Measurement of intraspecimen variations in vertebral cancellous bone architecture

被引:29
|
作者
Kothari, M
Keaveny, TM
Lin, JC
Newitt, DC
Majumdar, S
机构
[1] Univ Calif San Francisco, Dept Radiol, Magnet Resonance Sci Ctr, San Francisco, CA 94143 USA
[2] Univ Calif Berkeley, Dept Mech Engn, Orthopaed Biomech Lab, Berkeley, CA 94720 USA
[3] Univ Calif San Francisco, Dept Orthoped Surg, San Francisco, CA 94143 USA
关键词
bone; cancellous; morphometry; osteoporosis; anisotropy;
D O I
10.1016/S8756-3282(99)00161-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A three-dimensional technique was developed for the quantification of the number and cross-sectional geometry of individual trabeculae oriented along a given direction. As an example application, the number of vertical and horizontal trabeculae and their respective cross-sectional geometry were determined for a set of six vertebral cancellous bone specimens (L3-L4 female vertebral bodies; age range 39-63 years). Three-dimensional optical images at a spatial resolution of 20 mu m were obtained using an automated serial milling technique. The thickness distributions were generally right skewed. The mean true thickness for both the vertically and horizontally oriented trabeculae showed a strong relationship with volume fraction (vertical: r(2) = 0.86; p < 0.05; horizontal: r(2) = 0.80; p < 0.05), and mean trabecular thickness (Tb,Th,) (vertical: r(2) = 0.81; p < 0.05; horizontal: r(2) = 0.72; p < 0.05). The horizontal trabeculae were greater in number and were thinner than the vertical trabeculae, The coefficient of variation of the intraspecimen vertical trabecular thicknesses ranged from 25% to 42%, and showed a weak, albeit insignificant, positive correlation with volume fraction (r(2) = 0.46). The findings demonstrated substantial intraspecimen variations exist in trabecular thickness that are not related to volume fraction. Further studies are recommended to determine the potential role of such intraspecimen variations in architecture on biomechanical properties. (C) 1999 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [1] Multiphasic modelling of bone-cement injection into vertebral cancellous bone
    Bleiler, Christian
    Wagner, Arndt
    Stadelmann, Vincent A.
    Windolf, Markus
    Koestler, Harald
    Boger, Andreas
    Gueorguiev-Rueegg, Boyko
    Ehlers, Wolfgang
    Roehrle, Oliver
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (01) : 37 - 57
  • [2] STIFFENING EFFECTS OF CORTICAL BONE ON VERTEBRAL CANCELLOUS BONE IN-SITU
    BRYCE, R
    ASPDEN, RM
    WYTCH, R
    SPINE, 1995, 20 (09) : 999 - 1003
  • [3] 3-DIMENSIONAL PHOTOGRAPHIC STUDY OF CANCELLOUS BONE IN HUMAN 4TH LUMBAR VERTEBRAL BODIES
    JAYASINGHE, JAP
    JONES, SJ
    BOYDE, A
    ANATOMY AND EMBRYOLOGY, 1994, 189 (03): : 259 - 274
  • [4] Structural and material mechanical properties of human vertebral cancellous bone
    Nicholson, PHF
    Cheng, XG
    Lowet, G
    Boonen, S
    Davie, MWJ
    Dequeker, J
    Van der Perre, G
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (08) : 729 - 737
  • [5] Biomechanical effects of intraspecimen variations in trabecular architecture: A three-dimensional finite element study
    Yeh, OC
    Keaveny, TM
    BONE, 1999, 25 (02) : 223 - 228
  • [6] MORPHOLOGICAL ANALYSIS OF VERTEBRAL CANCELLOUS BONE IN QUANTITATIVE-CT
    REUTHER, G
    DOREN, M
    MONTAG, M
    PETERS, PE
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (03): : 264 - 269
  • [7] Variations in three-dimensional cancellous bone architecture of the proximal femur in female hip fractures and in controls
    Ciarelli, TE
    Fyhrie, DP
    Schaffler, MB
    Goldstein, SA
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (01) : 32 - 40
  • [8] Inhomogeneity of human vertebral cancellous bone: Systematic density and structure patterns inside the vertebral body
    Banse, X
    Devogelaer, JP
    Munting, E
    Delloye, C
    Cornu, O
    Grynpas, M
    BONE, 2001, 28 (05) : 563 - 571
  • [9] 3D micro-CT analysis of cancellous bone architecture
    Rossi, M
    Casali, F
    Romani, D
    Carabini, ML
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 349 - 358
  • [10] Fractal properties of cancellous bone of the iliac crest in vertebral crush fracture
    Fazzalari, NL
    Parkinson, IH