The impact of handgrip exercise duty cycle on brachial artery flow-mediated dilation

被引:13
|
作者
King, Trevor J. [1 ]
Slattery, David J. [1 ]
Pyke, Kyra E. [1 ]
机构
[1] Queens Univ, Cardiovasc Stress Response Lab, Sch Kinesiol & Hlth Studies, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Endothelial function; Doppler ultrasound; Shear stress; Conduit artery; Retrograde shear stress; Oscillatory shear index; NITRIC-OXIDE; ENDOTHELIAL DYSFUNCTION; REACTIVE-HYPEREMIA; RETROGRADE FLOW; SHEAR; VASODILATION; DILATATION; MECHANISMS; MAGNITUDE; RESPONSES;
D O I
10.1007/s00421-013-2612-0
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Endothelial function is essential for vasoprotection and regulation of vascular tone. Using handgrip exercise (HGEX) to increase blood flow-associated shear stress is an increasingly popular method for assessing brachial artery endothelial function via flow-mediated dilation (FMD). However, different exercise duty cycles [ratio of handgrip relaxation: contraction (seconds)] produce different patterns of brachial artery shear stress with distinct antegrade/retrograde magnitudes. To determine the impact of HGEX duty cycle on brachial artery %FMD, three distinct duty cycles were employed while maintaining a uniform mean shear stress. Brachial artery diameter and mean blood velocity were assessed via echo and Doppler ultrasound in 16 healthy male subjects. Shear stress was estimated as shear rate (SR = blood velocity/brachial artery diameter) and the target mean SR during HGEX was 75 s(-1). Subjects performed three 6-min HGEX trials on each of 2 days (like trials averaged). In each trial, subjects performed one of the three randomly ordered HGEX duty cycles (1:1, 3:1, 5:1). %FMD was calculated from baseline to the end of HGEX and (subset N = 10) during each minute of HGEX. Data are mean +/- A SD. As intended, mean SR was uniform across duty cycles (6 min HGEX average: 72.9 +/- A 4.9s(-1), 72.6 +/- A 3.6s(-1), 72.8 +/- A 3.5 s(-1), p = 0.835), despite differences in antegrade/retrograde SR (p < 0.001). End-exercise %FMD (4.0 +/- A 1.3 %, 4.1 +/- A 2.2 %, 4.2 +/- A 1.4 %, p = 0.860) and %FMD during exercise (p = 0.939) were not different between duty cycles. These data indicate that the endothelium responds to the mean shear stress and is not specifically sensitive to the contraction/relaxation or retrograde shear stress created by a range of HGEX protocols.
引用
收藏
页码:1849 / 1858
页数:10
相关论文
共 50 条
  • [41] Influence of pregnancy and smoking on brachial artery flow-mediated dilation values and time until maximum response
    Nicolau, Luis G. C.
    Martins, Wellington P.
    Gallarreta, Francisco M. P.
    Lima, Jailson C.
    Mauad Filho, Francisco
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 284 (02) : 313 - 317
  • [42] Can a combination of handgrip exercise and prolonged forearm occlusion elicit a maximal brachial artery FMD response?
    Ku, Jennifer
    McEvoy, Alana
    Pyke, Kyra E.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2014, 114 (06) : 1297 - 1307
  • [43] Remote ischemic preconditioning prevents reduction in brachial artery flow-mediated dilation after strenuous exercise
    Bailey, Tom G.
    Birk, Gurpreet K.
    Cable, N. Timothy
    Atkinson, Greg
    Green, Daniel J.
    Jones, Helen
    Thijssen, Dick H. J.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2012, 303 (05): : H533 - H538
  • [44] SIMULTANEOUS ULTRASOUND ASSESSMENT OF BRACHIAL ARTERY SHEAR STIMULUS AND FLOW-MEDIATED DILATION DURING REACTIVE HYPEREMIA
    Tortoli, Piero
    Palombo, Carlo
    Ghiadoni, Lorenzo
    Bini, Giacomo
    Francalanci, Lorenzo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (10) : 1561 - 1570
  • [45] Flow-mediated dilation and cardiovascular disease
    McCully, Kevin K.
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (12) : 1957 - 1958
  • [46] Ultrasound Assessment of Flow-Mediated Dilation
    Harris, Ryan A.
    Nishiyama, Steven K.
    Wray, D. Walter
    Richardson, Russell S.
    HYPERTENSION, 2010, 55 (05) : 1075 - 1085
  • [47] FLOW-MEDIATED DILATION AND INTIMA-MEDIA THICKNESS OF THE BRACHIAL AND AXILLARY ARTERIES IN INDIVIDUALS WITH AND WITHOUT INDUCIBLE AXILLARY ARTERY COMPRESSION
    Stapleton, C. H.
    Green, D. J.
    Cable, N. T.
    George, K. P.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (09) : 1443 - 1451
  • [48] Microvascular endothelial glycocalyx thickness is associated with brachial artery flow-mediated dilation
    Smilowitz, Nathaniel R.
    Luttrell-Williams, Elliot
    Golpanian, Michael
    Engel, Alexis
    Buyon, Jill P.
    Katz, Stuart D.
    Berger, Jeffrey S.
    VASCULAR MEDICINE, 2021, 26 (05) : 563 - 565
  • [49] Flow-mediated dilation and exercise blood pressure in healthy adolescents
    Lambiase, Maya J.
    Dorn, Joan
    Thurston, Rebecca C.
    Roemmich, James N.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2014, 17 (04) : 425 - 429
  • [50] Normalization of Flow-mediated Dilation to Brachial Artery Material Property: A Feasibility Study
    Sudarsan, Nimmi
    Manoj, Rahul
    Kiran, Raj, V
    Nabeel, P. M.
    Chandran, Dinu S.
    Joseph, Jayaraj
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,