Changes in Anterior and Posterior Corneal Parameters in Patients with Keratoconus After Intrastromal Corneal-ring Segment Implantation

被引:16
|
作者
Rho, Chang Rae [1 ]
Na, Kyung-Sun [2 ]
Yoo, Young Sik [2 ]
Pandey, Chitra [2 ]
Park, Chang Won [2 ]
Joo, Choun-Ki [2 ]
机构
[1] Catholic Univ Korea, Daejeon St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137040, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul 137040, South Korea
关键词
Anterior chamber depth; corneal topography; intrastromal ring segment implantation; keratoconus; keratometry; TERM-FOLLOW-UP; INTACS; MANAGEMENT; MODERATE; OUTCOMES;
D O I
10.3109/02713683.2013.788723
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare changes in the anterior and the posterior corneal parameters and the anterior chamber depth (ACD) measured by a rotating Scheimpflug camera and scanning-slit topography before and after intrastromal corneal ring segment (ICRS) implantation. Methods: Twenty-five eyes of 21 keratoconus patients who had Intacs (Addition Technology, Sunnyvale, CA) ICRS implantation were included. The anterior segment parameters of the participants were measured before and 3 months after Intacs ICRS implantation with a rotating Scheimpflug camera and scanning-slit topography. Outcome measures included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction and corneal topography. Results: The UDVA improved in 21 eyes (84%) and CDVA in 18 eyes (72%). The anterior average keratometry decreased from 51.80 D preoperatively to 49.59 D postoperatively (p<0.001) using the rotating Scheimpflug camera and Sim K decreased from 51.21 to 47.44 D using the scanning-slit topography. The posterior average keratometry decreased from -8.03 D preoperatively to -8.42 D postoperatively (p<0.001) using the rotating Scheimpflug camera. ACD decreased from 3.44 to 3.32mm (p<0.001) and from 3.28 to 3.19mm (p<0.001) using the rotating Scheimpflug camera and scanning-slit topography, respectively. Conclusions: The implantation of Intacs segments induced corneal flattening of the anterior surface and corneal steepening of the posterior surface. Both anterior corneal flattening and posterior corneal steepening contributed to the decrease in the keratometric power.
引用
收藏
页码:843 / 850
页数:8
相关论文
共 50 条
  • [31] Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
    Hamdi, Islam M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1125 - 1132
  • [32] Successful Management of Corneal Hydrops and Intrastromal Corneal Ring Segment (ICRS) Migration Following ICRS Implantation for Keratoconus
    Ontiveros-Holguin, Alejandro
    Pacheco-Padron, Jorge
    AMERICAN JOURNAL OF CASE REPORTS, 2022, 23
  • [33] Double intrastromal corneal ring segment implantation: a new approach for improved clinical outcomes in keratoconus patients
    Coscarelli, Sandro
    Sieiro, Reinaldo de Oliveira
    Fernandes, Victoria Moreira
    Coscarelli, Sandro P.
    Torquetti, Leonardo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (11) : 2023 - 2030
  • [34] Anterior and Posterior Corneal Changes after Crosslinking for Keratoconus
    Steinberg, Johannes
    Ahmadiyar, Mariam
    Rost, Anika
    Frings, Andreas
    Filev, Filip
    Katz, Toam
    Linke, Stephan J.
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : 178 - 186
  • [35] Long term outcome of Intrastromal corneal ring segment in keratoconus
    Kang, M. J.
    Lee, J. H.
    Choi, M. H.
    Joo, C. K.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [36] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Souza Stival, Larissa Rossana
    do Amaral Nassaralla, Belquiz R.
    Falleiro Chaves de Figueiredo, Marisa Novaes
    Bicalho, Frederico
    Nassaralla Junior, Joao Jorge
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (04) : 212 - 215
  • [37] INTRASTROMAL CORNEAL RING SEGMENT IMPLANTATION FOR ECTASIA AFTER REFRACTIVE SURGERY
    Stival, Larissa Rossana
    Nassaralla, Belquiz A.
    Figueiredo, Marisa
    Bicalho, Frederico
    Nassaralla, Joao J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [38] Tomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus
    Lyra, Joao Marcelo
    Lyra, Daniela
    Ribeiro, Guilherme
    Torquetti, Leonardo
    Ferrara, Paulo
    Machado, Aydano
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (02) : 110 - +
  • [39] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Torquetti, Leonardo
    Ferrara, Paulo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 986 - 990
  • [40] Intrastromal Corneal Ring Segment Explantation in Patients With Keratoconus: Causes, Technique, and Outcomes
    Chhadva, Priyanka
    Yesilirmak, Nilufer
    Cabot, Florence
    Yoo, Sonia H.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (06) : 392 - U105