Toric intraocular lens outcomes with a new protocol for IOL selection and implantation

被引:6
作者
Clark, K. D. [1 ,2 ]
机构
[1] Ophthalmol Associates Osborne Inc, 1099 Ohio River Blvd, Sewickley, PA 15143 USA
[2] Heritage Valley Surg Ctr, 1600 Coraopolis Hts Rd, Moon Township, PA 15108 USA
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2018年 / 41卷 / 02期
关键词
Astigmatism; Cataract surgery; Toric intraocular lens; Surgically induced astigmatism; Femtosecond laser-assisted; Toric marker; REFRACTIVE OUTCOMES; CATARACT-SURGERY; CLINICAL-OUTCOMES; ASTIGMATISM; EXPERIENCE;
D O I
10.1016/j.jfo.2017.08.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction. - The published literature on toric intraocular lenses (IOL) reports postoperative refractive cylinder less than or equal to 0.5 D in anywhere from 25% to 100% of implantations with both the Acrysof Toric and Tecnis Toric IOL, depending upon the article. However, the majority of articles tend to cite rates between 70% and 80%. Purpose. - The purpose was to evaluate my personal outcomes for both models of toric IOL, in terms of one-month postoperative refractive cylinder, after implementation of new methods of IOL selection, calculation and implantation. Materials and methods. - The new protocol included measurement of centroid surgically induced astigmatism by vector analysis; calculations using only the Barrett toric calculator, for which the keratometry values were obtained by optical biometry, while the keratometric axes were chosen by visual inspection of the axial topographic map; preoperative marking with the toriCAM cell phone appliance; and corneal incisions performed either manually or with a femtosecond laser. A prospective, observational study was conducted of all consecutive monofocal toric IOL implantations from September 2016 through April 2017. One-month postoperative refractive cylinder was recorded for each eye. Results. - Seventy eyes were implanted with monofocal toric IOL, 31 Acrysof (R) Toric and 39 Tecnis (R) Toric. Mean postoperative refractive cylinder was 0.48 D (0.00-1.50) for the Acrysof (R) Toric group and 0.46 D (0.00-1.00) for the Tecnis (R) Toric group. There were no statistically significant differences in postoperative refractive cylinder between IOL models or methods of incision. The percentage of eyes achieving postoperative refractive cylinder = 0.50 D ("success") was 77% for the Acrysof (R) Toric group (82% for laser-assisted and 75% for manual) and 72% for the Tecnis (R) Toric group (80% for laser-assisted and 69% for manual). Conclusion. - The implementation of the new protocol resulted in an overall surgical success rate of 77% for Acrysof (R) Toric IOL and 72% for Tecnis (R) Toric IOL (P = 0.7702). Femtosecond laser-assisted surgery resulted in higher success rates than manual surgery (82% vs. 75% for Acrysof (R) Toric and 80% vs. 69% for Tecnis (R) Toric), but these differences were not statistically significant (Acrysof (R) Toric P = 0.7336; Tecnis (R) Toric P=0.8862). Copyright (C) 2017 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 20 条
  • [1] Prediction of refractive outcomes with toric intraocular lens implantation
    Abulafia, Adi
    Barrett, Graham D.
    Kleinmann, Guy
    Ofir, Shay
    Levy, Adi
    Marcovich, Arie L.
    Michaeli, Adi
    Koch, Douglas D.
    Wang, Li
    Assia, Ehud I.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) : 936 - 944
  • [2] Visual function and patient experience after bilateral implantation of toric intraocular lenses
    Ahmed, Iqbal Ike K.
    Rocha, Guillermo
    Slomovic, Allan R.
    Climenhaga, Harold
    Gohill, Jit
    Gregoire, Alain
    Ma, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) : 609 - 616
  • [3] Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
    Davison, James A.
    Potvin, Richard
    [J]. CLINICAL OPHTHALMOLOGY, 2015, 9 : 1511 - 1517
  • [4] Toric Intraocular Lens Outcome Using the Manufacturer's Prediction of Corneal Plane Equivalent Intraocular Lens Cylinder Power
    Goggin, Michael
    Moore, Sacha
    Esterman, Adrian
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (08) : 1004 - 1008
  • [5] Prospective study of toric IOL outcomes based on the Lenstar LS 900® dual zone automated keratometer
    Gundersen, Kjell Gunnar
    Potvin, Richard
    [J]. BMC OPHTHALMOLOGY, 2012, 12
  • [6] Kirwan C, 2016, INT J OPHTHALMOL CLI, V3, P56
  • [7] Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens
    Lubinski, Wojciech
    Kazmierczak, Beata
    Gronkowska-Serafin, Jolanta
    Podbordczynska-Jodko, Karolina
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [8] Mall S, 2014, INVEST OPHTH VIS SCI, V55
  • [9] Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens
    Mazzini, Cinzia
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (02): : 48 - 56
  • [10] Milivojevic M, 2007, OPHTHALMOLOGE, P267