4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography

被引:78
作者
Wildes, Douglas [1 ]
Lee, Warren [1 ]
Haider, Bruno [1 ,2 ]
Cogan, Scott [1 ,3 ]
Sundaresan, Krishnakumar [1 ]
Mills, David M. [1 ]
Yetter, Christopher [1 ]
Hart, Patrick H. [1 ,4 ]
Haun, Christopher R. [1 ]
Concepcion, Mikael [5 ,6 ]
Kirkhorn, Johan [7 ]
Bitoun, Marc [8 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Phoenix, AZ 85040 USA
[3] Michigan State Univ, E Lansing, MI 48824 USA
[4] GE Fuel Cells, Malta, NY 12020 USA
[5] Thomas Med Prod, Malvern, PA 19355 USA
[6] Merit Med Syst Inc, Malvern, PA 19355 USA
[7] GE Vingmed Ultrasound, N-3191 Horten, Norway
[8] Shifamed LLC, Campbell, CA 95008 USA
关键词
Application-specific integrated circuit (ASIC); catheters; four-dimensional (4-D); intracardiac; three-dimensional (3-D); two-dimensional (2-D) array; ultrasonic transducer arrays; ATRIAL SEPTAL-DEFECT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DEVICE CLOSURE; INITIAL-EXPERIENCE; MATRIX TRANSDUCER; ULTRASOUND; ABLATION; SYSTEM; INTERVENTIONS; FEASIBILITY;
D O I
10.1109/TUFFC.2016.2615602
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a 2.5x6.6 mm(2) 2-D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm(2) area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 degrees x 60 degrees x 8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.
引用
收藏
页码:2159 / 2173
页数:15
相关论文
共 54 条
[1]   Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults [J].
Alboliras, ET ;
Hijazi, ZM .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (05) :690-692
[2]   Comparison of intracardiac echocardiography and transesophageal echocardiography for imaging of the right and Left atrial appendages [J].
Anter, Elad ;
Silverstein, Joshua ;
Tschabrunn, Cory M. ;
Shvilkin, Alexei ;
Haffajee, Charles I. ;
Zimetbaum, Peter J. ;
Buxton, Alfred E. ;
Josephson, Mark E. ;
Gelfand, Eli ;
Manning, Warren J. .
HEART RHYTHM, 2014, 11 (11) :1890-1897
[3]   Intracardiac echocardiography in complex cardiac catheter ablation procedures [J].
Banchs, Javier E. ;
Patel, Parag ;
Naccarelli, Gerald V. ;
Gonzalez, Mario D. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 28 (03) :167-184
[4]   Intracardiac Echocardiography for Detection of Thrombus in the Left Atrial Appendage Comparison With Transesophageal Echocardiography in Patients Undergoing Ablation for Atrial Fibrillation: The Action-Ice I Study [J].
Baran, Jakub ;
Stec, Sebastian ;
Pilichowska-Paszkiet, Ewa ;
Zaborska, Beata ;
Sikora-Frac, Malgorzata ;
Krynski, Tomasz ;
Michalowska, Ilona ;
Lopatka, Rafal ;
Kulakowski, Piotr .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) :1074-1081
[5]   Intraprocedural guidance: which imaging technique ranks highest and which one is complementary for closing paravalvular leaks? [J].
Bartel, Thomas ;
Mueller, Silvana .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (04) :277-278
[6]   Why is intracardiac echocardiography helpful? Benefits, costs, and how to learn [J].
Bartel, Thomas ;
Mueller, Silvana ;
Biviano, Angelo ;
Hahn, Rebecca T. .
EUROPEAN HEART JOURNAL, 2014, 35 (02) :69-+
[7]   Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement [J].
Bartel, Thomas ;
Bonaros, Nikolaos ;
Mueller, Ludwig ;
Friedrich, Guy ;
Grimm, Michael ;
Velik-Salchner, Corinna ;
Feuchtner, Gudrun ;
Pedross, Florian ;
Mueller, Silvana .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (09) :966-975
[8]  
Blaak S., 2009, 2009 IEEE International Ultrasonics Symposium, P1338, DOI 10.1109/ULTSYM.2009.5441534
[9]   Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect [J].
Boccalandro, F ;
Baptista, E ;
Muench, A ;
Carter, C ;
Smalling, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04) :437-440
[10]   A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography [J].
Chen, Chao ;
Raghunathan, Shreyas B. ;
Yu, Zili ;
Shabanimotlagh, Maysam ;
Chen, Zhao ;
Chang, Zu-yao ;
Blaak, Sandra ;
Prins, Christian ;
Ponte, Jacco ;
Noothout, Emile ;
Vos, Hendrik J. ;
Bosch, Johan G. ;
Verweij, Martin D. ;
de Jong, Nico ;
Pertijs, Michiel A. P. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) :47-59