Measurement of intraspecimen variations in vertebral cancellous bone architecture

被引:29
|
作者
Kothari, M
Keaveny, TM
Lin, JC
Newitt, DC
Majumdar, S
机构
[1] Univ Calif San Francisco, Dept Radiol, Magnet Resonance Sci Ctr, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley, Dept Mech Engn, Orthopaed Biomech Lab, Berkeley, CA 94720 USA
[3] Univ Calif San Francisco, Dept Orthoped Surg, San Francisco, CA 94143 USA
关键词
bone; cancellous; morphometry; osteoporosis; anisotropy;
D O I
10.1016/S8756-3282(99)00161-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A three-dimensional technique was developed for the quantification of the number and cross-sectional geometry of individual trabeculae oriented along a given direction. As an example application, the number of vertical and horizontal trabeculae and their respective cross-sectional geometry were determined for a set of six vertebral cancellous bone specimens (L3-L4 female vertebral bodies; age range 39-63 years). Three-dimensional optical images at a spatial resolution of 20 mu m were obtained using an automated serial milling technique. The thickness distributions were generally right skewed. The mean true thickness for both the vertically and horizontally oriented trabeculae showed a strong relationship with volume fraction (vertical: r(2) = 0.86; p < 0.05; horizontal: r(2) = 0.80; p < 0.05), and mean trabecular thickness (Tb,Th,) (vertical: r(2) = 0.81; p < 0.05; horizontal: r(2) = 0.72; p < 0.05). The horizontal trabeculae were greater in number and were thinner than the vertical trabeculae, The coefficient of variation of the intraspecimen vertical trabecular thicknesses ranged from 25% to 42%, and showed a weak, albeit insignificant, positive correlation with volume fraction (r(2) = 0.46). The findings demonstrated substantial intraspecimen variations exist in trabecular thickness that are not related to volume fraction. Further studies are recommended to determine the potential role of such intraspecimen variations in architecture on biomechanical properties. (C) 1999 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [31] Age-related differences in microstructure, density and biomechanics of vertebral cancellous bone of Chinese males
    Liu, Guo-Min
    Xu, Chuan-Jie
    Kong, Ning
    Zhu, Xiao-Min
    Zhang, Xing-Yi
    Yao, Yan
    AGING MALE, 2012, 15 (04) : 233 - 239
  • [32] The biomechanical effects of osteoporosis vertebral augmentation with cancellous bone granules or bone cement on treated and adjacent non-treated vertebral bodies: A finite element evaluation
    Zhang, Licheng
    Yang, Guojing
    Wu, Lijun
    Yu, Binfeng
    CLINICAL BIOMECHANICS, 2010, 25 (02) : 166 - 172
  • [33] Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy
    Jia, Yan
    Han, Shuai
    Li, Boyi
    Liu, Chengcheng
    Ta, Dean
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2024, 155 (04) : 2670 - 2686
  • [34] Cancellous bone biomechanics
    Fyhrie, DP
    Kimura, JH
    JOURNAL OF BIOMECHANICS, 1999, 32 (11) : 1139 - 1148
  • [35] Mechanical properties of cancellous bone of the distal humerus
    Dunham, CE
    Takaki, SE
    Johnson, JA
    Dunning, CE
    CLINICAL BIOMECHANICS, 2005, 20 (08) : 834 - 838
  • [36] Cancellous bone architecture: Advantages of nonorthogonal trabecular alignment under multidirectional joint loading
    Pidaparti, RMV
    Turner, CH
    JOURNAL OF BIOMECHANICS, 1997, 30 (09) : 979 - 983
  • [37] Dynamic stochastic simulation of cancellous bone resorption
    Langton, CM
    Haire, TJ
    Ganney, PS
    Dobson, CA
    Fagan, MJ
    BONE, 1998, 22 (04) : 375 - 380
  • [38] A sensitive stain for aluminum in undecalcified cancellous bone
    Walton, J. R.
    Diamond, T. H.
    Kumar, S.
    Murrell, G. A. C.
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2007, 101 (09) : 1285 - 1290
  • [39] Patient-specific microarchitecture of vertebral cancellous bone: A peripheral quantitative computed tomographic and histological study
    Banse, X
    Devogelaer, JP
    Grynpas, M
    BONE, 2002, 30 (06) : 829 - 835
  • [40] Ultrasonic Scanner for In Vivo Measurement of Cancellous Bone Properties From Backscattered Data
    Litniewski, Jerzy
    Cieslik, Lucyna
    Lewandowski, Marcin
    Tymkiewicz, Ryszard
    Zienkiewicz, Boguslaw
    Nowicki, Andrzej
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) : 1470 - 1477