Ion-pair reversed-phase chromatography of short double-stranded deoxyribonucleic acid in silicon micro-pillar array columns: Retention model and applications

被引:16
|
作者
Zhang, Lei [1 ,2 ]
Majeed, Bivragh [1 ]
Lagae, Liesbet [1 ]
Peumans, Peter [1 ]
Van Hoof, Chris [1 ,2 ]
De Malsche, Wim [3 ]
机构
[1] IMEC, Louvain, Belgium
[2] Katholieke Univ Leuven, Dept Elect Engn, Louvain, Belgium
[3] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
DNA chromatography; Ion-pair RP-HPLC; Retention prediction; Silicon micro-pillar array column; Lab on a chip; PERFORMANCE LIQUID-CHROMATOGRAPHY; GRADIENT-ELUTION; DNA FRAGMENTS; LARGE BIOMOLECULES; SEPARATION; ELECTROPHORESIS; SELECTIVITY; BEHAVIOR; PEPTIDE;
D O I
10.1016/j.chroma.2013.04.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation of double-stranded (ds) DNAs is important in numerous biochemical analyses relevant for clinical applications. A widely used separation technique is high performance liquid chromatography (HPLC), in the variant of ion-pair reversed-phase (IP-RP) chromatography. HPLC can be miniaturized by means of silicon micro-pillar array columns leading to on-chip fast and high resolution dsDNA separation with limited sample quantity. However, theoretical studies of retentive behavior of dsDNA in miniaturized chromatographic columns are hardly available, despite their enormous practical relevance. This paper established a new retention model to describe the size dependent separation of dsDNAs for any characteristic of the linear mobile phase gradient, in analogy to the model used to describe the retention of polymer chains with repeating units in RP HPLC. The model agrees with a large amount of dsDNA retention data, measured using DNA molecules in the size range of 10-400 base pairs in columns with different lengths (2 and 40 cm) and different micro-pillar sizes (2 and 2.5 mu m in diameter), in various mobile phase gradients. The model is particularly useful in practice, since it requires no numerical solutions and the column-specific fitting parameters (4 or 5) can be determined in a limited number of separation runs. As examples of its applications, the model has been used for the optimization of dsDNA step-gradient separations (5 dsDNAs separated within 8 min) and for the determination of the size of dsDNA fragment (with uncertainty of about 2%). These applications are especially relevant for on-chip DNA analysis devices. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 11 条
  • [11] Quantitative structure-retention relationship for reliable metabolite identification and quantification in metabolomics using ion-pair reversed-phase chromatography coupled with tandem mass spectrometry
    Hu, Qingyu
    Sun, Yuting
    Yuan, Peihong
    Lei, Hehua
    Zhong, Huiqin
    Wang, Yulan
    Tang, Huiru
    TALANTA, 2022, 238