapy: Dosimetric analysis on 200 CT-based plans
    Kim, Y.
    Johnson, M.
    Trombetta, M. G.
    Parda, D. S.
    Miften, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S638 - S639
  • [38] HDR brachytherapy dose errors resulting from geometric distortion of MR used for fusion in CT-based planning
    Keough, W.
    Nailon, W. H.
    Zahra, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S330 - S330
  • [39] CT-based intra-cavitary high dose rate (HDR) brachytherapy for cervical cancer: planning and QA
    Wang, B.
    Zhu, Y.
    Yeo, I.
    Kwon, A.
    Henson, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2431 - 2431
  • [40] PET/CT Guided Dose Redistribution for HDR Interstitial Brachytherapy of Cervical Cancer
    Yao, R.
    Templeton, A.
    Chu, J.
    Liao, Y.
    Turian, J.
    Gielda, B.
    Zusag, T.
    MEDICAL PHYSICS, 2010, 37 (06) : 3390 - +