CT-based interstitial HDR brachytherapy

被引:59
作者
Kolotas, C [1 ]
Baltas, D [1 ]
Zamboglou, N [1 ]
机构
[1] Stadt Kliniken, Strahlenklin, D-63069 Offenbach, Germany
关键词
interstitial HDR brachytherapy; CT; conformal treatment;
D O I
10.1007/s000660050031
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Development, application and evaluation of a CT-guided implantation technique and a fully CT-based treatment planning procedure for brachytherapy. Methods and Materials: A brachytherapy procedure based on CT-guided implantation technique and CT-based treatment planning has been developed and clinical evaluated. For this purpose a software system (PROMETHEUS) for the 3D reconstruction of brachytherapy catheters and patient anatomy using only CT scans has been developed. An interface for the Nucletron PLATO BPS treatment planning system for optimization and calculation of dose distribution has been devised. The planning target volume(s) are defined as sets of points using contouring tools and are used for optimization of the 3D dose distribution. Dose-volume histogram based analysis of the dose distribution (COIN analysis) enables a clinically realistic evaluation of the brachytherapy application to be made. The CT-guided implantation of catheters and the CT-based treatment planning procedure has been performed for interstitial brachytherapy and for different tumor sites in 197 patients between 1996 and 1997. Results: The accuracy of the CT reconstruction was tested using first a quality assurance phantom and second, a simulated interstitial implant of 12 needles. These were compared with the results of reconstruction using radiographs. Both methods gave comparable results with regard to accuracy, but the CT based reconstruction was faster. Clinical feasibility was proved in pre-irradiated recurrences of brain tumors, in pretreated recurrences or metastatic disease, and in breast carcinomas. The tumor volumes treated were in the range 5.1 to 2,741 cm(3). Analysis of implant quality showed a slightly significant lower COIN value for the bone implants, but no differences with respect to the planning target volume. Conclusions: The Offenbach system, incorporating the PROMETHEUS software for interstitial HDR brachytherapy has proved to be extremely valuable in routine clinical practice for many tumor sites. Our CT-guided implantation technique together with a fully CT-based planning system has enabled conformal brachytherapy treatment to become routine.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 25 条
  • [11] KOLOTAS C, 1997, NEW DEV INTERSTITIAL, P143
  • [12] KOVACS G, 1997, NEW DEV INT REMOTE C, P52
  • [13] LEVENDAG P, 1997, NEW DEV INTERSTITIAL, P128
  • [14] CT-ASSISTED ASSESSMENT OF BLADDER AND RECTUM DOSE IN GYNECOLOGICAL IMPLANTS
    LING, CC
    SCHELL, MC
    WORKING, KR
    JENTZSCH, K
    HARISIADIS, L
    CARABELL, S
    ROGERS, CC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (10): : 1577 - 1582
  • [15] NARAYANA V, 1997, INT J RAD ONCOL BIOL, V39, P341
  • [16] *NAT EL MAN ASS, 1993, NEMA STAND PUBL
  • [17] PFANDNER K, 1993, BRACHYTHERAPY GERMAN, P215
  • [18] Quimby EH, 1932, AM J ROENTGENOL RADI, V27, P18
  • [19] A CT-BASED EVALUATION METHOD FOR PERMANENT IMPLANTS - APPLICATION TO PROSTATE
    ROY, JN
    WALLNER, KE
    HARRINGTON, PJ
    LING, CC
    ANDERSON, LL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (01): : 163 - 169
  • [20] A CT-COMPATIBLE VERSION OF THE FLETCHER SYSTEM INTRACAVITARY APPLICATOR - CLINICAL-APPLICATION AND 3-DIMENSIONAL TREATMENT PLANNING
    SCHOEPPEL, SL
    FRAASS, BA
    HOPKINS, MP
    LAVIGNE, ML
    LICHTER, AS
    MCSHAN, DL
    NOFFSINGER, S
    PEREZTAMAYO, C
    ROBERTS, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (05): : 1103 - 1109