A new ventricular fibrillation detection algorithm for automated external defibrillators

被引:0
|
作者
Amann, A [1 ]
Tratnig, R [1 ]
Unterkofler, K [1 ]
机构
[1] Innsbruck Med Univ, Dept Anesthesia & Gen Intens Care, A-6020 Innsbruck, Austria
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A pivotal component in AEDs is the detection of ventricular fibrillation by means of appropriate detection algorithms. In scientific literature there exists a wide variety of methods and ideas for handling this task. These algorithms should have a high detection quality, be easily implementable, and work in real time in an AED. Testing of these algorithms should be done by using a large amount of annotated data under equal conditions. For our investigation we simulated a continuous analysis by selecting the data in steps of one second without any preselection. We used the BIH-MIT arrhythmia, the CU, and the AHA database. For a new ventricular fibrillation detection algorithm we calculated the sensitivity, specificity, and the area under its receiver operating characteristic curve (ROC) and compared these values with the results from an earlier investigation of several different ventricular fibrillation detection algorithms. This new algorithm is based on the Hilbert transform and outperforms all other investigated algorithms.
引用
收藏
页码:559 / 562
页数:4
相关论文
共 50 条
  • [1] Reliability of old and new ventricular fibrillation detection algorithms for automated external defibrillators
    Anton Amann
    Robert Tratnig
    Karl Unterkofler
    BioMedical Engineering OnLine, 4
  • [2] Reliability of old and new ventricular fibrillation detection algorithms for automated external defibrillators
    Amann, Anton
    Tratnig, Robert
    Unterkofler, Karl
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [3] Ventricular fibrillation and the use of automated external defibrillators on children
    Markenson, David
    Pyles, Lee
    Neish, Steve
    PEDIATRICS, 2007, 120 (05) : E1368 - E1379
  • [4] Analyze Whilst Compressing algorithm for detection of ventricular fibrillation during CPR: A comparative performance evaluation for automated external defibrillators
    Didon, Jean-Philippe
    Menetre, Sarah
    Jekova, Irena
    Stoyanov, Todor
    Krasteva, Vessela
    RESUSCITATION, 2021, 160 : 94 - 102
  • [5] Accurate recognition and effective treatment of ventricular fibrillation by automated external defibrillators in adolescents
    Atkins, DL
    Hartley, LL
    York, DK
    PEDIATRICS, 1998, 101 (03) : 393 - 397
  • [6] Inappropriate analyses of automated external Defibrillators used during in-hospital ventricular fibrillation
    Yamamoto, Takeshi
    Takayama, Morimasa
    Sato, Naoki
    Yodogawa, Kenji
    Iwasaki, Yu-Ki
    Kato, Koji
    Yoshida, Asuka
    Yoshida, Ryusuke
    Tanaka, Keiji
    Takano, Teruo
    Mizuno, Kyoichi
    CIRCULATION JOURNAL, 2008, 72 (04) : 679 - 681
  • [7] Development of Ventricular Fibrillation Diagnosis Method Based on Neuro-fuzzy Systems for Automated External Defibrillators
    Sang-Hong Lee
    International Journal of Fuzzy Systems, 2017, 19 : 440 - 451
  • [8] Development of Ventricular Fibrillation Diagnosis Method Based on Neuro-fuzzy Systems for Automated External Defibrillators
    Lee, Sang-Hong
    INTERNATIONAL JOURNAL OF FUZZY SYSTEMS, 2017, 19 (02) : 440 - 451
  • [9] Automated external defibrillators
    Jordan, Dan
    Biomedical Instrumentation and Technology, 2003, 37 (01): : 55 - 59
  • [10] Automated external defibrillators
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2006, 48 (1241-2): : 71 - 72