Glucose meters - fit for clinical purpose

被引:14
|
作者
Tirimacco, Rosy
Koumantakis, George [1 ]
Erasmus, Rajiv [2 ,3 ]
Mosca, Andrea [4 ]
Sandberg, Sverre [5 ]
Watson, Ian D.
Goldsmith, Barbara [6 ]
Gillery, Philippe
机构
[1] Roche Diagnost, Sydney, NSW, Australia
[2] Natl Hlth Labs, Cape Town, South Africa
[3] Univ Stellenbosch, Cape Town, South Africa
[4] Univ Milan, Dept Pathophysiol & Transplantat, Milan, Italy
[5] Haukeland Hosp, Lab Clin Biochem, N-5021 Bergen, Norway
[6] Temple Univ, Sch Med, Philadelphia, PA 19122 USA
关键词
diabetes mellitus; glucose meters; point-of-care testing; quality specifications; APPROVED IFCC RECOMMENDATION;
D O I
10.1515/cclm-2013-0011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Glucose meters have improved considerably since they were first introduced in 1960, but many questions are being asked about their accuracy and reliability in certain clinical situations. These questions have arisen because of the widespread use of these meters into clinical areas they have not been designed for such as critical care. The lack of understanding by some health professionals on factors that affect glucose results, such as sample type, glucose test strip methodologic limitations, calibration to recognized reference methods, and interferences, leads to misleading results that may affect patient care. Much debate continues on the quality specifications for glucose meters. Because there is an extensive use of these meters in different clinical scenarios, the setting of quality specifications will remain a challenge for regulatory and professional organizations. In this article, we have attempted to collect and provide relevant information addressing the limitations above. Pivotal to obtaining the best quality of results is education, particularly for diabetic patients monitoring their glucose. The International Federation of Clinical Chemistry and Laboratory Medicine through its Point-of-Care Testing Task Force and its Working Group on Glucose Point-of-Care Testing is actively working toward improving the quality of glucose results by improving education and working with the industry to improve strip performance and work toward the better standardization of strips.
引用
收藏
页码:943 / 952
页数:10
相关论文
共 50 条
  • [31] Blood Glucose Meters
    Pray, W. Steven
    Pray, Gabriel E.
    US PHARMACIST, 2013, 38 (10) : 8 - 8
  • [32] Clinical and statistical evaluation of self-monitoring blood glucose meters
    Poirier, JY
    Le Prieur, N
    Campion, L
    Guilhem, I
    Allannic, H
    Maugendre, D
    DIABETES CARE, 1998, 21 (11) : 1919 - 1924
  • [33] Mouldy concrete is fit for purpose
    Chaffey, Nigel
    ANNALS OF BOTANY, 2018, 121 (07) : VI - VII
  • [34] Antiviral drugs fit for a purpose
    Ming Luo
    Nature, 2006, 443 : 37 - 38
  • [35] External examining: fit for purpose?
    Bloxham, Sue
    Price, Margaret
    STUDIES IN HIGHER EDUCATION, 2015, 40 (02) : 195 - 211
  • [36] Validation of home blood glucose meters with respect to clinical and analytical approaches
    Brunner, GA
    Ellmerer, M
    Sendlhofer, G
    Wutte, A
    Trajanoski, Z
    Schaupp, L
    Quehenberger, F
    Wach, P
    Krejs, GJ
    Pieber, TR
    DIABETES CARE, 1998, 21 (04) : 585 - 590
  • [37] LABORATORY ASSESSMENT OF GLUCOSE METERS AND RELIABILITY OF CLINICAL-PERFORMANCE - REPLY
    BERNBVAUM, M
    MOOARDIAN, AD
    ALBERT, S
    HOFFMAN, J
    LABORATORY MEDICINE, 1994, 25 (03) : 189 - 191
  • [38] Ensuring the workforce is fit for purpose
    Bond, Christine
    INTERNATIONAL JOURNAL OF PHARMACY PRACTICE, 2020, 28 (02) : 117 - 117
  • [39] DESIGNING THE SHAFT TO FIT THE PURPOSE
    POLLARD, G
    PROCESS ENGINEERING, 1980, (JUN) : 81 - &
  • [40] Notified bodies: are they fit for purpose?
    Cohen, Deborah
    BRITISH MEDICAL JOURNAL, 2012, 345