Finite element analysis and design of cold-formed steel built-up closed columns with flange and web intermediate stiffeners

被引:8
|
作者
Aruna, G. [1 ]
Karthika, V [2 ]
Sukumar, S. [3 ]
机构
[1] CMR Inst Technol, Dept Civil Engn, Hyderabad, India
[2] Jay Shriram Grp Inst Tiruppur, Dept Civil Engn, Tiruppur, Tamil Nadu, India
[3] Govt Coll Engn, Dept Civil Engn, Salem, Tamil Nadu, India
关键词
built-up closed columns; cold-formed steel; direct strength method; finite element analysis; intermediate stiffeners; CHANNEL COLUMNS; BEHAVIOR; SECTION; STRENGTH; TESTS;
D O I
10.1139/cjce-2019-0063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a finite element analysis (FEA) and design of cold-formed steel built-up closed sections with intermediate stiffeners in the flange and web under axial compression. A finite element model (FEM) was developed and validated using the available experimental results. The validated FEM can be used for further parametric study on strength of built-up closed columns. The results obtained from the parametric study are compared with the current direct strength method (DSM) in the North American specification of cold-formed steel structures for those specimens that failed by only local, distortional, and flexural buckling. It is shown that the current DSM is not quite suitable for the design of cold-formed steel built-up closed columns. Therefore, the improved design equations are proposed by modifying the current design equations used in the DSM for flexural, local, and distortional buckling. The reliability of current DSM and proposed DSM was assessed by reliability analysis.
引用
收藏
页码:1175 / 1187
页数:13
相关论文
共 50 条
  • [41] Design of locally buckling cold-formed steel built-up columns formed unlipped channel sections
    Mahar, Akshay Mangal
    Jayachandran, S. Arul
    Mahendran, Mahen
    THIN-WALLED STRUCTURES, 2022, 174
  • [42] Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns
    Nie, Shaofeng
    Zhou, Tianhua
    Liao, Fangfang
    Yang, Donghua
    STRUCTURAL ENGINEERING AND MECHANICS, 2019, 70 (04) : 499 - 511
  • [43] Investigation of built-up box columns composed of four cold-formed steel channels
    Nie, Shaofeng
    Eatherton, Matthew R.
    Han, Yong
    Zhou, Tianhua
    Wu, Hanheng
    Li, Jiang
    THIN-WALLED STRUCTURES, 2022, 175
  • [44] Design of Cold-Formed Steel Back-To-Back Connected Built-up Beams
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [45] Web crippling of cold-formed steel built-up box sections
    He, Jun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 171
  • [46] Resistance of cold-formed built-up stainless steel columns - Part I: Experiment
    Dobric, Jelena
    Markovic, Zlatko
    Budevac, Dragan
    Spremic, Milan
    Fric, Nenad
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 145 : 552 - 572
  • [47] Numerical simulation and specification provisions for cruciform cold-formed steel built-up columns
    Lu, Wei-Bo
    Chen, Ming
    Shi, Yu
    Li, Bu-Shuan
    STRUCTURES, 2023, 51 : 484 - 497
  • [48] Numerical Investigation on Cold-Formed Steel Lipped Channel Columns with Intermediate Web Stiffeners
    Manikandan P.
    Arun N.
    Journal of The Institution of Engineers (India): Series A, 2016, 97 (1) : 1 - 7
  • [49] FINITE ELEMENT ANALYSIS OF AXIALLY LOADED COLD-FORMED STEEL BACK-TO-BACK CHANNEL BUILT-UP SECTIONS
    Ting, T. C. H.
    Lau, H. H.
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [50] Research on Cold-Formed Steel Stiffened-Web Built-up I-Section Columns with Complex Edge Stiffeners
    Zhuangnan Zhang
    Yudong Li
    Chungang Wang
    Yikai Hao
    Jianqiao Song
    Qinglin Guo