Aortic Valve Area on 64-MDCT Correlates with Transesophageal Echocardiography in Aortic Stenosis

被引:30
|
作者
LaBounty, Troy M. [1 ]
Sundaram, Baskaran [2 ]
Agarwal, Prachi [2 ]
Armstrong, William A. [1 ]
Kazerooni, Ella A. [2 ]
Yamada, Elina [1 ]
机构
[1] Univ Michigan, Ctr Cardiovasc, Dept Internal Med, Div Cardiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Ctr Cardiovasc, Dept Radiol, Div Cardiothorac Radiol, Ann Arbor, MI 48109 USA
关键词
aortic valve; aortic valve stenosis; CT; transesophageal echocardiography;
D O I
10.2214/AJR.07.3703
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to compare aortic valve area and calcification between CT and echocardiography. MATERIALS AND METHODS. We performed retrospective evaluation of 80 consecutive patients with aortic stenosis (AS) who underwent ECG-gated 64-MDCT and transesophageal echocardiography (TEE). Valve planimetry was feasible in 80 patients with CT and in 63 patients with TEE; valve area by transthoracic echocardiography was available in 46 patients. Valve calcification grade on CT was compared with TEE. One cardiologist (echocardiography) and two radiologists (CT) independently and blindly reviewed the studies. Pearson's correlations, Spearman's rank correlations, paired Student's t tests, and weighted kappa tests were used. RESULTS. The median valve area on TEE was 0.7 +/- 0.9 cm(2). There was excellent correlation (n = 80; r = 0.91, p < 0.001) and no difference (0.06 +/- 0.26 cm2, p = 0.06) between CT readers. There was strong correlation (n = 63; r = 0.84, p < 0.001) and no difference (-0.06 +/- 0.48 cm(2), p = 0.33) in valve area between CT and TEE, with a strong correlation (n = 46; r = 0.83, p < 0.001) and small overestimation (0.17 +/- 0.33 cm(2), p < 0.001) in valve area with CT versus transthoracic echocardiography. The sensitivity and specificity of CT to detect severe aortic stenosis compared with TEE were 92.1% (35/38) and 89.5% (17/19), respectively. Calcification grade had fair agreement between CT readers and TEE (kappa = 0.34 and 0.37, respectively). CONCLUSION. Aortic valve area on CT strongly correlates with echocardiography and has excellent sensitivity and specificity to detect severe stenosis. Valve calcification has fair agreement between studies. Valve area and calcification should be reported on CT angiography in patients with AS.
引用
收藏
页码:1652 / 1658
页数:7
相关论文
共 50 条
  • [21] Quantification of Aortic Valve Stenosis Head-to-Head Comparison of 64-Slice Spiral Computed Tomography With Transesophageal and Transthoracic Echocardiography and Cardiac Catheterization
    Lembcke, Alexander
    Kivelitz, Dietmar E.
    Borges, Adrian C.
    Lachnitt, Andre
    Hein, Patrick A.
    Dohmen, Pascal M.
    Thiele, Holger
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 7 - 14
  • [22] Transcatheter Transapical Aortic Valve Implantation Primarily Guided by Transesophageal Echocardiography
    Bagur, Rodrigo
    Dumont, Eric
    de Larochelliere, Robert
    Doyle, Daniel
    Villeneuve, Jacques
    Lemieux, Jerome
    Bergeron, Sebastien
    Cote, Melanie
    Bertrand, Olivier F.
    Pibarot, Philippe
    Rodes-Cabau, Josep
    CIRCULATION, 2010, 122 (21)
  • [23] Flail aortic valve in systemic lupus erythematosus: Diagnosis by transesophageal echocardiography
    Mehta, RK
    Agrawal, GG
    Nanda, NC
    Tirtaman, C
    Pacifico, A
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (04): : 431 - 434
  • [24] Papillary fibroelastoma of the aortic valve: incidental finding with intraoperative transesophageal echocardiography
    Botta, Luca
    Dell'Amore, Andrea
    Pilato, Emanuele
    Leone, Ornella
    Di Bartolomeo, Roberto
    CARDIOVASCULAR PATHOLOGY, 2007, 16 (01) : 59 - 60
  • [25] Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis
    Katarzyna Mizia-Stec
    Piotr Pysz
    Marek Jasiński
    Tomasz Adamczyk
    Agnieszka Drzewiecka-Gerber
    Artur Chmiel
    Michał Krejca
    Andrzej Bochenek
    Stanisław Woś
    Maciej Sosnowski
    Zbigniew Gąsior
    Maria Trusz-Gluza
    Michał Tendera
    The International Journal of Cardiovascular Imaging, 2012, 28 : 343 - 352
  • [26] Coronary ostial stenosis detected by transesophageal echocardiography after aortic valve replacement: a case report
    Naomi Ono
    Toshiyuki Sawai
    Hisanari Ishii
    JA Clinical Reports, 3 (1)
  • [27] Using cardiac magnetic resonance tomography for assessment of aortic valve area in aortic valve stenosis
    Malyar, Nasser M.
    Schlosser, Thomas
    Buck, Thomas
    Erbel, Raimund
    HERZ, 2006, 31 (07) : 650 - 657
  • [28] Comparison of accuracy of aortic valve area assessment in aortic stenosis by real time three-dimensional echocardiography in biplane mode versus two-dimensional transthoracic and transesophageal echocardiography
    Blot-Souletie, Nathalie
    Hebrard, Aurelien
    Acar, Philippe
    Carrie, Didier
    Puel, Jacques
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10): : 1065 - 1072
  • [29] A quadricuspid aortic valve diagnosed by transesophageal echocardiography: Report of a case
    Takashi Watanabe
    Yasuyuki Hosoda
    Shiro Sasaguri
    Yumiko Aikawa
    Surgery Today, 1998, 28 : 1102 - 1104
  • [30] A quadricuspid aortic valve diagnosed by transesophageal echocardiography: Report of a case
    Watanabe, T
    Hosoda, Y
    Sasaguri, S
    Aikawa, Y
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1998, 28 (10): : 1102 - 1104