Advanced anterior segment imaging in keratoconus: a review

被引:36
作者
Gokul, Akilesh [1 ]
Vellara, Hans R. [1 ]
Patel, Dipika V. [1 ]
机构
[1] Univ Auckland, Fac Med & Hlth Sci, New Zealand Natl Eye Ctr, Dept Ophthalmol, Auckland, New Zealand
关键词
corneal topography; imaging system; in vivo confocal microscopy; keratoconus; OPTICAL COHERENCE TOMOGRAPHY; VIVO CONFOCAL MICROSCOPY; OCULAR RESPONSE ANALYZER; COLLAGEN CROSS-LINKING; ACUTE CORNEAL HYDROPS; BASAL NERVE PLEXUS; BIOMECHANICAL PROPERTIES; FRUSTE KERATOCONUS; THICKNESS; EYES;
D O I
10.1111/ceo.13108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Advances in anterior segment imaging have enhanced our ability to detect keratoconus in its early stages and characterize the pathologic changes that occur. Computerized corneal tomography has elucidated the alterations in shape of the anterior and posterior corneal surfaces and alterations in thickness as the disease progresses. Automated screening indices such as the keratoconus screening index were developed to assist in detecting keratoconus in suspicious cases. In vivo assessment of keratoconic corneas has revealed that compromised corneal biomechanics can now be measured clinically. Optical coherence tomography has demonstrated alterations in corneal epithelial thickness and distribution in keratoconus, has a role in assessing Descemet's membrane detachment in acute corneal hydrops (ACH) and the depth of the demarcation line following corneal collagen cross-linking. In vivo confocal microscopy has exhibited cellular changes that occur in keratoconus and provided insight into cellular events that may be related to the development of neovascularization in ACH.
引用
收藏
页码:122 / 132
页数:11
相关论文
共 59 条
  • [1] Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer
    Ali, Noor Q.
    Patel, Dipika V.
    McGhee, Charles N. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3651 - 3659
  • [2] Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
    Ambrosio, Renato, Jr.
    Ramos, Isaac
    Luz, Allan
    Faria, Fernando Correa
    Steinmueller, Andreas
    Krug, Matthias
    Belin, Michael W.
    Roberts, Cynthia Jane
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 99 - 102
  • [3] Anterior Segment Optical Coherence Tomography Features of Acute Corneal Hydrops
    Basu, Sayan
    Vaddavalli, Pravin K.
    Vemuganti, Geeta K.
    Ali, Md Hasnat
    Murthy, Somasheila I.
    [J]. CORNEA, 2012, 31 (05) : 479 - 485
  • [4] Scheimpflug imaging for keratoconus and ectatic disease
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) : 401 - 406
  • [5] Evaluation of Contact Lens-Induced Changes in Keratoconic Corneas Using In Vivo Confocal Microscopy
    Bitirgen, Gulfidan
    Ozkagnici, Ahmet
    Malik, Rayaz A.
    Oltulu, Refik
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5385 - 5391
  • [6] Optical Coherence Tomography and Confocal Microscopy Following Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus
    Bouheraoua, Nacim
    Jouve, Lea
    El Sanharawi, Mohamed
    Sandali, Otman
    Temstet, Cyrille
    Loriaut, Patrick
    Basli, Elena
    Borderie, Vincent
    Laroche, Laurent
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7601 - 7609
  • [7] CORNEAL TOPOGRAPHY - HISTORY, TECHNIQUE, AND CLINICAL USES
    BRODY, J
    WALLER, S
    WAGONER, M
    [J]. INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (03) : 197 - 207
  • [8] Corneal biomechanical measurements before and after laser in situ keratomileusis
    Chen, Michael C.
    Lee, Nancy
    Bourla, Nirit
    Hamilton, D. Rex
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) : 1886 - 1891
  • [9] Changes in Corneal Sensation and Ocular Surface in Patients With Asymmetrical Keratoconus
    Cho, Kyong Jin
    Mok, Jee Won
    Choi, Min Yeong
    Kim, Ja-yeon
    Joo, Choun-Ki
    [J]. CORNEA, 2013, 32 (02) : 205 - 210
  • [10] Evaluation of Corneal Thickness and Volume Parameters of Subclinical Keratoconus Using a Pentacam Scheimflug System
    Cui, Jing
    Zhang, Xue
    Hu, Qi
    Zhou, Wen-Yan
    Yang, Fan
    [J]. CURRENT EYE RESEARCH, 2016, 41 (07) : 923 - 926