The effects of geometrical parameters of a corrugated channel with in out-of-phase arrangement

被引:59
作者
Mohammed, H. A. [1 ]
Abed, Azher M. [1 ,2 ]
Wahid, M. A. [1 ]
机构
[1] Univ Teknol Malaysia, Fac Mech Engn, Dept Thermofluids, Utm Skudai 81310, Johor Bahru, Malaysia
[2] Al Mustaqbal Univ Coll, Dept Air Conditioning & Refrigerat, Babylon, Iraq
关键词
Turbulent flow; Forced convection; Corrugated channel; Heat transfer enhancement; HEAT-TRANSFER CHARACTERISTICS; PRESSURE-DROP; FLUID-FLOW; EXCHANGER;
D O I
10.1016/j.icheatmasstransfer.2012.10.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Numerical investigations of forced turbulent convective flow and heat transfer in a corrugated channel of plate heat exchanger are carried out. The continuity, momentum and energy equations were solved by means of a finite volume method (FVM). The top and bottom walls of the corrugated channel are heated at constant heat flux boundary conditions. The effects of geometrical parameters of corrugated tilt angles, channel heights and wavy heights using water as a working fluid on the thermal and flow fields as well as on the performance of evaluation criterion are studied. The corrugated channel with three different corrugated tilt angles of 20 degrees, 40 degrees and 60 degrees with different channel heights of 12.5, 15 and 17.5 mm and different wavy heights of 2.5, 3.5 and 4.5 mm are tested. This investigation covers Reynolds number and heat flux in the range of 8000-20,000 and 0.4-6 kW/m(2), respectively. The numerical results indicate that the wavy angle of 60 degrees and wavy height of 2.5 mm with channel height of 17.5 mm are the optimum parameters and they have a significant effect on the heat transfer enhancement. It is found that using wavy channel is a suitable method to increase the thermal performance and getting higher compactness of the heat exchanger. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 34 条
[1]   Simplified numerical simulation to obtain heat transfer correlations for stirred yoghurt in a plate heat exchanger [J].
Afonso, Isabel M. ;
Cruz, Paulo ;
Maia, Joao M. ;
Melo, Luis F. .
FOOD AND BIOPRODUCTS PROCESSING, 2008, 86 (C4) :296-303
[2]   Experimental study on laminar flow forced-convection in a channel with upper V-corrugated plate heated by radiation [J].
Ali, AHH ;
Hanaoka, Y .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (10) :2107-2117
[3]   Investigation of the new corrugation pattern for low pressure plate condensers [J].
Arsenyeva, Olga ;
Tovazhnyansky, Leonid ;
Kapustenko, Petro ;
Perevertaylenko, Oleksander ;
Khavin, Gennadiy .
APPLIED THERMAL ENGINEERING, 2011, 31 (13) :2146-2152
[4]   Investigation of heat transfer and pressure drop in plate heat exchangers having different surface profiles [J].
Durmus, Aydin ;
Benli, Hueseyin ;
Kurtbas, Irfan ;
Gul, Hasan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (5-6) :1451-1457
[5]   Heat transfer and pressure drop in corrugated channels [J].
Elshafei, E. A. M. ;
Awad, M. M. ;
El-Negiry, E. ;
Ali, A. G. .
ENERGY, 2010, 35 (01) :101-110
[6]  
Elshafei E. A. M., 2008, THERMAL ISSUES EMERG
[7]  
Fernandes C. S., 2011, APPL THERM ENG, V31, P2146
[8]   Friction factors of power-law fluids in chevron-type plate heat exchangers [J].
Fernandes, Carla S. ;
Dias, Ricardo P. ;
Nobrega, Joao M. ;
Maia, Joao M. .
JOURNAL OF FOOD ENGINEERING, 2008, 89 (04) :441-447
[9]   Laminar flow in chevron-type plate heat exchangers:: CFD analysis of tortuosity, shape factor and friction factor [J].
Fernandes, Carla S. ;
Dias, Ricardo P. ;
Nobrega, Joao M. ;
Maia, Joao M. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2007, 46 (09) :825-833
[10]  
GRADECK M., 2002, J HEAT MASS TRANSFER, V48, P2587