SiPM-based dual-ended-readout DOI-TOF PET module based on mean-time method

被引:17
作者
Han, Y. B. [1 ]
Kang, H. G. [1 ,2 ]
Song, S. H. [1 ]
Ko, G. B. [3 ]
Lee, J. S. [3 ]
Hong, S. J. [1 ,4 ]
机构
[1] Eulji Univ, Dept Senior Healthcare, Grad Sch, 771 Gyeryong Ro, Daejeon 34824, South Korea
[2] Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, 101 Daehak Ro, Seoul 03080, South Korea
[4] Eulji Univ, Dept Radiol Sci, 553 Sanseong Daero, Seongnam Si 13135, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Scintigraphy and whole-body imaging; OF-FLIGHT; DETECTOR; DEPTH; PERFORMANCE; RESOLUTION;
D O I
10.1088/1748-0221/14/02/P02023
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Positron emission tomography (PET) with high resolution and high sensitivity is desirable for detecting cancers and neurological diseases. In this work, a depth-of-interaction (DOI)-time-of-flight (TOF) PET has been attempted to achieve both high spatial and high timing resolution. Dual-ended readout is a simple technique that can provide excellent timing and DOI resolutions and consistent signal arrival times, regardless of the DOI position along the scintillation crystal, as a mean-time method is used. A dual-ended readout DOI-TOF PET module consisting of a 6 x 6 array of 2 x 2 x 20 mm(3) saw-cut cerium-doped lutetium-yttrium oxyorthosilicate (LYSO) crystals is constructed. Both ends of the LYSO crystal array are optically coupled to a multi-pixel photon counter (MPPC) with 4 x 4 channels. The sixteen MPPC outputs are reduced to four position signals using a charge division circuit (CDC) board, and the timing signal is extracted from the common cathode of the MPPC. The four position signals from the MPPC are digitized by a DRS4-based high-speed waveform digitizer with a sampling rate of 5 GSa/s. A Na-22 source is placed in front of a reference detector and at the side of the dual-ended readout DOI-TOF PET module in five steps of 2 mm, 6 mm, 10 mm, 14 mm, and 18 mm to measure the DOI, coincidence timing resolutions (CTRs), and mean-times. The full-width-half-maximums (FWHMs) of DOI resolutions and CTRs varied from 3.0 mm to 3.8 mm, with an average of 3.5 mm, and from 333 ps to 367 ps, with an average of 349 ps, respectively. The average of the slopes of the mean-time versus DOI position, for the 36 crystals, was -0.60 +/- 1.68 ps/nm, which was consistent with the null value. The dual-ended readout DOI-TOF PET module based on the mean-time method produced both good DOI and CTRs, and consistent signal arrival times. The found solution would be the most advantageous in the small aperture PET systems, such as those for brain and breast imaging.
引用
收藏
页数:15
相关论文
共 23 条
[1]   Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setup [J].
Borghi, Giacomo ;
Tabacchini, Valerio ;
Bakker, Rene ;
Schaart, Dennis R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
[2]   A 32 mm x 32 mm x 22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI [J].
Borghi, Giacomo ;
Peet, Bart Jan ;
Tabacchini, Valerio ;
Schaart, Dennis R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13) :4929-4949
[3]   Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector [J].
Chang, Chen-Ming ;
Cates, Joshua W. ;
Levin, Craig S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) :258-271
[4]   Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays [J].
Du, Junwei ;
Bai, Xiaowei ;
Gola, Alberto ;
Acerbi, Fabio ;
Ferri, Alessandro ;
Piemonte, Claudio ;
Yang, Yongfeng ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
[5]   Improving the Accuracy of Simultaneously Reconstructed Activity and Attenuation Maps Using Deep Learning [J].
Hwang, Donghwi ;
Kim, Kyeong Yun ;
Kang, Seung Kwan ;
Seo, Seongho ;
Paeng, Jin Chul ;
Lee, Dong Soo ;
Lee, Jae Sung .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (10) :1624-1629
[6]   A Dual-Ended Readout Detector Using a Meantime Method for SiPM TOF-DOI PET [J].
Kang, Han Gyu ;
Ko, Guen Bae ;
Rhee, June Tak ;
Kim, Kyeong Min ;
Lee, Jae Sung ;
Hong, Seong Jong .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) :1935-1943
[7]  
Knoll G., 2010, Radiation detection and measurement
[8]   Single transmission-line readout method for silicon photomultiplier based time-of-flight and depth-of-interaction PET [J].
Ko, Guen Bae ;
Lee, Jae Sung .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06) :2194-2207
[9]   Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications [J].
Ko, Guen Bae ;
Lee, Jae Sung .
MEDICAL PHYSICS, 2015, 42 (01) :510-520
[10]   Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding [J].
Kolb, A. ;
Parl, C. ;
Mantlik, F. ;
Liu, C. C. ;
Lorenz, E. ;
Renker, D. ;
Pichler, B. J. .
MEDICAL PHYSICS, 2014, 41 (08) :430-438