A novel process for the preparation of Cys-Si-NIPAM as a stationary phase of hydrophilic interaction liquid chromatography (HILIC)

被引:10
|
作者
Fan, Fangbin [1 ,2 ]
Wang, Licheng [1 ]
Li, Yijing [1 ]
Wang, Xusheng [1 ]
Lu, Xiaofeng [1 ]
Guo, Yong [1 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
L-cysteine; N-Isopropyl acrylamide; Cross-linking polymerization; Thiol-ene click reaction; Silica spheres; Hydrophilic interaction liquid chromatography; SILICA-GEL; HPLC; ENANTIOMERS;
D O I
10.1016/j.talanta.2020.121154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
L-Cysteine (L-Cys) and N-Isopropyl acrylamide (NIPAM)-modified silica spheres as a novel stationary phase for hydrophilic interaction liquid chromatography (HILIC) was produced firstly by cross-linking polymerization. Some characterizations in this article confirmed that the synthesis of Cys-Si-NIPAM is successful. Some polymer layers can be observed through transmission electron microscopy (TEM). In addition, through nitrogen adsorption porosity method, scanning electron microscopy (SEM), thermal gravimetric analysis (TGA) and other characterization methods, we can find the significant changes after modify. It has good hydrophilic property and higher column effect than bare silica column, Si-Cys column and Si-NIPAM column under the same conditions. It has good separation effect for some hydrophilic analytes such as 5 nucleosides and nucleoside bases, 5 amino acids, 4 sulfonamide drugs and 10 saccharides. The effects including column temperature, pH and organic solvent content on chromatographic performance were studied, which proved that hydrophilic interactions can be simultaneously existed between the stationary phase and the analytes. In addition, reproducibility and efficiency of the Cys-Si-NIPAM column was also investigated, the results illustrated that the stationary phase have passable stability (the intraday RSDs 0.08-0.44%, n = 3 and the interday RSD 0.46-3.50%, n = 3) and ideal efficiency (plates per meter, similar to 45700 plates/m). In conclusion, the preparation process of this hydrophilic liquid chromatography stationary phase is not only simple, but also can meet the basic requirements for the separation of hydrophilic analytes.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Stationary phase effects in hydrophilic interaction liquid chromatographic separation of oligonucleotides
    Abernathy, Scott
    Rayhan, Asif
    Limbach, Patrick A.
    ANALYST, 2024, 150 (01) : 185 - 196
  • [32] Chromatographic evaluation and application of nitrogenous heterocyclic ring-bonded stationary phase in hydrophilic interaction liquid chromatography
    Song, Chunying
    Jin, Gaowa
    Guo, Zhimou
    Yu, Dongping
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1734
  • [33] Evaluation of the properties of a superficially porous silica stationary phase in hydrophilic interaction chromatography
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1193 (1-2) : 85 - 91
  • [34] Separation and identification of oligonucleotides by hydrophilic interaction liquid chromatography (HILIC)-inductively coupled plasma mass spectrometry (ICPMS)
    Easter, Renee N.
    Kroening, Karolin K.
    Caruso, Joseph A.
    Limbach, Patrick A.
    ANALYST, 2010, 135 (10) : 2560 - 2565
  • [35] Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms
    Doulou, Eleni
    Kalomiraki, Marina
    Parla, Anthi
    Thermos, Kyriaki
    Chaniotakis, Nikos A.
    Panderi, Irene
    ANALYTICA, 2021, 2 (04): : 121 - 129
  • [36] Preparation and Evaluation of Poly-l-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Yuanyuan Li
    Zhigang Xu
    Yaoyao Feng
    Xiaoyan Liu
    Tong Chen
    Haixia Zhang
    Chromatographia, 2011, 74 : 523 - 530
  • [37] Preparation and Evaluation of Poly-L-Lysine Stationary Phase for Hydrophilic Interaction/Reversed-Phase Mixed-Mode Chromatography
    Li, Yuanyuan
    Xu, Zhigang
    Feng, Yaoyao
    Liu, Xiaoyan
    Chen, Tong
    Zhang, Haixia
    CHROMATOGRAPHIA, 2011, 74 (7-8) : 523 - 530
  • [38] Preparation and evaluation of 2-methylimidazolium-functionalized silica as a mixed-mode stationary phase for hydrophilic interaction and anion-exchange chromatography
    Yang, Beibei
    Liu, Houmei
    Chen, Jia
    Guan, Ming
    Qiu, Hongdeng
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1468 : 79 - 85
  • [39] Silica-Based Stationary Phase with Surface Bound N-Acetyl-glucosamine for Hydrophilic Interaction Liquid Chromatography
    Rajendiran, Vaithilingam
    El Rassi, Ziad
    MOLECULES, 2023, 28 (20):
  • [40] Facile one-pot synthesized hydrothermal carbon from cyclodextrin: A stationary phase for hydrophilic interaction liquid chromatography
    Zhao, Xingyun
    Liu, Shengju
    Peng, Jiaxi
    Li, Xin
    Niu, Huan
    Zhang, Hongyan
    Wang, Li
    Wu, Ren'an
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1585 : 144 - 151