Tackling reproducibility in microcantilever biosensors: a statistical approach for sensitive and specific end-point detection of immunoreactions

被引:22
作者
Kosaka, Priscila M. [1 ]
Tamayo, Javier [1 ]
Ruz, Jose J. [1 ]
Puertas, Sara [2 ]
Polo, Ester [2 ]
Grazu, Valeria [2 ]
de la Fuente, Jesus M. [2 ]
Calleja, Montserrat [1 ]
机构
[1] CSIC, Inst Microelect Madrid, Madrid 28760, Spain
[2] Univ Zaragoza, Inst Nanociencia Aragon, Zaragoza, Spain
基金
欧洲研究理事会;
关键词
NANOMECHANICAL CANTILEVER ARRAY; LABEL-FREE DETECTION; BIOLOGICAL DETECTION; PROTEIN MICROARRAYS; CHALLENGES; BINDING; NANOPARTICLES; BIOMOLECULES; PERFORMANCE; EFFICIENCY;
D O I
10.1039/c2an36192b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the last decade, microcantilever biosensors have shown enormous potential for highly sensitive label-free detection of nucleic acid and proteins. Despite the enormous advances, the promise of applications of this technology in the biomedical field has been frustrated because of its low reproducibility. Here we tackle the reproducibility issue in microcantilever biosensors and provide the guidelines to minimize the deviations in the biosensor response between different assays. We use as a model system the label-free end-point detection of horseradish peroxidase. We choose the end-point detection mode because of its suitability for implementation in the clinical field that requires simplicity and point-of-care capability. Our study comprises the analysis of 1012 cantilevers with different antibody surface densities, two blocking strategies based on polyethylene-glycol (PEG) and bovine serum albumin (BSA) and stringent controls. The study reveals that the performance of the assay critically depends on both antibody surface density and blocking strategies. We find that the optimal conditions involve antibody surface densities near but below saturation and blocking with PEG. We find that the surface stress induced by the antibody-antigen binding is significantly correlated with the surface stress generated during the antibody attachment and blocking steps. The statistical correlation is harnessed to identify immobilization failure or success, and thus enhancing the specificity and sensitivity of the assay. This procedure enables achieving rates of true positives and true negatives of 90% and 91% respectively. The detection limit is of 10 ng mL(-1) (250 pM) that is similar to the detection limit obtained in our enzyme-linked immunosorbent assay (ELISA) and at least two orders of magnitude smaller than that achieved with well-established label-free biosensors such as a quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) sensor.
引用
收藏
页码:863 / 872
页数:10
相关论文
共 50 条
[1]   Estimation of sensitivity for refractive index and immunoreaction in a surface plasmon resonance sensor probe [J].
Akimoto, T ;
Sasaki, S ;
Ikebukuro, K ;
Karube, I .
ANALYTICA CHIMICA ACTA, 2000, 417 (02) :125-131
[2]   Development of nanomechanical biosensors for detection of the pesticide DDT [J].
Alvarez, M ;
Calle, A ;
Tamayo, J ;
Lechuga, LM ;
Abad, A ;
Montoya, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :649-653
[3]   Comparative advantages of mechanical biosensors [J].
Arlett, J. L. ;
Myers, E. B. ;
Roukes, M. L. .
NATURE NANOTECHNOLOGY, 2011, 6 (04) :203-215
[4]   Label-free protein assay based on a nanomechanical cantilever array [J].
Arntz, Y ;
Seelig, JD ;
Lang, HP ;
Zhang, J ;
Hunziker, P ;
Ramseyer, JP ;
Meyer, E ;
Hegner, M ;
Gerber, C .
NANOTECHNOLOGY, 2003, 14 (01) :86-90
[5]   Cantilever-like micromechanical sensors [J].
Boisen, Anja ;
Dohn, Soren ;
Keller, Stephan Sylvest ;
Schmid, Silvan ;
Tenje, Maria .
REPORTS ON PROGRESS IN PHYSICS, 2011, 74 (03)
[6]   High throughput label-free platform for statistical bio-molecular sensing [J].
Bosco, Filippo G. ;
Hwu, En-Te ;
Chen, Ching-Hsiu ;
Keller, Stephan ;
Bache, Michael ;
Jakobsen, Mogens H. ;
Hwang, Ing-Shouh ;
Boisen, Anja .
LAB ON A CHIP, 2011, 11 (14) :2411-2416
[7]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[8]   Weighing of biomolecules, single cells and single nanoparticles in fluid [J].
Burg, Thomas P. ;
Godin, Michel ;
Knudsen, Scott M. ;
Shen, Wenjiang ;
Carlson, Greg ;
Foster, John S. ;
Babcock, Ken ;
Manalis, Scott R. .
NATURE, 2007, 446 (7139) :1066-1069
[9]   Low-noise polymeric nanomechanical biosensors [J].
Calleja, M ;
Tamayo, J ;
Nordström, M ;
Boisen, A .
APPLIED PHYSICS LETTERS, 2006, 88 (11)
[10]   Challenges for nanomechanical sensors in biological detection [J].
Calleja, Montserrat ;
Kosaka, Priscila M. ;
San Paulo, Alvaro ;
Tamayo, Javier .
NANOSCALE, 2012, 4 (16) :4925-4938