SiPM-based dual-ended-readout DOI-TOF PET module based on mean-time method

被引:15
|
作者
Han, Y. B. [1 ]
Kang, H. G. [1 ,2 ]
Song, S. H. [1 ]
Ko, G. B. [3 ]
Lee, J. S. [3 ]
Hong, S. J. [1 ,4 ]
机构
[1] Eulji Univ, Dept Senior Healthcare, Grad Sch, 771 Gyeryong Ro, Daejeon 34824, South Korea
[2] Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, 101 Daehak Ro, Seoul 03080, South Korea
[4] Eulji Univ, Dept Radiol Sci, 553 Sanseong Daero, Seongnam Si 13135, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Scintigraphy and whole-body imaging; OF-FLIGHT; DETECTOR; DEPTH; PERFORMANCE; RESOLUTION;
D O I
10.1088/1748-0221/14/02/P02023
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Positron emission tomography (PET) with high resolution and high sensitivity is desirable for detecting cancers and neurological diseases. In this work, a depth-of-interaction (DOI)-time-of-flight (TOF) PET has been attempted to achieve both high spatial and high timing resolution. Dual-ended readout is a simple technique that can provide excellent timing and DOI resolutions and consistent signal arrival times, regardless of the DOI position along the scintillation crystal, as a mean-time method is used. A dual-ended readout DOI-TOF PET module consisting of a 6 x 6 array of 2 x 2 x 20 mm(3) saw-cut cerium-doped lutetium-yttrium oxyorthosilicate (LYSO) crystals is constructed. Both ends of the LYSO crystal array are optically coupled to a multi-pixel photon counter (MPPC) with 4 x 4 channels. The sixteen MPPC outputs are reduced to four position signals using a charge division circuit (CDC) board, and the timing signal is extracted from the common cathode of the MPPC. The four position signals from the MPPC are digitized by a DRS4-based high-speed waveform digitizer with a sampling rate of 5 GSa/s. A Na-22 source is placed in front of a reference detector and at the side of the dual-ended readout DOI-TOF PET module in five steps of 2 mm, 6 mm, 10 mm, 14 mm, and 18 mm to measure the DOI, coincidence timing resolutions (CTRs), and mean-times. The full-width-half-maximums (FWHMs) of DOI resolutions and CTRs varied from 3.0 mm to 3.8 mm, with an average of 3.5 mm, and from 333 ps to 367 ps, with an average of 349 ps, respectively. The average of the slopes of the mean-time versus DOI position, for the 36 crystals, was -0.60 +/- 1.68 ps/nm, which was consistent with the null value. The dual-ended readout DOI-TOF PET module based on the mean-time method produced both good DOI and CTRs, and consistent signal arrival times. The found solution would be the most advantageous in the small aperture PET systems, such as those for brain and breast imaging.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Development of a SiPM Based MR-Compatible DOI-TOF-PET Detector
    Furumiya, Tetsuo
    Tsuda, Tomoaki
    Tonami, Hiromichi
    Satoh, Masanobu
    Nakazawa, Masayuki
    Ohi, Junichi
    Kitamura, Keishi
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [22] Towards 1mm PET Resolution Using DOI Modules Based on Dual-Sided SiPM Readout
    Delfino, Evan P.
    Majewski, Stan
    Raylman, Raymond R.
    Stolin, Alexander
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3442 - 3449
  • [23] A fast preamplifier concept for SiPM-based time-of-flight PET detectors
    Huizenga, J.
    Seifert, S.
    Schreuder, F.
    van Dam, H. T.
    Dendooven, P.
    Lohner, H.
    Vinke, R.
    Schaart, D. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 379 - 384
  • [24] Time-Based Readout of a Silicon Photomultiplier (SiPM) for Time of Flight Positron Emission Tomography (TOF-PET)
    Powolny, F.
    Auffray, E.
    Brunner, S. E.
    Garutti, E.
    Goettlich, M.
    Hillemanns, H.
    Jarron, P.
    Lecoq, P.
    Meyer, T.
    Schultz-Coulon, H. C.
    Shen, W.
    Williams, M. C. S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 597 - 604
  • [25] A dual-ended readout PET detector module based on GAPDs with large-area microcells
    Kang, Jihoon
    Choi, Yong
    Hong, Key Jo
    Hu, Wei
    Jung, Jin Ho
    Huh, Yoonsuk
    Lim, Hyun Keong
    Kim, Byung-Tae
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [26] Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT
    Wagatsuma, Kei
    Miwa, Kenta
    Sakata, Muneyuki
    Oda, Keiichi
    Ono, Haruka
    Kameyama, Masashi
    Toyohara, Jun
    Ishii, Kenji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 203 - 210
  • [27] Performance Characterization of an SiPM-based Time-of-Flight Canon PET/CT Scanner
    Li, Xiaoli
    Qi, Wenyuan
    Miyahara, Masaki
    Kolthammer, Jeff
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [28] New developments at INFN-LNS on TOF-DOI PET based on SiPM detectors
    Cosentino, L.
    Cusanno, F.
    De Leo, R.
    Di Venti, G.
    Finocchiaro, P.
    Garibaldi, F.
    Loddo, F.
    Meddi, F.
    Musico, P.
    Pappalardo, A.
    Perrino, R.
    Ranieri, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 10 - 12
  • [29] Evaluation of dual-ended readout GAGG-based DOI-PET detectors with different surface treatments
    Choghadi, M. Amin
    Huang, Sheng C.
    Shimazoe, Kenji
    Takahashi, Hiroyuki
    MEDICAL PHYSICS, 2021, 48 (07) : 3470 - 3478
  • [30] Dual-ended Readout PET Detector Module Based on GAPD Having Large-area Microcells
    Kang, Jihoon
    Choi, Yong
    Hong, Key Jo
    Hu, Wei
    Huh, Yoonsuk
    Lim, Hyun Keong
    Kim, Byung-Tae
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3205 - 3209