The great myth of office blood pressure measurement

被引:88
作者
Myers, Martin G. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Div Cardiol, Schulich Heart Program, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
关键词
automated sphygmomanometers; blood pressure measurement; EDUCATION-PROGRAM RECOMMENDATIONS; HYPERTENSION; ALGORITHM; RELIABILITY; VALIDATION; DIAGNOSIS; IMPACT; SELF;
D O I
10.1097/HJH.0b013e3283577b05
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Clinical practice guidelines have traditionally recommended manual blood pressure (BP) measurement in the office setting as the standard method for diagnosing hypertension. In reality, manual BP in routine clinical practice is relatively inaccurate, over-diagnoses hypertension by provoking office-induced increases in BP and correlates poorly with both the awake ambulatory BP and target organ damage. The most recent guidelines recommend 24-h ambulatory BP and home BP for diagnosing hypertension. The advent of automated office BP (AOBP) represents a third alternative to conventional manual BP measurement, one that maintains the role of office BP readings in the diagnosis and management of hypertension. AOBP has three basic principles: multiple readings taken using a fully automated sphygmomanometer with the patient resting quietly alone. AOBP eliminates office-induced hypertension such that the cut-point for a normal AOBP is the same as for the awake ambulatory BP and home BP. As compared to routine manual office BP, AOBP provides more accurate BP readings, is more consistent during repeated office visits and in different settings and correlates better with both the awake ambulatory BP and target organ damage. The advantages of AOBP over manual BP measurement support its use in routine clinical practice.
引用
收藏
页码:1894 / 1898
页数:5
相关论文
共 41 条
  • [1] Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index
    Andreadis, Emmanuel A.
    Agaliotis, Gerasimos D.
    Angelopoulos, Epameinondas T.
    Tsakanikas, Athanasios P.
    Chaveles, Loannis A.
    Mousoulis, George P.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) : 661 - 666
  • [2] The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension
    Beckett L.
    Godwin M.
    [J]. BMC Cardiovascular Disorders, 5 (1)
  • [3] Is resistant hypertension really resistant?
    Brown, MA
    Buddle, ML
    Martin, A
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2001, 14 (12) : 1263 - 1269
  • [4] Blood pressure rising: differences between current clinical and recommended measurement techniques
    Burgess, Steven E.
    MacLaughlin, Eric J.
    Smith, Paul A.
    Salcido, Armando
    Benton, Timothy J.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2011, 5 (06) : 484 - 488
  • [5] Automated oscillometric blood pressure versus auscultatory blood pressure as a predictor of carotid intima-medial thickness in male firefighters
    Campbell, N. R. C.
    McKay, D. W.
    Conradson, H.
    Lonn, E.
    Title, L. M.
    Anderson, T.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2007, 21 (07) : 588 - 590
  • [6] Prevention of cardiovascular events with an antihypertensive regimen of amlodipine adding perindopril as required versus atenolol adding bendroflumethiazide as required, in the Anglo-Scandinavian Cardiac Outcomes Trial-Blood Pressure Lowering Arm (ASCOT-BPLA):: a multicentre randomised controlled trial
    Dahlöf, B
    Sever, PS
    Poulter, NR
    Wedel, H
    Beevers, DG
    Caulfield, M
    Collins, R
    Kjeldsen, SE
    Kristinsson, A
    McInnes, GT
    Mehlsen, J
    Nieminen, M
    O'Brien, E
    Östergren, J
    [J]. LANCET, 2005, 366 (9489) : 895 - 906
  • [7] Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring
    Godwin, Marshall
    Birtwhistle, Richard
    Delva, Dianne
    Lam, Miu
    Casson, Ian
    MacDonald, Susan
    Seguin, Rachelle
    [J]. FAMILY PRACTICE, 2011, 28 (01) : 110 - 117
  • [8] METERED-DOSE INHALER USAGE IN SUBJECTS WITH ASTHMA - COMPARISON OF NEBULIZER CHRONOLOG AND DAILY DIARY RECORDINGS
    GONG, H
    SIMMONS, MS
    CLARK, VA
    TASHKIN, DP
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1988, 82 (01) : 5 - 10
  • [9] Clinical decision-making in hypertension using an automated (BpTRU™) measurement device
    Graves, JW
    Nash, C
    Burger, K
    Bailey, K
    Sheps, SG
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2003, 17 (12) : 823 - 827
  • [10] Where should automated blood pressure measurements be taken? Pilot RCT of BpTRU measurements taken in private or nonprivate areas of a primary care office
    Greiver, Michelle
    White, David
    Kaplan, David M.
    Katz, Kevin
    Moineddin, Rahim
    Dolabchian, Edita
    [J]. BLOOD PRESSURE MONITORING, 2012, 17 (03) : 137 - 138