Changes in Anterior and Posterior Corneal Parameters in Patients with Keratoconus After Intrastromal Corneal-ring Segment Implantation

被引:16
|
作者
Rho, Chang Rae [1 ]
Na, Kyung-Sun [2 ]
Yoo, Young Sik [2 ]
Pandey, Chitra [2 ]
Park, Chang Won [2 ]
Joo, Choun-Ki [2 ]
机构
[1] Catholic Univ Korea, Daejeon St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137040, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137040, South Korea
关键词
Anterior chamber depth; corneal topography; intrastromal ring segment implantation; keratoconus; keratometry; TERM-FOLLOW-UP; INTACS; MANAGEMENT; MODERATE; OUTCOMES;
D O I
10.3109/02713683.2013.788723
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare changes in the anterior and the posterior corneal parameters and the anterior chamber depth (ACD) measured by a rotating Scheimpflug camera and scanning-slit topography before and after intrastromal corneal ring segment (ICRS) implantation. Methods: Twenty-five eyes of 21 keratoconus patients who had Intacs (Addition Technology, Sunnyvale, CA) ICRS implantation were included. The anterior segment parameters of the participants were measured before and 3 months after Intacs ICRS implantation with a rotating Scheimpflug camera and scanning-slit topography. Outcome measures included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction and corneal topography. Results: The UDVA improved in 21 eyes (84%) and CDVA in 18 eyes (72%). The anterior average keratometry decreased from 51.80 D preoperatively to 49.59 D postoperatively (p<0.001) using the rotating Scheimpflug camera and Sim K decreased from 51.21 to 47.44 D using the scanning-slit topography. The posterior average keratometry decreased from -8.03 D preoperatively to -8.42 D postoperatively (p<0.001) using the rotating Scheimpflug camera. ACD decreased from 3.44 to 3.32mm (p<0.001) and from 3.28 to 3.19mm (p<0.001) using the rotating Scheimpflug camera and scanning-slit topography, respectively. Conclusions: The implantation of Intacs segments induced corneal flattening of the anterior surface and corneal steepening of the posterior surface. Both anterior corneal flattening and posterior corneal steepening contributed to the decrease in the keratometric power.
引用
收藏
页码:843 / 850
页数:8
相关论文
共 50 条
  • [41] Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus
    Carballo, Jesus
    Cinta Puell, Maria
    Cuina, Ricardo
    Maria Vazquez, Jose
    Benitez-del-Castillo, Jose M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 393 - 402
  • [42] Refractive and biometric changes after implantation of the intrastromal corneal ring
    Twa, MD
    Schanzlin, DJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S105 - S105
  • [43] Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus
    Beniz, Luiz Arthur F.
    Queiroz, Gustavo H.
    Queiroz, Carlos F.
    Lopes, Wanessa L.
    Moraes, Leiser F.
    Beniz, Jose
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (01) : 30 - 32
  • [44] Tonometry after Intrastromal Corneal Ring Segments for Keratoconus
    Arribas-Pardo, Paula
    Mendez-Hernandez, Carmen
    Cuina-Sardina, Ricardo
    Manuel Benitez-del-Castillo, Jose
    Garcia-Feijoo, Julian
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (10) : 986 - 992
  • [45] Polar Value Analysis of Corneal Astigmatism in Intrastromal Corneal Ring Segment Implantation
    Rho, Chang Rae
    Kim, Min-Ji
    Joo, Choun-Ki
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [46] Efficacy of single or paired intrastromal corneal ring segment implantation combined with collagen crosslinking in keratoconus
    Yeung, Sonia N.
    Ku, Judy Y. F.
    Lichtinger, Alejandro
    Low, Stephanie A. W.
    Kim, Peter
    Rootman, David S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (08): : 1146 - 1151
  • [47] Intrastromal corneal ring segment implantation in paracentral keratoconus with perpendicular topographic astigmatism and comatic axis
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Alfonso-Bartolozzi, Belen
    Madrid-Costa, David
    Alfonso, Jose F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1540 - 1545
  • [48] Corneal Cross-linking Combined With Intrastromal Corneal Ring Implantation for Progressive Keratoconus
    Gatzioufas, Zisis
    CORNEA, 2013, 32 (03) : 381 - 382
  • [49] Keratoconus progression after intrastromal corneal ring segment implantation in young patients: Five-year follow-up
    Vega-Estrada, Alfredo
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1145 - 1152
  • [50] The variability of corneal and anterior segment parameters in keratoconus
    Mas-Aixala, Enric
    Gispets, Joan
    Lupon, Nuria
    Cardona, Genis
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (06): : 466 - 470