Determining the Potential Role of Crystalline Lens Rise in Vaulting in Posterior Chamber Phakic Collamer Lens Surgery for Correction of Myopia

被引:48
作者
Gonzalez-Lopez, Felix [1 ]
Bilbao-Calabuig, Rafael [1 ]
Mompean, Blas [2 ]
Luezas, Jorge [1 ]
Ortega-Usobiaga, Julio [1 ]
Druchkiv, Vasyl [3 ]
机构
[1] Inst Oftalmol Europeo, Dept Refract Surg, Clin Baviera, Madrid, Spain
[2] Hosp Torrevieja, Dept Ophthalmol, Alicante, Spain
[3] Inst Oftalmol Europeo, Dept Res & Dev, Clin Baviera, Madrid, Spain
关键词
WHITE-TO-WHITE; INTRAOCULAR LENSES; IMPLANTATION; DIAMETER; DEPTH;
D O I
10.3928/1081597X-20190204-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the effect of crystalline lens rise (CLR) on postoperative vault in eyes implanted with a phakic Visian Implantable Collamer Lens (ICL) (STAAR Surgical Company, Monrovia, CA) with a central port for myopic correction. METHODS: Non-invasive Fourier-domain swept-source anterior segment optical coherence tomography was used for dynamic assessment of the study eyes under changing light conditions. Phakic intraocular lens (IOL) vault, anterior chamber depth (ACD), and CLR were recorded after surgery, and intra-eye differences were analyzed under scotopic and photopic ambient light conditions. Inter-group analysis and regression analysis were performed to investigate any potential correlation between these biometric variables. RESULTS: This retrospective observational study comprised 111 eyes (65 patients) implanted with a myopic Visian ICL. The mean change in CLR from mydriasis to miosis was 59 +/- 60 mu m (P < .001). The sample was further divided into four groups according to the CLR value in miosis: CLR < 0, 0 to 200, 201 to 350, and > 350 mu m. A significant difference in central vault values was observed between the < 0 and > 350 mu m groups, the 0 to 200 and 201 to 350 mu m groups, and the 0 to 200 and > 350 mu m groups (P < .05). Eyes with a high vault value (> 750 mu m in mydriasis) had lower CLR values (P < .001) and higher ACD values (P < .001) than eyes with a low vault value (< 100 mu m in miosis). The linear correlation observed was negative between CLR and ACD, positive between postoperative vault and ACD, and negative between postoperative vault and CLR (P < .001). CONCLUSIONS: CLR significantly affected anterior chamber depth and postoperative ICL vault.
引用
收藏
页码:177 / +
页数:9
相关论文
共 16 条
  • [1] Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Lisa, Carlos
    Fernandes, Paulo
    Jorge, Jorge
    Montes Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) : 46 - 53
  • [2] Anterior segment OCT and phakic intraocular lenses:: A perspective
    Baikoff, Georges
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1827 - 1835
  • [3] Choi KH, 2007, J REFRACT SURG, V23, P362
  • [4] Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy
    Dougherty, Paul J.
    Rivera, Robert P.
    Schneider, David
    Lane, Stephen S.
    Brown, David
    Vukich, John
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) : 13 - 18
  • [5] A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: correlation between ocular biometric parameters
    Ghoreishi, Mohammad
    Abdi-Shahshahani, Mehdi
    Peyman, Alireza
    Pourazizi, Mohsen
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (03) : 661 - 666
  • [6] Dynamic Assessment of Light-Induced Vaulting Changes of Implantable Collamer Lens With Central Port by Swept-Source OCT: Pilot Study
    Gonzalez-Lopez, Felix
    Mompean, Blas
    Bilbao-Calabuig, Rafael
    Vila-Arteaga, Jorge
    Beltran, Jaime
    Baviera, Julio
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [7] Intraocular pressure during the early postoperative period after 100 consecutive implantations of posterior chamber phakic intraocular lenses with a central hole
    Gonzalez-Lopez, Felix
    Bilbao-Calabuig, Rafael
    Mompean, Blas
    de Rojas, Victoria
    Luezas, Jorge
    Reza Djodeyre, Mohammad
    Beltran, Jaime
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12) : 1859 - 1863
  • [8] Optimization of an Implantable Collamer Lens Sizing Method Using High-Frequency Ultrasound Biomicroscopy
    Kojima, Takashi
    Yokoyama, Sho
    Ito, Mayuka
    Horai, Rie
    Hara, Shuya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (04) : 632 - 637
  • [9] Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes
    Lee, Hun
    Kang, David Sung Yong
    Choi, Jin Young
    Ha, Byoung Jin
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    [J]. BMC OPHTHALMOLOGY, 2018, 18
  • [10] Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomography
    Malyugin, Boris E.
    Shpak, Alexander A.
    Pokrovskiy, Dmitry F.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08) : 1616 - 1622