Noise-Induced Change of Cortical Temporal Processing in Cochlear Implant Users

被引:9
|
作者
Han, Ji-Hye [1 ]
Lee, Jihyun [1 ]
Lee, Hyo-Jeong [1 ,2 ]
机构
[1] Lab Brain & Cognit Sci Convergence Med, Anyang, Peoples R China
[2] Hallym Univ, Dept Otorhinolaryngol Head & Neck Surg, Coll Med, 1 Hallimdaehak Gil, Chuncheon 24252, Peoples R China
基金
新加坡国家研究基金会;
关键词
Cochlear Implant; Noise-Induced; Auditory Evoked Potentials; Voice Onset Time; HEARING-LOSS; SPEECH; PERCEPTION; POTENTIALS; RESPONSES; SIGNALS; AGE;
D O I
10.21053/ceo.2019.01081
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives. Cochlear implant (CI) users typically report impaired ability to understand speech in noise. Speech understanding in CI users decreases with noise due to reduced temporal processing ability, and speech perceptual errors involve stop consonants distinguished by voice onset time (VOT). The current study examined the effects of noise on various speech perception tests while at the same time used cortical auditory evoked potentials (CAEPs) to quantify the change of neural processing of speech sounds caused by noise. We hypothesized that the noise effects on VOT processing can be reflected in N1/P2 measures, the neural changes relate to behavioral speech perception performances. Methods. Ten adult CI users and 15 normal-hearing (NH) people participated in this study. CAEPs were recorded from 64 scalp electrodes in both quiet and noise (signal-to-noise ratio +5 dB) and in passive and active (requiring consonant discrimination) listening. Speech stimulus was synthesized consonant-vowels with VOTs of 0 and 50 ins. N1-P2 amplitudes and latencies were analyzed as a function of listening condition. For the active condition, the P3b also was analyzed. Behavioral measures included a variety of speech perception tasks. Results. For good performing CI users, performance in most speech test was lower in the presence of noise masking. N1 and P2 latencies became prolonged with noise masking. The P3b amplitudes were smaller in CI groups compared to NH. The degree of P2 latency change (0 vs. 50 msVOT) was correlated with consonant perception in noise. Conclusion. The effects of noise masking on temporal processing can be reflected in cortical responses in CI users. N1/P2 latencies were more sensitive to noise masking than amplitude measures. Additionally, P2 responses appear to have a better relationship to speech perception in CI users compared to N1.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [21] Age-Related Temporal Processing Deficits in Word Segments in Adult Cochlear-Implant Users
    Xie, Zilong
    Gaskins, Casey R.
    Shader, Maureen J.
    Gordon-Salant, Sandra
    Anderson, Samira
    Goupell, Matthew J.
    TRENDS IN HEARING, 2019, 23
  • [22] Cross-domain processing of musical and vocal emotions in cochlear implant users
    Lehmann, Alexandre
    Paquette, Sebastien
    FRONTIERS IN NEUROSCIENCE, 2015, 9
  • [23] Comparative Analysis of Cortical Auditory Evoked Potential in Cochlear Implant Users
    Tavora-Vieira, Dayse
    Mandruzzato, Giacomo
    Polak, Marek
    Truong, Belinda
    Stutley, Alex
    EAR AND HEARING, 2021, 42 (06) : 1755 - 1769
  • [24] Interaction of sensory processing and balance in adult cochlear implant users
    Kutlu, Sevgi
    Aydogan, Zehra
    Bas, Banu
    Meco, Cem
    Tokgoz-Yilmaz, Suna
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (11) : 5651 - 5656
  • [25] Impact of Aging and the Electrode-to-Neural Interface on Temporal Processing Ability in Cochlear-Implant Users: Gap Detection Thresholds
    Shader, Maureen J.
    Gordon-Salant, Sandra
    Goupell, Matthew J.
    TRENDS IN HEARING, 2020, 24
  • [26] Assessing speech recognition abilities with digits in noise in cochlear implant and hearing aid users
    Kaandorp, Marre W.
    Smits, Cas
    Merkus, Paul
    Goverts, S. Theo
    Festen, Joost M.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (01) : 48 - 57
  • [27] Spatial Hearing by Bilateral Cochlear Implant Users With Temporal Fine-Structure Processing
    Ausili, Sebastian A.
    Agterberg, Martijn J. H.
    Engel, Andreas
    Voelter, Christiane
    Thomas, Jan Peter
    Brill, Stefan
    Snik, Ad F. M.
    Dazert, Stefan
    Van Opstal, A. John
    Mylanus, Emmanuel A. M.
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [28] Acoustic Change Complex Recorded in Hybrid Cochlear Implant Users
    Jeon, Eun Kyung
    Mussoi, Bruna S.
    Brown, Carolyn J.
    Abbas, Paul J.
    AUDIOLOGY AND NEURO-OTOLOGY, 2023, 28 (03) : 151 - 157
  • [29] Effectiveness of Directional Microphones in Bilateral/Bimodal Cochlear Implant Users-Impact of Spatial and Temporal Noise Characteristics
    Weissgerber, Tobias
    Rader, Tobias
    Baumann, Uwe
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : E551 - E557
  • [30] Noise-induced alterations in cochlear mechanics, electromotility, and cochlear amplification
    Jacob, Stefan
    Johansson, Cecilia
    Fridberger, Anders
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2013, 465 (06): : 907 - 917