Second-generation cryoballoon-based pulmonary vein isolation: Lessons from a five-year follow-up

被引:22
|
作者
Heeger, Christian-Hendrik [1 ,2 ,4 ]
Subin, Behnam [4 ]
Wissner, Erik [1 ,6 ]
Fink, Thomas [1 ]
Mathew, Shibu [4 ]
Maurer, Tilman [4 ]
Lemes, Christine [4 ]
Rillig, Andreas [5 ]
Wohlmuth, Peter [4 ]
Reissmann, Bruno [5 ]
Tilz, Roland Richard [1 ]
Ouyang, Feifan [1 ,3 ,4 ]
Kuck, Karl-Heinz [1 ,4 ]
Metzner, Andreas [4 ,5 ]
机构
[1] Univ Hosp Schleswig Holstein, Univ Heart Ctr Lubeck, Med Clin 2, Dept Cardiol Angiol & Intens Care Med, Lubeck, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Hamburg Kiel Lubeck, Lubeck, Germany
[3] Fuwai Hosp, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
[4] Asklepios Klin St Georg, Dept Cardiol, Hamburg, Germany
[5] Univ Heart Ctr Hamburg, Hamburg, Germany
[6] Univ Illinois, Div Cardiol, Chicago, IL USA
关键词
Atrial fibrillation; Pulmonary vein isolation; Cryoballoon; Long-term follow-up; PERSISTENT ATRIAL-FIBRILLATION; CATHETER ABLATION; BONUS-FREEZE; MANAGEMENT; INSIGHTS; OUTCOMES; SUCCESS; LESIONS;
D O I
10.1016/j.ijcard.2020.03.062
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB2) for atrial fibrillation (AF) treatment has demonstrated encouraging procedural success rates and mid-term results. However, longtermfollow-up data on outcome is sparse. The current study is reporting on five-year clinical outcomes following CB2-based PVI in patients with paroxysmal AF (PAF) and persistent AF (PersAF). Methods: A total of 139 patients underwent index CB2-based PVI patients (PAF: n= 105, 76% and PersAF: n= 34, 34%) in two electrophysiology centers. Freeze-cycle durationwas 240 s. After successful PVI a bonus freeze-cycle of the same duration was applied in the first 71 patients while the bonus-freeze was omitted in 68 following patients. Three patients (2.2%) were lost to follow-up. Results: After a median follow-up duration of 60months (interquartile range: 46, 72 months) 74/136 (54.4%) patients remained in stable sinus rhythm (PAF: 62/104, 59.6%; PersAF: 15/32, 46.9%). Significant differences were observed concerning 5-year clinical outcome between PAF and PersAF patients (p = 0.0315). After a mean of 1.32 +/- 0.6 procedures (2nd and 3rd procedure by radiofrequency ablation) and a median follow-up duration of 60 (37, 68) months 90/136 (66.2%) patients remained in stable sinus rhythm (PAF: 72/104 (69.2%), PersAF: 21/32 (65.6%), p = 0.0276). For the comparison of bonus-freeze vs no-bonus-freeze protocols no differences were observed (53.5% vs 57.4%, p = 0.650). Conclusions: The five-year single-procedure success rate for CB2-based PVI was 54.4% and increased to 66.2% following repeat RF-based procedures. No differences were detected comparing bonus-freeze and no-bonus-freeze protocols. (c) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [1] Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation - Impact of Different Ablation Strategies -
    Heeger, Christian-Hendrik
    Rexha, Enida
    Maack, Sabrina
    Rottner, Laura
    Fink, Thomas
    Mathew, Shibu
    Maurer, Tilman
    Lemes, Christine
    Rillig, Andreas
    Wohlmuth, Peter
    Reissmann, Bruno
    Tilz, Roland Richard
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    CIRCULATION JOURNAL, 2020, 84 (06) : 902 - 910
  • [2] Five-year experience with pulmonary vein isolation using the second-generation cryoballoon for treatment of persistent atrial fibrillation
    Akkaya, Ersan
    Berkowitsch, Alexander
    Zaltsberg, Sergej
    Greiss, Harald
    Hamm, Christian W.
