Quantum efficiency of the CCD camera (XIS) for the ASTRO-E mission

被引:8
作者
Katayama, H
Shouho, M
Kohmura, T
Katayama, K
Yoshita, K
Tsunemi, H
Kitamoto, S
Hayashida, K
Miyata, E
Hashimotodani, K
Koyama, K
Ricker, G
Bautz, MW
Foster, R
Kissel, S
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Osaka 5600043, Japan
[2] Kyoto Univ, Grad Sch Sci, Dept Phys, Sakyo Ku, Kyoto 6068502, Japan
[3] MIT, Ctr Space Res, Cambridge, MA 02139 USA
[4] Japan Sci & Technol Corp, CREST, Kawaguchi, Saitama 332, Japan
关键词
CCD; calibration; quantum efficiency; ASTRO-E;
D O I
10.1016/S0168-9002(99)00600-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We measured the optical and the X-ray transmission of the optical blocking filters for the X-ray Imaging Spectrometers (XISs) which are the X-ray CCD cameras of the ASTRO-E satellite. We conclude that the oxidation of the aluminum reduces the optical transmission down to similar to 60-70% of the theoretical value of the aluminum. We achieved optical transmission below 5 x 10(-5) in the range from 4000 to 9500 Angstrom by using aluminum thickness of 1200 Angstrom, while the theoretical calculation requires 800 Angstrom. The measurement of absolute quantum efficiency of XIS is also performed at several particular energies. We confirmed 20% quantum efficiency at 0.5 keV for the XIS engineering model (XIS EM). (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 5 条
[1]   The X-ray and optical performance of the flight filters for the JET-X telescope [J].
Castelli, CM ;
Watson, DJ ;
Wells, A ;
Kent, BJ ;
Barbera, M ;
Collura, A ;
Bavdaz, M .
EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 :384-391
[2]   Continuum x-ray source as a calibration system for charge coupled devices [J].
Hashimotodani, K ;
Toneri, T ;
Kitamoto, S ;
Tsunemi, H ;
Hayashida, K ;
Miyata, E ;
Katayama, K ;
Kohomura, T ;
Asakura, R ;
Koyama, K ;
Yamamoto, K ;
Miyaguchi, K ;
Suzuki, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) :392-395
[3]   Soft X-ray response of the proto-type CCD camera (XIS) for Astro-E [J].
Hayashida, K ;
Kitamoto, S ;
Miyata, E ;
Tsunemi, H ;
Hashimotodani, K ;
Katayama, K ;
Kohmura, T ;
Asakura, R ;
Yoshita, K ;
Katayama, H ;
Shouho, M ;
Koyoma, K ;
Tsuru, TG ;
Awaki, H ;
Dotani, T ;
Ozaki, M ;
Ricker, G ;
Doty, J ;
Bautz, M ;
Kissel, S ;
Foster, R .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 :278-290
[4]  
KOHMURA T, 1998, IN PRESS P BROAD BAN
[5]   Measurement of the subpixel structure of AXAF CCD's [J].
Pivovaroff, M ;
Jones, S ;
Bautz, M ;
Kissel, S ;
Prigozhin, G ;
Ricker, G ;
Tsunemi, H ;
Miyata, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) :164-175