Transit time parameter extraction for the HICUM bipolar compact model

被引:9
作者
Ardouin, B [1 ]
Zimmer, T [1 ]
Berger, D [1 ]
Celi, D [1 ]
Mnif, H [1 ]
Burdeau, T [1 ]
Fouillat, P [1 ]
机构
[1] Univ Bordeaux 1, Lab Microelect 39, UMR 5818, F-33405 Talence, France
来源
PROCEEDINGS OF THE 2001 BIPOLAR/BICMOS CIRCUITS AND TECHNOLOGY MEETING | 2001年
关键词
D O I
10.1109/BIPOL.2001.957868
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a extraction procedure for the transit time parameters of the HICUM bipolar compact model. The extraction routines use as input the measured small-signal current gain in the -20dB/decade falloff region as a function of the collector current and the collector-emitter (or collector-base) voltage. All HICUM transit time parameters are extracted in a straight forward manner, no optimisation is necessary. Especially the critical current value ICK is determined in a self consistent way.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 7 条
[1]  
DEGRAAF HC, COMPACT TRANSISTOR M
[2]   AN INTEGRAL CHARGE CONTROL MODEL OF BIPOLAR TRANSISTORS [J].
GUMMEL, HK ;
POON, HC .
BELL SYSTEM TECHNICAL JOURNAL, 1970, 49 (05) :827-+
[3]  
Kirk C. T, 1962, IRE T ELECTRON DEV, V9, P164
[4]  
LEE TZ, PRESENTATION COMPACT
[5]  
MONROY A, 1999, BCTM, P121
[6]  
SCHROTER M, 1999, IEEE T ELECT DEVICES, V46
[7]  
SCHROTER M, HICUM BIPOLAR TRANSI