    Sperzel, Johannes
    Neumann, Thomas
    Kuniss, Malte
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) : 1500 - 1507
  • [3] Once Isolated, Always Isolated? Incidence and Characteristics of Pulmonary Vein Reconduction After Second-Generation Cryoballoon-Based Pulmonary Vein Isolation
    Heeger, Christian-Hendrik
    Wissner, Erik
    Mathew, Shibu
    Deiss, Sebastian
    Lemes, Christine
    Rillig, Andreas
    Wohlmuth, Peter
    Reissmann, Bruno
    Tilz, Roland Richard
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (05) : 1088 - 1094
  • [4] What is the real recurrence rate after cryoballoon-based pulmonary vein isolation? Lessons from rhythm follow-up based on implanted cardiac devices with continuous atrial monitoring
    Heeger, Christian-Hendrik
    Tscholl, Verena
    Salloum, Omar
    Wissner, Erik
    Fink, Thomas
    Rottner, Laura
    Wohlmuth, Peter
    Bellmann, Barbara
    Roser, Mattias
    Mathew, Shibu
    Reissmann, Bruno
    Lemes, Christine
    Maurer, Tilman
    Santoro, Francesco
    Goldmann, Britta
    Landmesser, Ulf
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Rillig, Andreas
    Metzner, Andreas
    HEART RHYTHM, 2018, 15 (12) : 1844 - 1850
  • [5] Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol
    Metzner, Andreas
    Heeger, Christian-Hendrik
    Wohlmuth, Peter
    Reissmann, Bruno
    Rillig, Andreas
    Tilz, Roland Richard
    Mathew, Shibu
    Lemes, Christine
    Deiss, Sebastian
    Maurer, Tilman
    Saguner, Ardan
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Wissner, Erik
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (01) : 72 - 78
  • [6] Pulmonary Vein Stenosis After Second-Generation Cryoballoon Ablation
    Matsuda, Junji
    Miyazaki, Shinsuke
    Nakamura, Hiroaki
    Taniguchi, Hiroshi
    Kajiyama, Takatsugu
    Hachiya, Hitoshi
    Takagi, Takamitsu
    Iesaka, Yoshito
    Hirao, Kenzo
    Isobe, Mitsuaki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (03) : 298 - 303
  • [7] Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation
    Ciconte, Giuseppe
    de Asmundis, Carlo
    Sieira, Juan
    Conte, Giulio
    Di Giovanni, Giacomo
    Mugnai, Giacomo
    Saitoh, Yukio
    Baltogiannis, Giannis
    Irfan, Ghazala
    Coutino-Moreno, Hugo Enrique
    Hunuk, Burak
    Velagic, Vedran
    Brugada, Pedro
    Chierchia, Gian-Battista
    HEART RHYTHM, 2015, 12 (04) : 673 - 680
  • [8] Towards a tailored cryo-pulmonary vein isolation. Lessons learned from second-generation cryoballoon ablation
    Ciconte, Giuseppe
    Coulombe, Nicolas
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (07) : 420 - 425
  • [9] Circulatory Dynamics During Pulmonary Vein Isolation Using the Second-Generation Cryoballoon
    Kajiyama, Takatsugu
    Miyazaki, Shinsuke
    Watanabe, Tomonori
    Yamao, Kazuya
    Kusa, Shigeki
    Igarashi, Miyako
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Iesaka, Yoshito
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (10):
  • [10] Pulmonary vein isolation in patients with a left common pulmonary vein: Comparison between second-generation cryoballoon and radiofrequency ablation
    Yamaguchi, Masao
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Hada, Masahiro
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Iesaka, Yoshito
    JOURNAL OF CARDIOLOGY, 2019, 73 (3-4) : 292 - 298