Impact of Patient-Prosthesis Mismatch in the Aortic Position: Twenty-Year Experience with Korean Patients

被引:0
|
作者
Jeong, Dong Seop [1 ]
Chang, Hyoung Woo [2 ]
Kim, Kyung-Hwan [2 ]
Ahn, Hyuk [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, Seoul 110744, South Korea
关键词
LONG-TERM SURVIVAL; DOPPLER-ECHOCARDIOGRAPHIC EVALUATION; LEFT-VENTRICULAR DYSFUNCTION; VALVE-REPLACEMENT; HEMODYNAMIC PERFORMANCE; MORTALITY; STENOSIS; VALIDATION; GUIDELINES; ANNULUS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The impact of patient-prosthesis mismatch (PPM) on clinical outcomes following aortic valve replacement (AVR) remains controversial. The study aim was to evaluate the impact of PPM on long-term clinical outcomes following AVR. Methods: Between January 1987 and September 2007, a total of 198 consecutive patients (mean age 59.6 +/- 10.5 years; range: 31-85 years) underwent isolated AVR for pure aortic stenosis at the authors' institutions. PPM was defined as an indexed effective orifice area (EOAI) <0.85cm(2)/m(2), and was present in 45 patients (22.7%). The mean follow up duration was 102.6 +/- 71.6 months (maximum 270 months). Results: The early mortality was 1.5% (n = 3). The late mortality was similar in both the PPM and non-PPM groups (4.4% versus 4.7%; p = 0.950). The left ventricular mass index during follow up was higher in the PPM group (128.5 +/- 36.1 versus 114.5 +/- 39.1 g/m(2), p = 0.037). Freedom from cardiac-related mortality at 15 years was 86.5 +/- 4.3% in the non-PPM group, and 92.9 +/- 4.9% in the PPM group (p = 0.282). Freedom from heart failure events at 15 years was 74.6 +/- 6.6% in the non-PPM group and 61.6 +/- 8.5% in the PPM group (p = 0.028). Predictors of heart failure events were female gender (p = 0.041, hazards ratio (HR) = 2.5, 95% confidence interval (CI) = 1.1-5.9) and PPM (p = 0.001, HR = 5.1, 95% CI = 1.9-13.7). Conclusion: In AVR patients with pure aortic stenosis, PPM, when defined by the threshold value of EOAI <0.85 cm(2)/m(2), was not associated with differences in cardiac-related mortality. However, PPM was related to an increased incidence of postoperative heart failure events.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [31] Factors Determining Patient-Prosthesis Mismatch after Aortic Valve Replacement - A Prospective Cohort Study
    Bonderman, Diana
    Graf, Alexandra
    Kammerlander, Andreas A.
    Kocher, Alfred
    Laufer, Guenter
    Lang, Irene M.
    Mascherbauer, Julia
    PLOS ONE, 2013, 8 (12):
  • [32] Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses
    Seiffert, Moritz
    Conradi, Lenard
    Baldus, Stephan
    Knap, Malgorzata
    Schirmer, Johannes
    Franzen, Olaf
    Koschyk, Dietmar
    Meinertz, Thomas
    Reichenspurner, Hermann
    Treede, Hendrik
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (03) : 617 - 624
  • [33] Impact of New York Heart Association classification, advanced age and patient-prosthesis mismatch on outcomes in aortic valve replacement surgery
    Zapolanski, Alex
    Mak, Andrew W. C.
    Ferrari, Giovanni
    Johnson, Christopher
    Shaw, Richard E.
    Brizzio, Mariano E.
    Sperling, Jason S.
    Grau, Juan B.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (03) : 371 - 376
  • [34] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [35] Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients
    Barros de Oliveira Sa, Michel Pompeu
    Barros de Carvalho, Martinha Millianny
    Sobral Filho, Dario Celestino
    Pereira Cavalcanti, Luiz Rafael
    Rayol, Sergio da Costa
    Silva Diniz, Roberto Gouvea
    Menezes, Alexandre Motta
    Clavel, Marie-Annick
    Pibarot, Philippe
    Lima, Ricardo Carvalho
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) : 44 - 54
  • [36] Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement
    Mannacio, Vito A.
    Mannacio, Luigi
    Antignano, Anita
    Pinna, Giovanni B.
    Giordano, Raffaele
    Mottola, Michele
    Iannelli, Gabriele
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (05) : 366 - 373
  • [37] Does patient-prosthesis mismatch influence the results of combined aortic valve replacement and coronary bypass grafting?
    Mrowczynski, Wojciech
    Lutter, Georg
    Attmann, Tim
    Hoffmann, Grischa
    Quaden, Rene
    Cremer, Jochen
    Boening, Andreas
    KARDIOLOGIA POLSKA, 2009, 67 (08) : 865 - 874
  • [38] Aortic root enlargement to mitigate patient-prosthesis mismatch: do early adverse events justify reluctance?
    Haunschild, Josephina
    Scharnowski, Sven
    Mende, Meinhard
    von Aspern, Konstantin
    Misfeld, Martin
    Mohr, Friedrich-Wilhelm
    Borger, MichaelA.
    Etz, Christian D.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (02) : 335 - 342
  • [39] Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement: Analysis of the PARTNER Trials
    Thourani, Vinod H.
    Abbas, Amr E.
    Ternacle, Julien
    Hahn, Rebecca T.
    Makkar, Raj
    Kodali, Susheel K.
    George, Isaac
    Kapadia, Samir
    Svensson, Lars G.
    Szeto, Wilson Y.
    Herrmann, Howard C.
    Ailawadi, Gorav
    Leipsic, Jonathon
    Blanke, Philipp
    Webb, John
    Jaber, Wael A.
    Russo, Mark
    Malaisrie, S. Chris
    Yadav, Pradeep
    Clavel, Marie-Annick
    Khalique, Omar K.
    Weissman, Neil J.
    Douglas, Pamela
    Bax, Jeroen
    Dahou, Abdellaziz
    Xu, Ke
    Bapat, Vinayak
    Alu, Maria C.
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    ANNALS OF THORACIC SURGERY, 2024, 117 (06) : 1164 - 1171
  • [40] Influence of Patient-Prosthesis Mismatch in the Octogenarian Undergoing Surgery for Aortic Valve Replacement Due to Severe Stenosis
    Hernandez-Vaquero, Daniel
    Calvo, David
    Garcia, Jose M.
    Lozano, Inigo
    Morales, Carlos
    Luis Naya, Jose
    Moris, Cesar
    Llosa, Juan C.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2011, 64 (09): : 774 - 779