4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography

被引:78
作者
Wildes, Douglas [1 ]
Lee, Warren [1 ]
Haider, Bruno [1 ,2 ]
Cogan, Scott [1 ,3 ]
Sundaresan, Krishnakumar [1 ]
Mills, David M. [1 ]
Yetter, Christopher [1 ]
Hart, Patrick H. [1 ,4 ]
Haun, Christopher R. [1 ]
Concepcion, Mikael [5 ,6 ]
Kirkhorn, Johan [7 ]
Bitoun, Marc [8 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Phoenix, AZ 85040 USA
[3] Michigan State Univ, E Lansing, MI 48824 USA
[4] GE Fuel Cells, Malta, NY 12020 USA
[5] Thomas Med Prod, Malvern, PA 19355 USA
[6] Merit Med Syst Inc, Malvern, PA 19355 USA
[7] GE Vingmed Ultrasound, N-3191 Horten, Norway
[8] Shifamed LLC, Campbell, CA 95008 USA
关键词
Application-specific integrated circuit (ASIC); catheters; four-dimensional (4-D); intracardiac; three-dimensional (3-D); two-dimensional (2-D) array; ultrasonic transducer arrays; ATRIAL SEPTAL-DEFECT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DEVICE CLOSURE; INITIAL-EXPERIENCE; MATRIX TRANSDUCER; ULTRASOUND; ABLATION; SYSTEM; INTERVENTIONS; FEASIBILITY;
D O I
10.1109/TUFFC.2016.2615602
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a 2.5x6.6 mm(2) 2-D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm(2) area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 degrees x 60 degrees x 8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.
引用
收藏
页码:2159 / 2173
页数:15
相关论文
共 54 条
[11]   Volumetric Real-Time Imaging Using a CMUT Ring Array [J].
Choe, Jung Woo ;
Oralkan, Oemer ;
Nikoozadeh, Amin ;
Gencel, Mustafa ;
Stephens, Douglas N. ;
O'Donnell, Matthew ;
Sahn, David J. ;
Khuri-Yakub, Butrus T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (06) :1201-1211
[12]   In Vivo Real-Time 3-D Intracardiac Echo Using PMUT Arrays [J].
Dausch, David E. ;
Gilchrist, Kristin H. ;
Carlson, James B. ;
Hall, Stephen D. ;
Castellucci, John B. ;
von Ramm, Olaf T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (10) :1754-1764
[13]   3D TEE During Catheter-Based Interventions [J].
Faletra, Francesco Fulvio ;
Pedrazzini, Giovanni ;
Pasotti, Elena ;
Muzzarelli, Stefano ;
Dequarti, Maria Cristina ;
Murzilli, Romina ;
Schlossbauer, Susanne Anna ;
Slater, Iveta Petrova ;
Moccetti, Tiziano .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) :292-308
[14]   Transesophageal Echocardiography in Critically III Acute Postoperative Infants: Comparison of AcuNav Intracardiac Echocardiographic and microTEE Miniaturized Transducers [J].
Ferns, Sunita ;
Komarlu, Rukmini ;
Van Bergen, Andrew ;
Multani, Kanwar ;
Cui, Vivian Wei ;
Roberson, David A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (08) :874-881
[15]  
Freeman S., 2012, CISC VIS NETW IND GL
[16]  
Gelly J.-F., 2009, U.S. Patent, Patent No. [7621028B2, 7621028]
[17]  
Gonzalez I., 2012, ARTRIAL SEPTAL DEFEC, P99
[18]   Transnasal Transesophageal Echocardiography: A New Approach for the PFO Occlusion in Awake Patients [J].
Greco, Cesare ;
Chiavari, Piero A. ;
Campolongo, Giuseppe ;
Mariani, Simona ;
Messa, Fortunato ;
Tallarico, Demetrio ;
Schiariti, Michele ;
Gonnella, Carlo ;
Gaudio, Carlo .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) :538-541
[19]   Single-Chip CMUT-on-CMOS Front-End System for Real-Time Volumetric IVUS and ICE Imaging [J].
Gurun, Gokce ;
Tekes, Coskun ;
Zahorian, Jaime ;
Xu, Toby ;
Satir, Sarp ;
Karaman, Mustafa ;
Hasler, Jennifer ;
Degertekin, F. Levent .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (02) :239-250
[20]   Intracardiac Echocardiography During Interventional and Electrophysiological Cardiac Catheterization [J].
Hijazi, Ziyad M. ;
Shivkumar, Kalyanam ;
Sahn, David J. .
CIRCULATION, 2009, 119 (04) :587-U180